Aquatronic 4 Ultra electric shower

E-002-A

ELECTRICAL REQUIREMENTS

The installation, supply cable and circuit 
protection must conform with BS 7671 (IEE 
wiring regulations) and be sufficient for the 
amperage required.
The following notes are for guidance only:

1

 

The shower must only be connected to a 
230-240V ac supply. If you are installing a 
shower with a kilowatt rating above 9kW, it 
is advisable to contact the local electricity 
supply company.

1.1

  The electrical rating of the shower is shown 

on the rating label 

(Fig.3)

 within the unit.

2

 

 Before making any sort of electrical 
connection within the installation make sure 
that no terminal is live. If in any doubt, 
switch off the whole installation at the mains 
supply and remove the correct fuse.

3

 

The shower must be connected to its own 
independent electrical circuit. IT MUST NOT 
be connected to a ring main, spur, socket 
outlet, lighting circuit or cooker circuit.

3.1

  The electrical supply must be adequate for 

the loading of the unit and existing circuits.

4

 

Check your consumer unit (main fuse box) 
has a main switch rating of 80A or above 
and that it has a spare fuse way which will 
take the fuse or Miniature Circuit Breaker 
(MCB) necessary for the shower 

(Fig.4).

4.1

  If your consumer unit has a rating below 

80A or if there is no spare fuse way, then the 
installation will not be straightforward and 
may require a new consumer unit serving 
the house or just the shower.

4.2

  You will need to contact the local electricity 

company. They will check the supply and 
carry out what is necessary. 

5

 

For close circuit protection DO NOT use a 
rewireable fuse. Instead use a suitably rated 
Miniature Circuit Breaker (MCB) or cartridge 
fuse

(see Table A).

5.1

  A 30mA residual current device (RCD) must 

be installed in all UK electric and pumped 
shower circuits. This may be part of the 
consumer unit or a separate unit.

6

 

A 45 amp double pole isolating switch with 
a minimum contact gap of 3 mm in both 
poles must be incorporated in the circuit.

6.1

  It must have a mechanical indicator showing 

when the switch is in the OFF position, and 
the wiring must be connected to the switch 
without the use of a plug or socket outlet.

6.2

  The switch must be accessible and clearly 

identifiable, but out of reach of a person 
using a fixed bath or shower, except for the 
cord of a cord operated switch, and should 
be placed so that it is not possible to touch 
the switch body while standing in a bath or 
shower cubicle. It should be readily 
accessible to switch off after using the 
shower.

7

 

Where shower cubicles are located in any 
rooms other than bathrooms, all socket 
outlets in those rooms must be protected by 
a 30mA RCD.

8

 

The current carrying capacity of the cable 
must be at least that of the shower circuit 
protection

(see Table B).

8.1

  To obtain full advantage of the power 

provided by the shower, use the shortest 
cable route possible from the consumer unit 
to the shower.

8.2

  It is also necessary to satisfy the 

disconnection time and thermal constraints 
which means that for any given combination 
of current demand, voltage drop and cable 
size, there is a maximum permissible circuit 
length.

9

 

The shower circuit should be separated from 
other circuits by at least twice the diameter 
of the cable or conduit.

9.1

  The current rating will be reduced if the 

cabling is bunched with others, surrounded 
by thermal loft or wall insulation or placed in 
areas where the ambient temperature is 
above 30°C. Under these conditions, 
derating factors apply and it is necessary to 
select a larger cable size.

9.2

In the majority of installations, the cable 
will unavoidably be placed in one or more 
of the above conditions. This being so, it 
is strongly recommended to use a 
minimum of 10mm cabling throughout 
the shower installation.

9.3

  In any event, it is essential that individual 

site conditions are assessed by a competent 
electrician in order to determine the correct 
cable size and permissible circuit length.

Meter

Incoming

supply

fuse

Meter

tails

Consumer

unit

Pull cord

isolating switch

Shower

unit

Fuse or

MCB

RCD

(can be part of

consumer unit)

80A or 100A

main switch

Shepperton Park,

Triton Road, Nuneaton,

Warwickshire, CV11 4NR

Table A

MCB

30/32A

32A
40A
40A
40A

40/45A

45A

cartridge

fuse

30A
35A
35A
45A
45A
45A
45A

unit

rating

7.0kW
7.5kW
8.0kW
8.5kW
9.0kW
9.5kW

10.5kW

CIRCUIT PROTECTION

Fig.

