Advanced Bulk System
23
Maintenance Checklist:
EVERY 3 MONTHS:
4
Check Spin-on Filters.
4
Check Desiccant Air Breathers.
4
Confirm with your fluid supplier how frequently your fluid should be re-circulated to maximize fluid life. Should a Re-Circulation (“Kidney-Loop”) cycle
be recommended, run a recirculation cycle for the suggested times set out in the Tank Re-Circulation (“Kidney-Loop”) Cycle Time Guide in the Data
Tables section (page 35).
• Put the valves in the “Re-Circulate” configuration (left “DOWN”, right “UP”).
• Run each filled Bulk Tank for suggested time.
EVERY 6 MONTHS:
4
Replace Spin-on Filters as required.
4
Replace Desiccant Air Breathers as required (orange beads will turn dark green indicating the filter is used).
4
Check the batteries on any installed over-fill alarms. Batteries should be changed once per year.
4
Inspections:
• Inspect all hoses for cracks or kinks.
• Inspect all hose fittings for cracks or leaks.
• Inspect and tighten all bolts.
4
Clean external surfaces: (Use an environmentally friendly cleaning/degreasing fluid and warm water. Rinse completely before replacing.)
• Remove drip-pans from beneath the faucets, clean the entire grate and flush the pan.
• Remove faucet nozzles by unscrewing, clean heads and o-rings.
See Figure 18 (for standard faucets).
If your system contains a fire safe valve (see your specification sheet for details), the valve can be closed by releasing the fusible link lead clip on the top
of the valve. In the event of a fire, the lead clip will melt, forcing the valve to automatically close and secure your fluid.
See Figure 17.
FIGURE 17:
Fire Safe Isolation Valve in the Open Position