5.2. How to connect the machine
•
Connect the mains plug to the local power supply (CEE 125A / 400 V / 50 Hz, right-hand
rotary field).
Observe correct mains voltages.
Lay the hydraulic and electric wires carefully (danger of stumbling).
Check whether the machine is connected right-
handedly!
For this purpose, shortly move one joystick and
check whether the turning direction of the
ventilator conforms with the arrow at the
hydraulic motor.
The left-hand rotary field damages the
hydraulic pump!
5.3. How to set the heating element temperature
Display = Display of the actual value
Push shortly button P (1), the display shows <SP>,
change desired value with buttons ▲ (3) ▼ (2).
Push shortly button P (1), the actual temperature is
displayed again (or automatic change after 30s).
During heating up to desired value, the control lamp K2
(4) is on. As soon as the desired temperature is
reached, the control lamp K2 (4) is blinking.
The ventilator is behind the lattice
Arrow shows the direction of rotation