Operation manual
Inverta Puls IP6-2 ACT
Page 7 of 20
bottle. Connect a hose to the MIG-MAG welding device reduction valve. The recommended
gas flow is 8 – 15 liter/minute in a room without draft.
If you use an adjustable reduction valve, you can adjust a gas flow with a wing nut with
a liter scale. The device must be turned on and Gas-check function activated the welding
button must be pressed during adjustment.
It is not allowed to repair pressure valves. It is necessary to send the defective reduction val-
ves to service.
2.5 Connecting the return cable
It is necessary to connect the grounding clamp in the very vicinity of welded place. The
transfer contact must be metallic clear free of dust and color.
2.6 MMA – TIG welding connection
TIG Connection
MMA Connection
2.7 Weld area preparation
A work piece must be clean in the welding area, free of paint, metallic coat, dirt, rust, fat and
moisture. The preparation of weld must be according to technical instructions for welding.
Work piece
clamp
TIG Torch
Stick holder