Advanced Bulk System
15
5. INSTALLATION
IMPORTANT:
• Per the manufacturer’s recommendation, write the installation date of the Spin-on Filter on the provided sticker located
on the filter. The first filter should be replaced after the first 50 hours of system service. Subsequent filters should be
replaced per the instructions in the
Maintenance Section of this manual on page 22.
STEP 19.
Install the Static Discharge Grounding Reel securely to the front face of the Tank Pod (Pod-1) frame using the threaded holes provided in the
frame and the mounting bolts supplied with the reel.
STEP 20.
Pull the grounding cable out to determine if the tension is sufficient for the intended use.
a.
If additional tension is needed, apply a wrench to flats on the mainspring shaft, rotating counter-clockwise until the desired tension
is reached.
b.
If mainspring tension is too high, it may be decreased by depressing the tension lock spring on the opposite side of reel.
DO NOT
remove
more tension than desired. If too much tension is removed, increase tension as described above.
STEP 21.
Install the dispensing faucets supplied with your system into the threaded ports provided on the front face of the control panel.
Use of appropriate thread sealing paste is recommended on threaded joints.
6. ELECTRICAL INSTALLATION
WARNING!
Failure to follow system installation, safety and operating instructions may result in severe injury or death,
damage to plant and equipment and void manufacturer warranties.
The following instructions should be carried out by a
trained and authorized
electrician or electrical
personnel in accordance with your local and federal regulations and safety procedures.
Always
ensure
the system is appropriately grounded to earth utilizing the grounding lugs provided at the rear base of the
system, together with relevant grounding equipment as specified and installed by your authorized electrical
personnel.
The system should be grounded before use.
Grounding Lugs are provided at the rear base of the system
on the inner face of the frame uprights. At the rear of the system, locate the power supply cord(s) coming
from the electrical motor/s.
STEP 22.
Plug the power cords into the individual wall outlets as designated in the specification sheet.
NOTE:
There will be one (1) power supply cord for each motor and each will be labeled to correspond to its related
motor/tank.