background image

 

 

36

 / 

65

   

www.wireless-tek.com

 

 

 

Pic 36    Qos apply page 

 

2

Qos schedule page 

 

Figure 37 shows the Qos scheduling page, the user can use this page to configure the 

port QOS scheduling type, but also can modify the queue priority. The list is the real-time 

display port scheduling mode and the weight value of each queue. 

Содержание WI-PMS310GF-UPS

Страница 1: ...tate field 10 WEB PAGE INTRODUCTION 11 1 Login dialog box 11 2 Main page 11 3 System Configuration 12 4 Port configuration 20 5 MAC Bind 27 6 MAC filter 29 7 VLAN configuration 30 8 SNMP configuration...

Страница 2: ...gement features Moreover the switch also comes equipped with 2 gigabit SFP slots expanding your network flexibly WI PMS310GF UPS UPS system is designed specifically for 24VDC POE equipment like that f...

Страница 3: ...ller and battery controller for charge and dis charge battery circulatory from solar Panel and AC Restart AP via PoE managed page remotely Up to 4K QVLANs simultaneously Link Aggregation Control Proto...

Страница 4: ...00BASE TX 1000Base T UTP category 5 5e 6 or above cable maximum 100m 1000BASE X MMF SMF 1000Base L X 62 5 m 50 m MM 2m 550m or 10 m SMF 2m 5000m Fan Quantity Fanless Power Consumption 150W max with Po...

Страница 5: ...o access Users can easily access the switch from anywhere on the network Users can use the familiar Netscape Communicator and Microsoft Internet Explorer and other browsers to access the WEB page of t...

Страница 6: ...ured on the switch By default the interface IP address of the switch s VLAN1 is 192 168 0 1 The subnet mask is 255 255 255 0 A host computer with a Web browser installed has been connected to the netw...

Страница 7: ...om Pic 1 WEB login page for browsing session 4 WEB page basic composition Figure 2 The WEB page consists of three parts the title page the navigation tree page and the main page Pic 2 Switch Web page...

Страница 8: ...left of each page displaying the nodes of the Web page in a tree and the user can easily find the WEB page to be managed According to the different functions of the page will be divided into different...

Страница 9: ...in the table When you select a value in the entry field the corresponding information for that row is displayed on the first row and only the row can be edited which is also called the active row When...

Страница 10: ...column of the table that have a status field as shown in Figure 6 where the field shows the row state Since all row state changes are processed internally the status field is read only Once all the do...

Страница 11: ...enters the user name and password in the corresponding field and then clicks the OK key to log in to the Web server of the switch Password is case sensitive anonymous user password can be set up to 16...

Страница 12: ...ptor identification number indicates the identity of the system in network management The system version number shows the version number of the current software used by the switch The number of networ...

Страница 13: ...on the user can modify the system contact Pic 9 Basic information page 2 Serial port configuration page Figure 10 shows the serial port configuration page which shows the serial port baud rate and oth...

Страница 14: ...time through this page users can configure multiple users the switch default no multi user that is the default does not enable multi user management functions then login does not require multi user u...

Страница 15: ...sts can access the switch of these three services If the administrator for security do not want to provide other users one or several of these services can shut down one or more of these services Admi...

Страница 16: ...figuration page 5 SNTP configuration page Figure 13 shows the SNTP configuration page where the administrator can configure and view the system clock through configuration of the page Pic 13 SNTP conf...

Страница 17: ...Configuration file page This page allows the user to view the initial configuration of the system The initial configuration is actually the configuration file in the FLASH When there is no configurat...

Страница 18: ...lect the directory path of the uploaded profile or image file on the PC Click the upload key to upload the configuration file or image file The configuration file suffix must be cfg The image file mus...

Страница 19: ...system reset page through this page users to restart the switch When you click the restart button a dialog box will pop up prompting you if the user is sure to restart the switch If OK press the OK ke...

Страница 20: ...basic information of all ports To set a specific port select the appropriate port name in the drop down menu for the user s port Port status defaults to up and you can select the down in the drop down...