 Schematic of installation circuit

Fig.

W-006-A

WARNING!

THIS APPLIANCE MUST BE EARTHED

E-002-A

ELECTRICAL REQUIREMENTS

The installation, supply cable and circuit 
protection must conform with BS 7671 (IEE 
wiring regulations) and be sufficient for the 
amperage required.
The following notes are for guidance only:

1

 

The shower must only be connected to a 
230-240V ac supply. If you are installing a 
shower with a kilowatt rating above 9kW, it 
is advisable to contact the local electricity 
supply company.

1.1

  The electrical rating of the shower is shown 

on the rating label 

(Fig.3)

 within the unit.

2

 

 Before making any sort of electrical 
connection within the installation make sure 
that no terminal is live. If in any doubt, 
switch off the whole installation at the mains 
supply and remove the correct fuse.

3

 

The shower must be connected to its own 
independent electrical circuit. IT MUST NOT 
be connected to a ring main, spur, socket 
outlet, lighting circuit or cooker circuit.

3.1

  The electrical supply must be adequate for 

the loading of the unit and existing circuits.

4

 

Check your consumer unit (main fuse box) 
has a main switch rating of 80A or above 
and that it has a spare fuse way which will 
take the fuse or Miniature Circuit Breaker 
(MCB) necessary for the shower 

(Fig.4).

4.1

  If your consumer unit has a rating below 

80A or if there is no spare fuse way, then the 
installation will not be straightforward and 
may require a new consumer unit serving 
the house or just the shower.

4.2

  You will need to contact the local electricity 

company. They will check the supply and 
carry out what is necessary. 

5

 

For close circuit protection DO NOT use a 
rewireable fuse. Instead use a suitably rated 
Miniature Circuit Breaker (MCB) or cartridge 
fuse

(see Table A).

5.1

  A 30mA residual current device (RCD) must 

be installed in all UK electric and pumped 
shower circuits. This may be part of the 
consumer unit or a separate unit.

6

 

A 45 amp double pole isolating switch with 
a minimum contact gap of 3 mm in both 
poles must be incorporated in the circuit.

6.1

  It must have a mechanical indicator showing 

when the switch is in the OFF position, and 
the wiring must be connected to the switch 
without the use of a plug or socket outlet.

6.2

  The switch must be accessible and clearly 

identifiable, but out of reach of a person 
using a fixed bath or shower, except for the 
cord of a cord operated switch, and should 
be placed so that it is not possible to touch 
the switch body while standing in a bath or 
shower cubicle. It should be readily 
accessible to switch off after using the 
shower.

7

 

Where shower cubicles are located in any 
rooms other than bathrooms, all socket 
outlets in those rooms must be protected by 
a 30mA RCD.

8

 

The current carrying capacity of the cable 
must be at least that of the shower circuit 
protection

(see Table B).

8.1

  To obtain full advantage of the power 

provided by the shower, use the shortest 
cable route possible from the consumer unit 
to the shower.

8.2

  It is also necessary to satisfy the 

disconnection time and thermal constraints 
which means that for any given combination 
of current demand, voltage drop and cable 
size, there is a maximum permissible circuit 
length.

9

 

The shower circuit should be separated from 
other circuits by at least twice the diameter 
of the cable or conduit.

9.1

  The current rating will be reduced if the 

cabling is bunched with others, surrounded 
by thermal loft or wall insulation or placed in 
areas where the ambient temperature is 
above 30°C. Under these conditions, 
derating factors apply and it is necessary to 
select a larger cable size.

9.2

In the majority of installations, the cable 
will unavoidably be placed in one or more 
of the above conditions. This being so, it 
is strongly recommended to use a 
minimum of 10mm cabling throughout 
the shower installation.

9.3

  In any event, it is essential that individual 

site conditions are assessed by a competent 
electrician in order to determine the correct 
cable size and permissible circuit length.

Содержание Aquatronic 4 Ultra

Страница 1: ...Installation and operating instructions 2180702B July 2008 Installers please note these instructions are to be left with the user Aquatronic 4 Ultra electric shower ...

