WIRING INSTRUCTIONS
7.
With the cabinet installed, the air cleaner can now be
wired to electrical input source.
WARNING
!
Installation of this unit must comply with local
electric codes or other applicable codes.
Review and understand local codes prior to in-
stallation.
Failure to do so could result in serious personal
injury or death.
CAUTION
!
Electrical power to the furnace should be turned
off or disconnected at the circuit breaker.
8.
The air cleaner must be wired through the furnace
controls to a 240 VAC 60 Hz electrical source. Ensure
that electrical connections to the air cleaner are
installed properly (see Figure 17).
The air cleaner should not have power unless the
furnace blower is on.
Floor
Conduit
Duct
Electronic
Air Cleaner
Figure 18
Cooling Fan
Relay
(External)
N.O.
N.O.
Brown
Fan Control
(Open)
N.O.
N.O.
N.C.
N.C.
N.C.
240 Volt
60 Hz
240 Volt
60 Hz
240 Volt
Relay (OFF)
(Customer
Supplied)
240 Volt
2 Speed
Fan
Hi
Lo
C
Electronic
Air Cleaner
Cooling Mode - Fan Operating in Hi Speed
Cooling Fan
Relay
(External)
N.O.
N.O.
Brown
Fan Control
(Closed)
N.O.
N.O.
N.C.
N.C.
N.C.
240 Volt
60 Hz
240 Volt
60 Hz
240 Volt
Relay (ON)
(Customer
Supplied)
240 Volt
2 Speed
Fan
Hi
Lo
C
Electronic
Air Cleaner
Heating Mode - Fan Operating in Low Speed
Figure 17
Vertical
Section
Tape All
Joints
Wood Block
Figure 16