HOW THE AIR CLEANER
WORKS

Dirt particles flowing through the ducts (Figure 1) first
enters the pre-filters (A) where large particles (hair, lint,
etc.) are trapped. Smaller particles (smoke, dust, pollen,
etc.) pass through these pre-filters and enter the ionizing
section (B). Here each tiny particle receives a positive
electrical charge. These charged particles then enter the
collecting section (C). This section consists of a series of
aluminum plates which are alternately charged negative
and positive.

The positive charge of the particles cause them to be
repelled by the positive plates and attracted to the nega-
tive plates where they are collected . . . just as a magnet
attracts iron filings.

Clean-filtered air re-enters the supply duct system.

CONSTRUCTION OF THE
AIR CLEANER

Not only is your air cleaner easy to install, it is also easy
to operate and maintain. Its basic components, and their
functions, are as follows: (See Figure 2)

Cabinet - mounts to existing duct work and houses the

collecting cells and pre-filters.

Collecting Cells - are made in two sections and perform

the actual collecting of dust, dirt, and other impu-
rities from the air. They contain the ionizing and
collection sections described above.

Each cell must be installed with the ionizing wires
on the air entering side. Each cell must be ori-
ented with the handles and contact button (Fig-
ure 2) toward the operator.

Pre-filters - are in two sections which are interchange-

able. They serve as a pre-filter to trap large
particles such as hair and lint before they can
enter the cell sections.

Power Pack- contains operating light as well as the

power supply that converts the 240 volt power to
the high-voltage, direct current required for the
collecting cell.

A

B

C

Dirty Air In

Clean Air Out

Figure 1

Cabinet

Pre-Filters

Handle

Contact
Button

Contact
Button

Collecting Cells

Power Pack

Figure 2

Содержание Electro-Air 10C27S-010

Страница 1: ...Service Guide Technical Repair Guide Repair Parts Part No 37 6123D Replaces 37 6123C 0032 Electronic Air Cleaner Printed In U S A UL Listed CSA Certified by White Rodgers Please read and familiarize y...

Страница 2: ...it must comply with local electric codes or other applicable codes Review and understand local codes prior to in stallation Failure to do so could result in serious personal injury or death CAUTION CA...

Страница 3: ...easy to operate and maintain Its basic components and their functions are as follows See Figure 2 Cabinet mounts to existing duct work and houses the collecting cells and pre filters Collecting Cells...

Страница 4: ...ream from the air filter If your furnace duct system has a pre installed boot discard front cover of boot and slide the air cleaner component inside the boot Applies to 14C27S 010 and 20C27S 010 If fu...

Страница 5: ...t offset to match air filter opening If duct connection to furnace allows less than nine inches for mounting the air cleaner shorten the lateral trunk or attach an offset fitting to the elbow HORIZONT...

Страница 6: ...attached directly Figure 13 or a starting collar can first be fitted to the furnace inlet A butt or slip joint can be used Securely attach the cabinet to furnace inlet using at least two of the mount...

Страница 7: ...t electrical connections to the air cleaner are installed properly see Figure 17 The air cleaner should not have power unless the furnace blower is on Floor Conduit Duct Electronic Air Cleaner Figure...

Страница 8: ...r service problems see Basic SST UST Service Guide Operating Light On Off Switch 9 Remove junction box cover and install the required bushing into the 3 4 in Knock out With the supply voltage turned o...

Страница 9: ...nd rinse thoroughly with clean water 6 Allow cell s and pre filter s to drip dry for a mini mum of 2 hours Cell s and pre filter s may be tipped at a slight angle to expedite the drip dry pro cess 7 R...

Страница 10: ...loose ionizing wire s cracked insulator s etc 3 Collecting cells dirty A Clean cells as instructed in this manual 4 Faulty power supply see power supply checkout procedure BASIC SST UST SERVICE GUIDE...

Страница 11: ...el in locating and correcting any malfunction that might occur to render the air cleaner ineffective or inop erative The air cleaner has been designed with replace able components such as the high vol...

Страница 12: ...tact 4 Using an extension cord apply 240 VAC to power pack Turn power switch to ON position 5 Connect meter negative lead to metal frame of collecting cell Use high voltage probe to measure voltage at...

Страница 13: ...13 NOTES...

Страница 14: ...14 14 REPAIR PARTS...

Страница 15: ...F844 0131 11 Switch F876 0202 F876 0202 F876 0202 F876 0202 12 Power Pack Cabinet Only N A N A N A N A 13 Connector Male F827 0017 F827 0017 F827 0017 F827 0017 14 Power Supply F858 0975 F858 0975 F8...

Страница 16: ...a White Rodgers Electronic Air Cleaner or product containing a White Rodgers Electronic Air Cleaner Although White Rodgers does not extend a warranty directly to consumers White Rodgers does extend a...

Отзывы: