background image

23015-9-1108

Page 25

INSERT pARTS LIST

 USE ONLY MANUFACTURER’S REpLACEMENT pARTS. USE OF ANY OTHER pARTS COULD CAUSE INJURY OR DEATH.

 

pART NUMBER

  INDEX NO.  Dv25IN33L(N,p) 

Dv33IN33L(N,p)  Dv35IN33L(N,p) 

DESCRIpTION

 

22950 

22950 

22950 

GUIDE, FLUE CONNECTOR

 

23309 

23211 

23211 

VENT SLIDE PLATE ASSEMBLY

 

R9188 

R9188 

R9188 

GASKET, TOP

 

R9192 

R9196 

R9199 

BRICK PANEL, BACK

 

R9195 

R9198 

R9201 

BRICK PANEL, RIGHT

 

R9194 

R9197 

R9200 

BRICK PANEL, LEFT

 

20448 

20448 

20448 

BRICK LINER BRACKET

 

22951 

22972 

22972 

FIREBOX BAFFLE

 

22958 

22976 

22990 

LOG SHELF

 

10 

23303 

23006 

23320 

GLASS DOOR & FRAME ASSEMBLY

 

11 

23329 

17169 

17127 

LOUVER ASSEMBLY 

 

12 

23158 

23160 

23160 

LOG SUPPORT, FRONT

 

13 

23315 

23024 

23024 

GRATE TANG / BRACKET ASSEMBLY

 

14 

R3435 

R3435 

R3435 

WIRE ASSEMBLY

 

15 

R3436 

R3436 

R3436 

SWITCH, REMOTE/OFF/ON

 

16 

R2708 

R2708 

R2708 

IGNITER, PIEZO

 

17 

23159 

23161 

23504 

LOG SUPPORT, REAR

 

18 

23521 

23521 

23521 

FLAME SHIELD, RIGHT

 

19a 

R7612 

R7612 

R7612 

PILOT ASSEMBLY, SIT (NAT)

 

19b 

R7611 

R7611 

R7611 

PILOT ASSEMBLY, SIT (LP)

 

20 

R9189 

R9189 

R9189 

GASKET, PILOT

 

21 

R5676 

R5676 

R5676 

AIR SHUTTER

 

22 

P253 

P253 

P253 

FITTING, ORIFICE ANGLED 

 

23a 

P286 

P270 

P244 

ORIFICE, MAIN BURNER (NAT)

 

23b 

P214 

P250 

P210 

ORIFICE, MAIN BURNER (LP)

 

24 

23311 

23017 

23017 

BURNER ASSEMBLY

 

25 

22959 

22959 

22959 

VALVE BRACKET

 

26 

22739 

22738 

22738 

TUBING ASSEMBLY

 

27 

22973 

22973 

22973 

SHIELD, VALVE

 

28a 

R7577 

R7577 

R7577 

VALVE, SIT GAS (NAT)

 

28b 

R7578 

R7578 

R7578 

VALVE, SIT GAS (LP)

 

29 

22953 

22953 

22953 

PIEZO BRACKET

 

30 

16223 

16223 

16223 

SPRING RETAINER ASSEMBLY

 

31 

N/A 

23690 

23690 

FLAME SHIELD, LEFT

 

32 

M163 

M163 

M163 

GASKET, FLUE CONNECTOR

 

33 

23009 

23009 

23009 

FLUE CONNECTOR ASSEMBLY

 

34 

R9257 

R9219 

R9219 

LOG, RIGHT FRONT

 

35 

R9258 

R9220 

R9220 

LOG, RIGHT CENTER

 

36 

R9260 

R9252 

R9252 

TWIG, RIGHT

 

37 

R9261 

R9253 

R9253 

TWIG, LEFT

 

38 

R9255 

R9217 

R9217 

LOG, BACK

 

39 

R9259 

R9251 

R9251 

LOG, LEFT CENTER

 

40 

R9256 

R9218 

R9218 

LOG, LEFT FRONT

 

41 

R9268 

R9268 

R9268 

WIRE ASSEMBLY - SWITCH

 

42 

R2522 

R2522 

R2522 

SWITCH, ON / OFF

 

43 

18879 

18879 

18879 

RHEOSTAT ASSEMBLY (SPEED CONTROL)

 

44 

R7649 

R7649 

R7649 

CONTROL, FAN

 

45 

24925 

24925 

24925 

BLOWER SUB-ASSEMBLY (W/MOUNTING PLATE, PAD)

 

46 

R2204 

R2204 

R2204 

CORD SET

 

47 

R7591 

R7591 

R7591 

FLEXLINE W/SHUTOFF VALVE

Содержание Dv25IN33L-1

Страница 1: ...ce is not convertible for use with other gases unless a certified kit is used GAS FIRED Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do...

