background image

6

Once the specified delay time has expired the second stage 
valve will be energized.
When the second stage of the thermostat is satisfied, the inducer 
motor is reduced to low speed and the second stage gas valve 
is de-energized.
On the 50M58 control, the circulator will remain at high heat 
speed for 30 seconds following the opening of the second stage 
gas valve and then is reduced to low heat speed.
When the first stage of the thermostat is satisfied, the first stage 
gas valve is de-energized and the HEAT delay-to-fan-off begins 
timing. The inducer will postpurge for an additional 15 seconds, 
then the inducer and humidifier will turn off. Upon completion 
of the HEAT delay-to-fan-off period, the 50M58 circulator is 
turned off. The electronic air cleaner on the control is also de-
energized at this time.
If flame is not detected during the trial-for-ignition period or if the 
flame is detected/sensed and then lost before completion  of 10 
seconds of establishment, the gas valve is de-energized, the 
ignitor is turned off, and the control goes into the “retry” sequence.
The “retry” sequence provides a 60-second wait with the inducer 
interpurge following an unsuccessful ignition attempt (flame not 
detected). After this wait, the ignition attempt is restarted. Two 
retries will be attempted before the control goes into system 
lockout.
If flame is established for more than 10 seconds after ignition, 
the 50M58 controller will clear the ignition attempt (or retry) 
counter. If flame is lost after 10 seconds, the control will restart 
the ignition sequence.
A momentary loss of gas supply, flame blowout, or a shorted or 
open condition in the flame probe circuit will be sensed within 
2.0 seconds. The gas valve will de-energize and the control will 
restart the ignition sequence. Recycles will begin and the burner 
will operate normally if the gas supply returns, or the fault condi-
tion is corrected, before the last ignition attempt. Otherwise, the 
control will go into system lockout.
If the control has gone into system lockout, it may be possible 
to reset the control by a momentary power interruption of 
10 seconds or longer. Refer to SYSTEM LOCKOUT AND 
DIAGNOSTIC FEATURES.

OPTION SWITCHES

Option switches on the 50M58-289 control are used to determine 
the length of the delay-to-fan-off periods. The following tables 
show the time periods that will result from the various switch 
positions.

When using a single stage thermostat, second stage delay is 
based on the setting of switch S1-1, S1-2 shown below.

OPTION SWITCHES S1-3 & S1-4 POSITIONS

HEAT delay-

to-fan-off:

On “S1,”

set switch #:

3

Off

Off

On

On

4

Off

On

Off

On

90 sec.*

120 sec.

150 sec.

180 sec.

*Factory default setting

OPTION SWITCHES S1-1 & S1-2 POSITIONS – COOL CIRCULATOR SPEED

2nd Stage delay for single stage thermostats

Delay Time:

On "S1" set switch #

1

2

Off

Off

Off

10 min.

On

Off

Auto min.

Off

On

20 min.

On

On

*Factory default setting– two stage thermostat

OPTION SWITCH S3 POSITION – HEAT CIRCULATOR SPEED

DIP Switch S3 Setting

S3

*1   2

1   2

1   2

1   2

Position

OFF OFF

ON OFF

ON ON

OFF ON

SPEED TAP

G

T1

T1

T1

T1

W1

T1

T3

T3

T4(60Hz)

W2

T2

T2

T4(60Hz)

T4(120Hz)

*Factory default settings

OPTION SWITCH S2 POSITION

DIP SWITCH S2 SETTING

S2

*1 2

3

1 2 3 1 2

3

1 2 3 1 2 3 1 2

3

1 2 3 1 2 3

Position

OFF OFF OFF ON OFF OFF ON ON OFF OFF ON OFF OFF OFF ON OFF ON ON ON OFF ON ON ON ON

SPEED T

AP

G

T1

T1

T1

T1

T1

T1

T1

T1

W1

T1

T1

T1

T1

T1

T1

T1

T1

W2

T2

T2

T2

T2

T2

T2

T2

T2

Ylo

T4 (60hz)

T3

T3

T4 (60hz) T4 (60hz)

T3

T2

T2

Y

T4 (120hz) T4 (60hz) T4 (120hz)

T1

T2

T4 (120hz) T4 (120hz)

