Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the
National Electrical Code ANSI/NFPA No. 70
, if an external
electrical source is utilized.
This appliance is equipped with a
three-prong [grounding] plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected
to the receptacle mounting screw. With this wire completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION:
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Oiling Blower Motor
The blower motor does not have oiling holes. Do not attempt to
oil the blower motor.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To turn off gas to the unvented heater: Push
in gas control knob slightly and turn clockwise to “OFF.”
Do not force.
VFS-BK PARTS LIST
Index
No.
Part
Number
Description
1
11508
FAN CONTROL BRACKET
2
R-2503
FAN CONTROL
3
11301
BLOWER DIVERTER
4
R-2099
CORD SET
5
R-1410
STRAIN RELIEF BUSHING
6
M-147
GASKET
7
R-2804A BLOWER ASSEMBLY
8
R-5804
WIRE HARNESS
9
R-1404
SNAP BUSHING
10
11507
BLOWER SHIELD - SIDE
11
11506
BLOWER SIDE -FRONT
12
R-2805
AUTO/OFF/ON SWITCH