When used without adequate combustion and ventilation air, 

heater  may  give  off  CARBON  MONOXIDE,  an  odorless, 

poisonous gas. 

Do not install heater until all necessary provisions are 

made for combustion and ventilation air. Consult the writ-

ten instructions provided with the heater for information 

concerning combustion and ventilation air. In the absence 

of instructions, refer to the National Fuel Gas Code, ANSI 

Z223.1, Section 5.3 or applicable local codes. 

This  heater  is  equipped  with  a  PILOT  LIGHT  SAFETY 

SYSTEM designed to turn off the heater if not enough fresh 

air is available.

DO  NOT  TAMPER  WITH  PILOT  LIGHT  SAFETY 

SYSTEM!

If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and 

control compartment clean. 

CARBON MONOXIDE POISONING MAY LEAD TO 

DEATH.

Early signs of carbon monoxide poisoning resemble the flu, 

with headache, dizziness and/or nausea. If you have these signs, 

heater may not be working properly. Get fresh air at once! 

Have heater serviced. 
Some people — pregnant women, persons with heart or lung 

disease, anemia, those under the influence of alcohol , those at 

high altitudes — are more affected by carbon monoxide than 

others.
The pilot light safety system senses the depletion of oxygen at its 

location. If this heater is installed in a structure having a high 

vertical dimension, the possibility exists that the oxygen supply 

at the higher levels will be less than that at the heater. In this type 

of application, a fan to circulate the structure air will minimize 

this effect. The use of this fan will also improve the comfort level 

in the structure. When a fan is used to circulate air, it should be 

located so that the air flow is not directed at the burner.

WARNING

•  An  unvented  room  heater  having  an  input    rating  of 

more than 6,000 Btu per hour shall not be installed in a 

bathroom.

•  An  unvented  room  heater  having  an  input  rating  of 

more than 10,000 Btu per hour shall not be installed in 

a bedroom or bathroom.

•  Due to high temperatures, the appliance should be located 

out of traffic and away from furniture and draperies.

•  Children and adults should be alerted to the hazard of 

high surface temperature and should stay away to avoid 

burns or clothing ignition.

•  Young children should be carefully supervised when they 

are in the same room with the appliance.

•  Do not place clothing or other flammable material on or 

near the appliance. 

•  Installation and repair should be done by a QUALIFIED 

SERVICE PERSON. This appliance should be inspected 

before use and at least annually by a professional service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, etc. It 

is imperative that control compartments, burners and 

circulating  air  passageways  of  the  appliance  be  kept 

clean.

•  DO NOT use this fireplace if any part has been under 

water.  Immediately  call  a  qualified  service  technician 

to inspect the fireplace and to replace any part of the 

control system and any gas control which has been under 

water.

•  You must operate fireplace with fireplace screen closed in 

place. Do not close glass doors while operating heater.

•  Do not place trash, logs or other articles on the log set 

during operation.

•  During manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain 

oils, films or bonding agents. These bonding agents are 

not  harmful  but  may  produce  annoying  smoke  and 

smells as they are burned off during initial operation of 

the appliance. This is a normal temporary occurrence. 

A window should be opened during the initial bake out 

period. 

•  Correct  installation  of  the  ceramic  fiber  logs,  proper 

location of the fireplace and annual cleaning are necessary 

to avoid potential problems with sooting. Sooting, resulting 

from improper installation or operation, can settle on 

surfaces outside the fireplace. See instructions for proper 

installation.

•  WARNING:  Do  not  allow  fans  to  blow  directly  into 

the fireplace. Avoid any drafts that alter burner flame 

patterns.

•  WARNING: Do not use a blower insert, heat exchanger 

insert or other accessory not approved for use with this 

heater.

•  WARNING! This fireplace needs fresh air for ventilation 

to operate properly. This fireplace has an ODS (oxygen 

depletion  sensor)  which  will  shut  off  the  fireplace  if 

adequate fresh air is not available. 

•  Keep  appliance  area  clear  and  free  from  combustible 

materials,  gasoline  and  other  flammable  vapors  and 

liquids.

THIS IS A HEATING APPLIANCE

IMPORTANT SAFETY INFORMATION

Содержание VF24FP2-2

Страница 1: ...er to page 6 WARNING If not installed operated and main tained in accordance with the manufacturer s in structions this product could expose you to sub stances in fuel or from fuel combustion which can cause death or serious illness Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any a...

Страница 2: ...n 11 Placement of Glowing Embers Rock Wool 12 Operation Instructions Flame Appearance 12 VF24FP3 1 Lighting Instructions 13 VF24FP2 2 Lighting Instructions 14 Pilot Flame Characteristics 15 16 Main Burner and Thermostat Operation 16 VF24FP2 2 Conversion to 10 000 BTU s for Bedroom Installation 16 Wiring 17 Troubleshooting 18 Parts List 19 How to Order Repair Parts 19 Parts View 20 Optional Brick L...

Страница 3: ... of high surface temperature and should stay away to avoid burns or clothing ignition Young childrenshould becarefullysupervisedwhen they are in the same room with the appliance Do not place clothing or other flammable material on or near the appliance Installation and repairshould be done by a QUALIFIED SERVICE PERSON This appliance should be inspected before use and at least annually by a profess...

Страница 4: ...perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of newcylindersandtanks ispossible Therefore peopleshould be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tan...

Страница 5: ...r your gas company before changing spud orifice size WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installermusthaveownerfilloutandmailwarrantycardsupplied with unvented room heater 3 Installer should show owner how to start and opera...

Страница 6: ...tinuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable windows and doors and c Caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at othe...

Страница 7: ...amount of BTU Hr used BTU Hr maximum the space can support BTU Hr actual amount of BTU Hr used Example 25 600 BTU Hr maximum the space can support 38 000 BTU Hr actual amount of BTU Hr used Warning If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by...

Страница 8: ...uge connection must be placed immediately upstream of the gas supply connection to the appliance 2 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa 3 The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff ...

Страница 9: ...place opening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the fireplace opening to the ceiling should not be less than 30 inches Mantel Clearances for Built in Installation Figure 5 Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 6 No greeting cards stockings or ornamentation of any type should bepla...

Страница 10: ...g flange will secure the fireplace 6 Placeleftmantelsideagainstbase Insertdowelsinbreastboard into left mantel side 7 Use four 4 pre drilled screw holes on back of breastboard to secure breastboard to mantel sides with four 4 Phillips wood screws 8 Place mantel top onto mantel 9 Installation of fireplace into mantel is completed Installation of Trim 1 Lower bottom louver 2 Remove screen from fireplace...

Страница 11: ...ng the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert fireplace into enclosure 4 Attach nailing flanges to framing with a screw or nail 5 Finishedwallsurfacewillbeflushtotheleadingedgeoffireplace top and sides 6 Installation of built in fireplace is completed Installation of Trim 1 Lower bottom louver 2 Remove screen from fireplace 3 Remove top louver from fireplace...

Страница 12: ...cked as the log set is installed In normal operation at full rate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOTE all flames will be random by design flame height will go up and down Glowing embers rock wool can cover the pan burner in between the front and middle logs but very little is necessary to cover this area Excess ember material causes the yellow flame to becom...

Страница 13: ...le Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If applicable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure the manual shutoff valve is fully open 3 This gas log set is equipped with an ignition device piezo which lights the pilot If piezo ignitor does not light the pilot refer to Step 7 4 Turn gas control kn...

Страница 14: ... setting 3 Turn off all electric power to the appliance if applicable 4 Pushingascontrolknobslightlyandturnclockwise to OFF Do not force 5 Wait ten 10 minutes to clear out any gas Then smell for gas including near floor If you smell gas STOP Follow B in the safety information on other side If you do not smell gas Go to the Next step 6 Find pilot the pilot is located in front of rear log 7 Turn manu...

Страница 15: ...ing the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down Correct Flame Pattern Correct Flame Pattern THERMOCOUPLE LPG THERMOCOUPLE NATURAL THERMOPILE PILOT PILOT THERMOCOUPLE NATURAL THERMOCOUPLE LPG VF24FP3 1 Pilot Figure 13 VF24FP2 2 Pilot Figure 15 Incorrect Flame Pattern Incorrect Flame Pattern THERMOCOUPLE LPG THERMOCOUPLE NATURAL THE...