Страница 21: ...tion page Figure 19 shows the port statistics information page To view a particular port select the appropriate port name in the drop down menu for the user s port Users can view the statistics of the...

Страница 22: ...ntrol page This page is used to configure suppression the broadcast packets multicast packets and DLF packets on the port Select the port to be configured from the drop down bar of the port On and off...

Страница 23: ...on key to take effect If the port is not configured with bandwidth control it is displayed as off The corresponding cancel key is used to cancel the bandwidth control of the sending data packet The re...

Страница 24: ...24 65 www wireless tek com Pic 22 Port rate limit page 6 Protected port page Figure 23 shows the protected port page This page is used to configure the protection port Pic 23 Protected port page...

Страница 25: ...tion the user needs to select a trunk group ID from ID 1 to 8 The user clicks the corresponding trunk group ID in the list box The information of the trunk group is displayed in the group member port...

Страница 26: ...Each trunk group can configure its own port aggregation method Pic 25 Port trunking configuration page 9 Port mirror configuration page Figure 26 shows the Port mirror configuration page This page all...

Страница 27: ...ed NOT_TRANSMIT indicates that the packet is canceled Of the packet NEITHER that cancel the monitor received and sent the packet that is to cancel the listening port Pic 26 Port mirror configuration p...

Страница 28: ...e 28 shows the MAC binding auto conversion page This page is used to implement the port automatically bind MAC address Displays the dynamic MAC address and the VLAN of the port in the two tier hardwar...

Страница 29: ...tered MAC address The VLAN ID entry is used to enter the VLAN to which the MAC address belongs Pic 29 MAC filter configuration page 2 MAC auto filter page Figure 30 shows the MAC filter automatically...

Страница 30: ...e and port members Select a vlan from the drop down box and the list will display information with a VID greater than 30 vlan for that vlan But if all the vlan no more than 30 regardless of the drop d...

Страница 31: ...s generated by the system according to the VLAN ID and can not be modified Click the Apply key and the list box displays the VID and VLAN name of the VLAN created by the user The switch creates VLAN 1...

Страница 32: ...ntagged member of VLAN1 and the default VLAN of the port is 1 The VLAN mode of the trunk port is Trunk mode In this VLAN mode the default port is the tagged member of VLAN1 and the default VLAN of the...

Страница 33: ...MP configuration 1 SNMP community configuration page Figure 34 shows the SNMP Community Configuration page which allows the user to configure the name of the switch and the read and write permissions...

Страница 34: ...e TRAP protocol package When configuring an entry the name is used to enter the TRAP name The IP address is used to enter the destination address The SNMP version is used to select the version of the...

Страница 35: ...page 9 Qos configuration 1 Qos apply page Figure 36 shows the Qos application page the user can use this page to configure the port QOS type but also can modify the default user priority The list is t...

Страница 36: ...s schedule page Figure 37 shows the Qos scheduling page the user can use this page to configure the port QOS scheduling type but also can modify the queue priority The list is the real time display po...

Страница 37: ...Figure 38 shows the ACL standard IP configuration page You can use this page to create a rule base for ACL standard IP The user can select an ACL group number range between 1 99 or 1300 1999 to creat...

Страница 38: ...a rule number When a rule in a rule group is deleted the other rules are not changed and the system automatically assigns a rule to a rule group Sort If you want to delete the entire rule group you c...

Страница 39: ...p the system automatically gives the rule a rule number When a rule in a rule group is deleted the other rules are not changed and the system automatically assigns a rule to a rule group Sort If you w...

Страница 40: ...rule number When a rule in a rule group is deleted the other rules are not changed and the system automatically assigns a rule to a rule group Sort If you want to delete the entire rule group you can...

Страница 41: ...5 When a user configures a rule each rule must have a filtering mode allow or deny When a user creates a rule in a rule group the system automatically gives the rule a rule number When a rule in a rul...

Страница 42: ...ACL group to the port hardware logic to enable the port to perform ACL filtering on the received packets according to these rules When selecting an ACL group on a port you can select the IP standard...

Страница 43: ...VLAN interface configuration page You can configure the VLAN interface remove the VLAN interface configure the IP address of the interface delete the IP address of the interface and view the interface...

Страница 44: ...IP address and MAC address The MAC address must be a unicast MAC address and then click the Add key When a user deletes an ARP entry you can choose to delete an ARP entry from one IP address delete an...

Страница 45: ...guration page Figure 46 shows the host static routing configuration page the user can add and delete the host static route of the switch By default no static route is configured on the switch You can...

Страница 46: ...entication type and shared secret key Before using the Tacacs function you must enable the Tacacs function which is configured by default Configure the IP address of the Tacacs server which must be se...

Страница 47: ...1812 the user generally do not need to modify this field Whether to start billing the default is to start when doing the authentication and billing to start billing Billing UDP port the default value...

Страница 48: ...function will make the user more reliable when using authentication and billing but will slightly increase the traffic to the network Set the re authentication interval only in the case of re authenti...

Страница 49: ...ode and the maximum number of hosts that can be configured You can also view the 802 1x configuration of each port The 802 1x port mode includes four types N A status Auto state Force authorized statu...

Страница 50: ...of hosts that can be accessed by the port is 256 and the user can modify this field to support up to 256 5 802 1x user auth information page Figure 51 shows the 802 1x user auth information page You...

Страница 51: ...igure 52 shows the MSTP global configuration page You can configure global MSTP parameters through this page Pic 52 MSTP global configuration page 2 MSTP port configuration page Figure 53 shows the MS...

Страница 52: ...wireless tek com Pic 53 MSTP port configuration page 3 MSTP port information page Figure 54 shows the MSTP port information page You can view the port MSTP status on this page Pic 54 MSTP port informa...

Страница 53: ...ooping global configuration page You can enable IGMP snooping on this page Pic 55 IGMPsnooping global configuration page 2 Multicast group information page Figure 56 shows the multicast group informat...

Страница 54: ...gure 57 shows the GMRP global configuration page Users can enable GMRP through this page Pic 57 GMRP global configuration page 2 GMRP port configuration page Figure 58 shows the GMRP port configuratio...

Страница 55: ...reless tek com Pic 58 GMRP port configuration page 3 GMRP state machine page Figure 59 is the GMRP state machine page Users can view GMRP s state machine information from this page Pic 59 GMRP state m...

Страница 56: ...uch as fe1 1 ge1 1 Alternate port EAPS second port Control vlan EAPS ring control vlan the value of 2 4094 Protected vlan EAPS ring protection vlan Hello time interval Hello message to send the time i...

Страница 57: ...can configure the RMON statistics group through this page Select a port from the drop down list to view configure the RMON statistics group configuration for that port If the index number is 0 the co...

Страница 58: ...s 0 the correct index number in the range of 1 to 100 the interval the request Buckets and the owner is optional You can configure the RMON history group for the port Interval refers to the time inter...

Страница 59: ...ws the sampled value when the last alarm was issued The event index refers to the index number of the RMON event group and must be configured in advance Pic 64 RMON alarm group configuration page 4 RM...

Страница 60: ...ackets sent by the device on the receiving device The effective time range is 1 4096 seconds The default configuration is 180 seconds Configure the interval for sending NDP packets the valid time rang...

Страница 61: ...tion page the user can configure the cluster through this page and view the cluster member table The information that can be set includes the functions of enabling the cluster configuring the manageme...

Страница 62: ...member table you can add a member device or add a candidate device to a member device depending on the role Pic 68 cluster configuration page 19 ERPSc configuration 1 EAPS configuration page Figure 69...

Страница 63: ...default is 5 Protocol packet transmission time Configure the sending time of the ERPS ring protocol packets 1 10 in seconds the default is 5 Enable ERPS ring Turn the ERPS ring on or off Force to swi...

Страница 64: ...uration page You can configure POE device total power to be updated POE single port power to be updated POE on or off This page allows you to view information about the current POE device POE port Sel...

Страница 65: ...led management 1 24 control function enable or disable Pic 73 48V 802 3af at POE schedule configuration page 3 POE Online detection system to be updated Used to turn on or off the online detection dev...

Отзывы: