Foundation: 2207, 2208, DIN 16932 German association for welding
Use for:
Miniplast 2 / 110
Miniplast 2 / 110
Miniplast 2 / 110
Miniplast 2 / 110
OD 20 - 110
Maxiplast / 501 / 900 / 955
Maxiplast / 501 / 900 / 955
Maxiplast / 501 / 900 / 955
Maxiplast / 501 / 900 / 955
OD 50 - 160
Instaweld 160
Instaweld 160
Instaweld 160
Instaweld 160
OD 50 - 160
2000 / 3000 Kombi
2000 / 3000 Kombi
2000 / 3000 Kombi
2000 / 3000 Kombi
OD 50 - 250
2500 DO 160 / 250 / 315
2500 DO 160 / 250 / 315
2500 DO 160 / 250 / 315
2500 DO 160 / 250 / 315
OD 50 - 315
ASM160 / ASM 315
ASM160 / ASM 315
ASM160 / ASM 315
ASM160 / ASM 315
OD 50 - 315
1 kp = 10 N
time to
time to
time to
time to
change-
change-
change-
change-
reach full
reach full
reach full
reach full
over
over
over
over
welding
welding
welding
welding
cool-down time
cool-down time
cool-down time
cool-down time
0,10 (PP)
time
time
time
time
pressure
pressure
pressure
pressure
pressure in
T
desired
temperature
time
pipe
pipe
SDR
bead-up
circular
heat-up
max.
time
welding
cool-
diameter
wall
force
bead
time
change-
to reach
force
down
OD
(s)
[kp]
min.
[s]
over
welding
[kp]
time
[mm]
[mm]
[daN]
[mm]
time
pressure
[daN]
[min]
[s]
[s]
Table for PP
Table for PP
Table for PP
Table for PP
The standard value for heating element temperature is 210° C +/- 10° C.
The smaller
smaller
smaller
smaller the pipe wall the higher
higher
higher
higher the temperature.
welding area
in welding area
P (N/mm²)
bead-up
bead-up
bead-up
bead-up
heat-up
heat-up
heat-up
heat-up
Additional to the given bead-up force and to the welding force the moving force of the support must be added !
[s]
[s]
280
280
280
280
6,9
41
60
0,5
173
6
7
60
12
280
280
280
280
8,6
33
74
1,0
197
6
8
74
15
280
280
280
280
10,7
26
91
1,0
227
7
10
91
18
280
280
280
280
15,9
17,6
132
1,0
292
8
14
132
26
280
280
280
280
25,4
11
204
1,5
394
11
22
204
39
280
280
280
280
30,3
9
238
2,0
433
12
26
238
46
280
280
280
280
38,3
7,4
291
2,5
493
14
33
291
57
315
315
315
315
7,7
41
75
1,0
185
6
8
75
13
315
315
315
315
9,7
33
94
1,0
213
7
9
94
16
315
315
315
315
12,1
26
116
1,0
246
7
11
116
20
315
315
315
315
17,9
17,6
168
1,0
317
9
16
168
28
315
315
315
315
28,6
11
258
2,0
420
12
24
258
44
315
315
315
315
35,2
9
310
2,0
471
14
30
310
53
Remaining under the cool-down time for up to 50% is allowed under the following conditions:
Remaining under the cool-down time for up to 50% is allowed under the following conditions:
Remaining under the cool-down time for up to 50% is allowed under the following conditions:
Remaining under the cool-down time for up to 50% is allowed under the following conditions:
••••
prefabrication under workshop conditions
••••
low additional pressure at unclamping
••••
no additional pressure during further cooling down
••••
load onto the workpieces only after being completely cooled down
••••
Join parts with wall thickness ≥15 mm
16.05.2017
Working instructions WIDOS manual machine
Page 25 / 8 of 41