Страница 2: ... 11 Commissioning 12 Replacing the cover 14 Operating the shower 15 Operating functions 17 Cleaning 18 Instructions for installers and service engineers only 19 Spare parts 20 Fault finding 21 22 Guarantee service policy etc rear cover CONTENTS Page To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation ...

Страница 3: ...operate This product is not suitable for mounting into steam rooms or steam cubicles PLUMBING The plumbing installation must comply with Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS 6700 The supply pipe must be flushed to clear debris before connecting to the shower unit DO NOT sold...

Страница 4: ...ounted on a flat surface which covers the full width and length of the backplate It is important that the wall surface is flat otherwise difficulty may be encountered when fitting the cover and subsequent operation of the unit may be impaired The following points will help you understand how the shower operates a The electric heating elements operate at a constant rate at your chosen power setting...

Страница 5: ...a 6 Wall screw fixing 7 Terminal block 8 Power PCB 9 Stabilising valve 10 Solenoid valve 11 Guide pockets 12 Can and element assembly 13 Thermal cut out main 14 Earth connection 15 Pressure relief device 16 Outlet temperature regulator 17 Trimplate Inside cover fig 2 19 Cover tags 20 Control PCB 21 Neon bracket 22 Start Stop switch Other items Screw fixing kit Instructions guarantee etc Note Not a...

Страница 6: ...ng 7 0kW 7 5kW 8 0kW 8 5kW 9 0kW 9 5kW 10 5kW CIRCUIT PROTECTION Fig 4 Schematic of installation circuit Fig 3 W 006 A WARNING THIS APPLIANCE MUST BE EARTHED E 002 A shower with a kilowatt rating above 9kW it is advisable to contact the local electricity supply company 1 1 The electrical rating of the shower is shown on the rating label Fig 3 within the unit 2 Before making any sort of electrical ...

Страница 7: ... event it is essential that individual site conditions are assessed by a competent electrician in order to determine the correct cable size and permissible circuit length E 002 A carry out what is necessary 5 For close circuit protection DO NOT use a rewireable fuse Instead use a suitably rated Miniature Circuit Breaker MCB or cartridge fuse see Table A 5 1 A 30mA residual current device RCD must ...

Страница 8: ...kPa 10 bar If in any doubt the pressure should be checked Note If the stated flow rate is not available it may not be possible to achieve optimum per formance from the unit throughout the year During periods of high ambient temperatures it may be necessary to select a low power setting to achieve your preferred shower temperature The water supply can be taken from a cold water storage cistern prov...

Страница 9: ...t If installing onto a tiled wall always mount the unit on the surface of the tiles NEVER tile up to the unit Refer to fig 6 for the correct siting of the shower Position the unit where it will not be in direct contact with water from the showerhead Position the shower unit vertically Allow enough room between the ceiling and the shower to access the cover top screws Leave enough space between the...

Страница 10: ...ired then a small area will need to be cut out in the backplate fig 9 If installing a feed pipe from the rear bottom or side the centre of the inlet valve to the wall surface is 21 mm fig 10 Note If entry is from the rear the nut of the compression fitting will be partially behind the surface of the wall fig 10 This area must be left clear when plastering over the pipework in order to make the nut...

Страница 11: ... from the wall Hook the backplate over the top and bottom screws and fit the centre fixing screw into position Do not fully tighten the screws at this stage as the fixing holes are elongated to allow for out of square adjustment after the plumbing connections have been completed T00424 P1 27 21 00 2A IN L E T POM GF30 P1 27 21 00 2A IN L E T Fig 11 Fig 10 ...

Страница 12: ...o remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris to waste Procedure Turn off water supply either at the mains stopvalve or the isolating stopvalve Connect the mains water supply to the inlet of the shower via 15 mm copper stainless steel or plastic pipe using a 15 mm x 15 mm brass el...

Страница 13: ...r must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by embedding in the wall in accordance with current IEE regulations The use of connections within the unit to supply power to other equipment i e extractor fans pumps etc will invalidate the guarantee DO NOT switch on the e...

Страница 14: ... locate the cover onto the backplate and make sure the wires are not trapped Guide the cover into position so that the control spindle locates correctly minor adjustment may be necessary to align the control and spindle Should any difficulty arise recheck the points above While applying slight pressure to the front cover secure in position with the three retaining screws Fit the flexible hose to t...

Страница 15: ...times to release any trapped air from within the unit Once the flushing out has been completed switch off the electricity to the shower at the isolating switch The water will cease to flow Unscrew the top and bottom cover retaining screws and lift the cover from the backplate Attached to the control and display PCB inside the cover is a 10 way ribbon cable The ribbon cable connector must be plugge...

Страница 16: ... temperature control on the cover fully clockwise to the minimum flow position fig 19 Offer the cover to the unit Carefully locate the cover tags into the guide pockets on the backplate and make sure the wires are not trapped Guide the cover into position so that the knob spindle locates correctly minor adjustment may be necessary to align the knob and spindle Should any difficulty arise recheck t...

Страница 17: ...nomy setting uses less energy when the ambient mains water temperature is high during hot months Note When starting the shower the default setting is high The upper button alternates between the two settings Press the button once to select the Economy setting press the button again to reselect High Temperature adjustment at this setting is via the temperature control The lower button is for COLD w...

Страница 18: ...ure to the same position on high To decrease the shower temperature Turn the temperature control anti clockwise this will increase the flow of water through the shower To increase the shower temperature Turn the temperature control clockwise this will decrease the flow of water through the shower Note It is advisable to be certain that the showering temperature is satisfactory by testing with your...

Страница 19: ...ator only is lit Phased shutdown In use when the Start stop button is pressed power is switched off to the elements Water will continue to flow for a few seconds flushing out any remaining hot water This makes sure the next immediate user will not receive a slug of hot water if standing under the showerhead when starting the shower Temperature limiter During normal operation if an overheat tempera...

Страница 20: ...isit from a qualified engineer to determine the nature of the fault and replace the safety device once the unit has been repaired CLEANING W 007 A WARNING DO NOT use abrasive or aggressive cleaning products when cleaning the shower as they may damage the unit G 004 A Triton Showers recommend that all products are cleaned using warm soapy water Do not use abrasive or aggressive chemical cleaning pr...

Страница 21: ...er or service engineer IMPORTANT Before servicing switch off both the electricity supply and water supply at the mains The inlet filter is situated in the side of the inlet pipe fig To gain access to the filter remove the trimplate and then unscrew the retaining nut from the side of the inlet pipe When cleaning the wire mesh filter do not use a sharp object as it will cause damage It is preferable...

Страница 22: ...assembly P12120801 Heater can assembly 9 5kW P12120705 Pressure relief device PRD 82800450 Cover assembly White including Control PCB Start Stop switch LED assemblies S22730600 Cover assembly Chrome including Control PCB Start Stop switch LED assemblies S22730602 Start Stop switch assembly 82301360 LED assembly P12130901 Outlet pipe assembly S12711003 Trimplate white 7053638 Trimplate Grey 7053784...

Страница 23: ...rvice Reduce flow rate via temperature control Is water supply mains or tank fed If tank fed replumb to mains water supply or see 4 2 4 If mains fed make sure that the mains stopvalve is fully open and there are no other restrictions in the supply while shower is in use or see 4 2 4 Fit pump to give minimum pressure see rating label Contact Customer Service for advice Readjust flow rate to give re...

Страница 24: ...witch Replace solenoid valve Have unit checked Ring Customer Service 4 2 3 4 2 4 4 3 1 4 3 2 4 4 1 5 1 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 1 7 2 1 7 3 1 required see rating label Reduction in ambient water temperature Electrical malfunction or safety cut out operated Water pressure has dropped below minimum required Blocked showerhead Twisted blocked flexible shower hose Showerhead not removed while com...

Страница 25: ...Aquatronic 4 Ultra electric shower 23 ...

Страница 26: ...Aquatronic 4 Ultra electric shower 24 ...

Страница 27: ...Aquatronic 4 Ultra electric shower 25 ...

Страница 28: ...f a complaint occurring the following procedure should be followed 1 Telephone Customer Service on 0844 980 0735 having available the model number and power rating of the product together with the date of purchase 2 Customer Service will be able to confirm whether the fault can be rectified by either the provision of a replacement part or a site visit from a qualified service engineer 3 If a servi...