T3 

*Factory default setting

Average Calculated 

Duty Cycle % 

Low to High 

Stage Delay

Demand

Equals

or less than

0

38

12 minutes

Light

38

50

10 minutes

Light to Average

50

62

7 minutes

Average

62

75

5 minutes

Average to Heavy

75

88

3 minutes

Heavy Light

88

100

1 minute

Heavy

HEAT MODE

In a typical system, a call for first stage heat is initiated by closing 
the W1 thermostat contacts. The inducer blower is energized 
at high speed and the control waits for the low pressure switch 
contacts to close. The humidifier (optional) is also energized at 
this time. Once the low pressure switch contacts close, a pre-
purge is initiated. Then the inducer changes to low speed and 
the 120V ignitor is powered.
At the end of the ignitor warm-up time, the first stage of the two 
stage manifold gas valve is energized (low fire). Once flame 
is detected, the HEAT delay-to-fan-on period begins. After the 
delay-to-fan-on period ends, the 50M58 control will energize 
the circulator fan at low heat speed. The electronic air cleaner 
(optional) will also energize at this time.
For a two-stage thermostat, a call for 

second stage

 heat (W1 

and W2) after a call for first stage heat will energize the inducer 
at high speed and the circulator at high heat speed. The second 

stage pressure switch contacts will close and energize the second 
stage gas valve (high fire).
For a single-stage thermostat, when a call for heat occurs 
(W1), a 10, 20 minute or auto mode heat staging timer will be 
activated (timing is selectable with option switches S1-1 and  
S1-2 positions). Following this delay, the second stage heat is 
energized as above.
The AUTO model algorithm is a method of energizing the second 
stage gas valve based on the recent average of the heating duty 
cycle. During a typical heating day, the low to high stage delay 
is determined by using the average calculated duty cycle from 
the table below.

OPERATION 

 

 OPERATION

Содержание 50M58-289

Страница 1: ...s recommended installation service instructions to ensure proper operation 50M58 289 2 Stage X 13 Style Hot Surface Ignition Control INSTALLATION INSTRUCTIONS FAILURETO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE PRECAUTIONS CONTENTS Description 1 Precautions 1 Specifications 2 Installation 3 Mounting Wir...

Страница 2: ...period of time between energizing the main gas valve and deactivation of the ignition means prior to the end of TFI 3 Retries The additional attempts within the same thermostat cycle for ignition when the supervised main burner flame is not proven within the first trial for ignition period 2 times Valve Sequence period Valve sequence period equals 5 seconds trial for ignition period x 1 initial tr...

Страница 3: ...nnections UL approved 105o C rated 16 gauge min stranded 1 16 thick insulation wire is recommended for all line voltage connections Afterinstallationorreplacement followappliancemanufacturer s recommended installation or service instructions to insure proper operation The 50M58 has only one serviceable part an automotive type fuse which protects the low voltage transformer from damage if its outpu...

Страница 4: ...D LO IND N IGN N CIRC N LINE N XFMR N HUM N EAC N R W2 W1 Y R W2 W1 Y2 CONDENSING UNITS 50M58 289 in other furnace THERMOSTAT FLAME SENSOR PROBE 2ND STAGE PRESSURE SWITCH N O HIGH LIMIT N C AUX HIGH LIMIT N C 1ST STAGE PRESSURE SWITCH N O GAS VALVE HLO HLI FP PS1 MVL MVH GND GND PS2 MV COM TR TH Low Voltage 24 VAC Line Voltage 120 VAC G G ROLLOUT SWITCH N C LEGEND N C Normally closed switch N O No...

Страница 5: ...alve FIRST STAGE W2 two stage thermostat W2 terminal or equivalent IGN 1 ignitor HOT side IGN N 5 ignitor NEUTRAL side circulator blower terminal TAP 1 L1 1 4 spade terminal input voltage 120 VAC HOT SIDE T1 XFMR 1 4 spade terminal 24 VAC transformer line voltage HOT SIDE EAC H 1 4 spade terminal air cleaner HOT side HUM 1 4 spade terminal humidifier HOT side CIRC N 1 4 spade terminal circulator b...

Страница 6: ...On 4 Off On Off On 90 sec 120 sec 150 sec 180 sec Factory default setting OPTION SWITCHES S1 1 S1 2 POSITIONS COOL CIRCULATOR SPEED 2nd Stage delay for single stage thermostats Delay Time On S1 set switch 1 2 Off Off Off 10 min On Off Auto min Off On 20 min On On Factory default setting two stage thermostat OPTION SWITCH S3 POSITION HEAT CIRCULATOR SPEED DIP Switch S3 Setting S3 1 2 1 2 1 2 1 2 Po...

Страница 7: ...emory the LED will flash two green flashes The control will flash the most re cent error first and the oldest error last last in first out There shall be 2 seconds between codes Solid LED error codes will not be displayed FAULT CODE RESET To clear the fault code memory push and hold the LAST ER ROR button for more than 5 seconds and less than 10 seconds Control will indicate this period by RAPID G...

Страница 8: ...wer failure restricted air flow through appliance or duct work Verify continuity through limit switch circuit and correct overheating cause 12 Module Ignitor contact failure Fault code indicates the module ignitor contacts are not functioning properly Replace module Solid Module internal fault condition Module contacts for gas valve not operating or processor fault Reset control if condition persi...

Отзывы: