background image

WHITEHALL MANUFACTURING

 • P.O. BOX 3527 • City of Industry, CA 91477-0527 U.S.A

Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

Instructions for Operation and Care of Thermo-Therapy Dry Heat Therapy

3

Thermo-Electric’s  Thermo  Therapy  Units  are  designed 
to  safely  provide  the  benefits  of  Celstim

®

  -  a  specially 

processed,  granulated,  sterilized  cellulose  successively 
filtered  to  removed  the  maximum  number  of  fines-  being 
held  in  animated  suspension  and  gently  and  warmly 
massaging a patient’s hand, wrist, arm or foot, ankle, leg.

Model TT-101  is  designed  principally  for  home  use  –  but 
can be used in small clinics and offices – and is constructed 
with a variable speed blower, variable heat, front and top 
treatment ports and obtains its air supply through a bottom 
located filtered and sound baffled fresh air inlet. 

Although the unit is small and compact and the opportunity 
for  noise  control  is  limited,  the  unit  operates  only  slightly 
louder than our larger units because of strategically placed 
sound baffles.

Model TT-101L is of the same construction as the TT-101, 
but possesses a treatment chamber that is 3” deeper and 2” 
longer than the TT-101 and is designed for the small clinic 
or office. 

An  optional  stand  is  available  for  both  the  TT-101  and 

 

TT-101L models. 

Model TT-202  is  floor  mounted. TT-202  has  dual  blowers 
and speed controls as well as dual top and rear treatment 
ports. The unit has permanently installed rubber pads along 
the top to provide patient under arm comfort. 

All Thermo-Theraphy Units have an elevated top edge on 
3  sides  to  best  capture  and  prevent  the  spread  of  errant 
Celstim®.

The  controls  located  on  the  control  panel  are  of  rugged, 
long lasting “mechanical” design and any single controlling 
component can individually and replaced. 

On  all  models,  the  air  distribution  assembly  is  separated 
from  the  patient  by  a  patient  protection  grill  remaining 
at  nearly  the  same  temperature  as  the  Celstim  and  also 
eliminates any shocking from static electricity. 

The  rear  upper  panels  can  also  be  removed  by  qualified 
service personnel and the blowers, heating element, etc., 
are easily and quickly removed and replaced in the event 
of  a  malfunction.  In  fact,  the  blower(s)  are  mounted  on  a 
board  which  with  the  removal  of  one  screw  slides  out  of 
immediate access.

For  additional  safety,  the  heating  element’s  compartment 
is lined with metal and dual safety switches set specifically 

not to exceed 275°F (135°C). Also, a fourth thermostat is 
located behind the control panel which mimics the control 
thermostat and assures a maximum Celstim temperature of 
125-128°F (51.7-53.3°C).

So,  congratulations  on  your  new  Thermo-Therapy  Unit  – 
we welcome your comments, recommendations and/or any 
questions. 

Содержание Thermo Therapy TT-202

Страница 1: ...ty of Industry CA 91744 0527 U S A 800 782 7706 626 968 6681 www whitehallmfg com Whitehall Manufacutring is a Member of Acorn Engineering s Family of Companies 6900 101 000 May 2009 Dry Heat Theraphy Models TT 101 TT 101L and TT 202 TT 101 TT 101L TT 202 ...

Страница 2: ...d Care of Thermo Therapy Dry Heat Therapy 2 Introduction 3 TT 101 Product Information 4 TT 101L Product Information 5 TT 202 Product Information 6 Requirements for Installation 7 Receiving Instructions 7 Specifications 7 Symbol Instructions 8 Instructions for Use and Operating Controls 9 Maintenance of the Unit 9 Changing the Fuse 10 Troubleshooting Guide 11 TABLE OF CONTENTS ...

Страница 3: ...TT 101 and TT 101L models Model TT 202 is floor mounted TT 202 has dual blowers and speed controls as well as dual top and rear treatment ports The unit has permanently installed rubber pads along the top to provide patient under arm comfort All Thermo Theraphy Units have an elevated top edge on 3 sides to best capture and prevent the spread of errant Celstim The controls located on the control pa...

Страница 4: ... Thermo Therapy Dry Heat Therapy 4 Hospital Grade Plug Top Inlet Port with Velcro tightening sleeves Removable Rear Panel for Access to Treatment Cavity and Easy Celstim Removal Replaceable 15 AMP Fuses TT 101 ON OPTIONAL STAND CONTROL PANEL TT 101 Fresh Air Inlet and Filter Underneath Strong Rugged Housing Control Panel Tightening Sleeves Treatment Ports Complete with Removable Velcro ...

Страница 5: ... 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Thermo Therapy Dry Heat Therapy 5 TT 101L ON OPTIONAL STAND CONTROL PANEL TT 101L Treatment Ports Complete with Removable Velcro Fresh Air Inlet and Filter Underneath Strong Rugged Housing Tightening Sleeves ...

Страница 6: ... Thermo Therapy Dry Heat Therapy 6 TT 202 ON OPTIONAL STAND CONTROL PANEL TT 202 Top Treatment Ports Removable Upper Panel for Easy Celstim Removal Removable Panel for Access by Qualified Repair Personnel Top and Rear Treatment Ports with Removable Velcro Tightening Sleeves Air Intake and Filter Hospital Grade Plug Control Panel See Below Lower front storage compartment Locking Casters ...

Страница 7: ...Therapy models are shipped complete with the proper amount of sterilized Celstim and as soon as they are carefully unpacked they are ready to go If shipping damage has occurred notify Whitehall Manufacturing immediately so a proper claim can be made and replacement or repair secured SPECIFICATIONS TT 101 the outside dimensions are 19 1 2 50 cm L x 16 1 2 41 cm H x 10 1 2 27 cm When placed on the o...

Страница 8: ...y must be reviewed as with any heat modality for heat sensitivity and circulatory problems Again good ventilation should be considered and patients and operators sensitive to dust should with a mask and or the treatment ports and the extremity being treated could be covered with a damp towel Constant supervision is necessary when the unit is used with children invalids or any one who cannot safely...

Страница 9: ...er wrench to remove the filter cover The housing can be cleaned with a mild household cleaner without damage as its surface is similar to that found on kitchen counters and cabinets The treatment port sleeves can be washed and replaced To remove the sleeves carefully pull the bottom of the rims toward the center away from the side and at the same time pull or push them up and out of the housing Th...

Страница 10: ... holders at rear of the unit near cord Depress the Fuse holder caps with the use of a common blade screwdriver or fingers and rotate counterclockwise approximately 90 or until the cap becomes loose Remove the fuse holder cap exposing the glass fuse Remove the blown fuse Once the old fuse has been removed replace it with a new fuse of the same kind and amperage Re install the fuse holder cap by dep...

Страница 11: ... Unit unplugged unit fuse s has blown electric outlet supply breaker has opened local GFCI or GFI has opened or the switch is faulty Check outlets GFCI otherwise call an electrical or qualified repair personnel Heat indicating light is not lit when power on and unit is heating Burned out indicator light Refer to qualified repair personnel Blower speed cannot be controlled or will not operate at fu...

Страница 12: ... 968 6681 Fax 626 855 4862 Web www whitehallmfg com E mail info whitehallmfg com Whitehall Manufacturing is a Division of Acorn Engineering Company 6900 101 000 May 2009 Any questions regarding servicing of products in Europe or the Middle East should be directed to Niva Medical Company Olarinluoma 14 B FIN 02200 Espoo Finland Phone 358 9 615 00 540 Fax 358 9 615 00 545 Web www nivamedical fi E ma...