Страница 16: ...lint from carpeting bedding materials etc Logs Be careful cleaning and handling logs so as not to damage them If logs break or fall apart in handling spray the broken pieces and fibers with water sweep up and discard main burner orifice marked 1 30mm 9 ForPropane LP gas only remove 20 000 BTU main burner orifice marked 55 from orifice fitting and replace with 10 000 BTU main burner orifice marked 64 10 ...

Страница 17: ... be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the remote receiver adjacent to the gas valve Attention The remote receiver bracket is not used in this installation 1 The remote receiver can not be placed behind the gas valve and burner assembly 2 When facing the appliance the remote receiver must be placed to the right of the gas valve and burne...

Страница 18: ...rect Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough After ODS pilot lights keep control knob pressed in 30 seconds c Manual Shutoff valve not fully open Fully open manual shutoff valve d Thermocouple connection loose at control valve Hand tighten unti...

Страница 19: ...T SHOWN P 263 NIPPLE 8 NOT SHOWN 15465 TUBING VALVE TO PILOT REGULATOR NAT NOT SHOWN 15466 TUBING PILOT REGULATOR TO PILOT NAT NOT SHOWN R 7063 PILOT REGULATOR NAT VF24FP2 2 ONLY 19 R 5170 PILOT ASSEMBLY LPG 19 R 5171 PILOT ASSEMBLY NAT 21 P 265 ORIFICE NAT 20 000 BTU 21 P 266 ORIFICE NAT 10 000 BTU 21 P 193 ORIFICE LPG 10 000 BTU 25 24157 VALVE NAT 25 24158 VALVE LPG 26 R 2480 INLET REGULATOR LPG...

Страница 20: ...24161 0 1207 Page 20 PARTS VIEW VF24FP2 THERMOSTATIC VALVE VF24FP3 MILLIVOLT VALVE ...

Страница 21: ...inserting the 2 side brick liners 4 Loosen top and bottom 10 x 1 2 screws from each side of firebox 5 Place the 2 liner mounting brackets over the front edges of the 2 side brick liners Attach liner mounting brackets to outer casing with 4 four 10 x 1 2 screws from Step 4 6 Replacelogsintoburnerassembly Referto LogPlacement Page 12 7 Attach screen assembly to fireplace 8 Installation of optional bri...

Страница 22: ...to motor Align and attach blower assembly to outer casing side See Figure 2 10 Snap Heyco into blower shield side 11 Placeblowershieldsideadjacenttomotor Routeblowermotor wires through Heyco on blower shield side See Figure 3 and Figure 4 VFS BK for Unvented Gas Fireplace Model VF24FP2 2 VF24FP3 1 12 Attach black wire from wire harness to OFF terminal on AUTO OFF ON switch 13 Attach white black wi...

Страница 23: ...ed on left front of valve cover on burner assembly Insert blower shield front adjacent to blower motor and blower shield side Align clearance hole on blower shield front with left front screw hole on valve cover Attach blower shield front to valve cover with 10 x 1 2 screw See Figure 3 for not installed or Figure 4 for installed 25 For fireplace that is not installed replace burner assembly into in...

Страница 24: ... screws at interior top of inner casing that were loosened in Step 6 30 Attach burner assembly to inner bottom with three 3 10 x 1 2 screws from Step 5 31 Attach rear log support to inner casing with three 3 10 x 1 2 screws from Step 4 32 Place and align blower diverter on top of inner casing Attach deflector to top of inner casing with two 2 10 x 1 2 screws See Figure 6 33 Attach top louver with t...

Страница 25: ...g the ground the appliance cord plug can be plugged into the adapter and be electrically grounded CAUTION Labelallwirespriortodisconnectionwhenservic ing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Oiling Blower Motor The blower motor does not have oiling holes Do not attempt to oil the blower motor WARNING Unplugging of blower accessor...

Страница 26: ...rt number and description coincide 1 2 3 Index Number Part Number Description VPF24BR 1 Brass Trim Kit 1 11328 Trim Top 2 11326 Trim Left 3 11327 Trim Right VPF24SS 1 Stainless Steel Trim Kit 1 20227 Trim Top 2 20228 Trim Left 3 20229 Trim Right VPF24HP 1 Hammered Pewter Trim Kit 1 20224 Trim Top 2 20225 Trim Left 3 20226 Trim Right ...

Страница 27: ...24161 0 1207 Page 27 SERVICE NOTES ...

Страница 28: ...24161 0 1207 Page 28 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ...

Отзывы: