5. INSTALLATION
CAUTION!
Personal Protective Equipment (“PPE”) should be worn when installing and operating this system.
System Operating Pressure should NEVER exceed 300 PSI. System operating pressures can be regulated
by adjusting pump bypass relief valves located on pump heads to suit specific lubricant viscosities and
temperatures.
System SHOULD NOT be operated in a location with an ambient room temperature less than 60°F/15°C
Contact the manufacturer for more information relating to service in cold environments.
STEP 1.
The system is delivered pre-assembled, packaged, and marked “Pod-1”, “Pod-2” etc. depending on the specific customized system. This will
indicate the respective Pod’s position within the system from left to right, when viewed from the front.
STEP 2.
Locate Pod-1 and remove and appropriately dispose of the freight packaging.
STEP 3.
Using a suitable hand pallet truck, position Pod-1 into its service position, ensuring that there is at least 18" of free clear space at the rear and
18" either end of the system. This will enable personnel to access the system for service work.
See Figure 4.
FIGURE 4:
Minimum Clearance Requirements