4. INSTALLATION AND SETUP
Tools, Materials, and Personnel Requirements:
•
A minimum of two people are recommended to complete this install.
•
Electrical hook-ups and installation should be completed by your authorized electrical personnel in accordance with all local and federal laws and
regulations.
•
A hand pallet truck is required to move each Pod into position.
•
3/4" wrench for system leveling/jacking bolts.
•
2-3/8" wrench to tighten Fluid Level Gauge.
•
Spin-on filter wrench.
•
Personal Protective Equipment (“PPE”) should be worn when installing and operating this system.
Determine Placement:
1. The system should be installed indoors on a flat, level surface with sufficient load-bearing capacity to support the total system weight.
See Table 5
on page 35.
2. Each electrical motor requires a separate power outlet. See your specification sheet (or system supply quotation) for electrical requirement details.
Give consideration to whether more than one pump could be running at the same time, in which case it is recommended that each power outlet be
wired with independent circuits. CONSULT WITH AN AUTHORIZED AND TRAINED ELECTRICIAN.
3. BEFORE beginning installation, determine where your system will be installed and ensure sufficient power outlets have been installed at the rear of
the system, positioned behind where the motors will be located. Each power outlet should be equally spaced along the wall and be placed approxi-
mately 12" up from floor level.
IMPORTANT:
• It is important to note the effect of the ambient temperature in which the system is placed for operation. System room
temperature should be in the range of 60°F (15°C) TO 80°F (26°C) with optimum room temperature being 70°F (21°C).
For ambient temperatures below 60°F (15°C) consult the manufacturer or your supplier for the supply of electric blan-
ket heaters for oil barrels, pails and bulk tanks to ensure stability of lubricant viscosity, condition and system perfor-
mance.
• Temperatures less than (<60°F / 15°C) can result in lubricant viscosity increasing above the rated ISO Code you speci-
fied at the time of order. Such adverse viscosity changes can cause higher system operating pressures than those set
at the factory.
• System operating pressure should never exceed 300 PSI as this can cause a gasket failure on the spin-on filter result-
ing in a high pressure oil leak. Normal system operating pressure should be less than 240 PSI. Operating pressures
above 240 PSI will necessitate adjustment of the pump pressure relief bypass valve located on the pump head.
•
Contact the manufacturer for more information prior to commissioning the system if the ambient room temperature will
ever fall below 60°F (15°C).