Страница 2: ... 10 12 Vertical Termination 13 Alternate ON OFF Switch Installation 14 Surround Panel Installation 15 Blower Accessory Information 16 Log Placement 17 Operating Instructions 18 Standing Pilot Lighting Instructions 19 Standing Pilot Wiring 20 Standing Pilot Troubleshooting 21 Insert Maintenance and Service 22 Decorative Accessories 23 Insert Parts View 24 Insert Parts List 25 How to Order Repair Pa...

Страница 3: ...t clean Vent cap is hot while fireplace is in operation Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control compartments burners and circulating air passagewa...

Страница 4: ... perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled o...

Страница 5: ...having jurisdiction State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from the American National Standards Institute...

Страница 6: ...ing to an existing round fireplace chimney pipe DVVK3FV Vertical Vent Kit 25 Two pieces of 25 FlexVent Rectangle Cap Flashing connectors and clamps Recommended when installing to a square or rectangular clay flue DVK35 Vent Extension Kit 35 flex vent extension section with 2 connectors and 4 clamps Note When installing vent caps special locally made flashings may be required to properly seal the v...

Страница 7: ...4 28 14 1 2 11 1 8 25 1 4 12 3 4 17 18 5 16 27 6 3 4 9 20 25 5 8 40 DV33IN 22 3 4 31 16 14 1 8 28 1 4 14 1 4 18 3 4 21 5 16 30 8 1 4 10 1 2 21 1 2 28 5 8 43 DV35IN 24 3 4 34 16 16 1 8 31 1 4 14 1 4 21 3 4 23 5 16 33 8 1 4 10 1 2 23 30 5 8 46 A D C B Figure 2 Fireplace Opening Dimensional Information Sizing MINIMUM FIREPLACE OPENING DIMENSIONS MODEL NO HEIGHT A FRONT WIDTH B DEPTH C REAR WIDTH D DV...

Страница 8: ...0 1 3 4 23 11 Combustible Material No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplace The flow of heat can ignite combustibles Figure 4 8 MINIMUM CLEARANCE TO PERPENDICULAR COMBUSTIBLE SIDE WALL FROM EDGE OF DOOR FRAME Figure 3 ...

Страница 9: ...ures results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the fireplace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have a built in pressure regulator in the gas valve Natural gas models will have a manifold pressure of approximately 3 5 w c 871kPa at the valve outlet with the inlet pressure to the valve from a minimum o...

Страница 10: ...isting air circulation vents or grills NOTE Cutting of sheet metal parts of a fireplace in order to install the fireplace insert is prohibited WARNING Only the surround as supplied may be used to cover integral grills on the solid fuel burning fireplace No other components such as shrouds sheet metal plates etc may be used to seal off vents 7 To assure top performance safety and efficiency inserts...

Страница 11: ...himney may need to be removed to allow installation of the flexible vent pipe When installing into a zero clearance factory built wood burning fireplaces the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily Connecting the Vent Pipe Caution Sharp edges Always use gloves when installing Install the 3 inch flexi...

Страница 12: ...ENT CONNECTION RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED USE HIGH TEMP SEALANT ON VENT CONNECTIONS USE HIGH TEMP SEALANT ON VENT CONNECTIONS ROUND TERMINATION CAP DVKI KIT ROUND CO LINEAR TO CO AXIAL ADAPTOR BLOWER ACCESS COVER PLATE BLOWER POWER CORD OPTIONAL LOW VOLTA...

Страница 13: ...ently dripping out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold weather 4 Inspectjointstoverifythatnopipesectionsorfittingshavebeen disturbed and consequently loosened Also check mechanical supports such as wall straps or plumbers tape for rigidity Determining ...

Страница 14: ...d panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides Lift the surround panel assembly slightly until the bottom return flange top panel is positioned over the top flange on the insert This secures the sur round panel assembly to the insert without screws Traditional Cast Iron Surrounds 1 Find the coiled low voltage wire assembly an...

Страница 15: ...N FINISHING THE FIREPLACE INSERT NEVER OBSTRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER NOTE INSTALL SURROUND PANELS SO THAT THE TOP PANEL RETURN FLANGE SLIDE S OVER THE TOP FLANGE ON THE INSERT 1 Ref SURROUND PANEL ASSEMBLY ENGAGE SIDE PANEL HOOKS WITH THE NOTCHES PROVIDED ON THE SIDE FLANGES Figure 14 Figure 15 ...

Страница 16: ...and BTU input level setting control by adjustment of the HI LO knob located on the gas valve Blower removal instructions Servicing or removal of the blower system must be performed by a qualified service person If the blower assembly Item 45 page 24 must be replaced the following steps are recommended for removal 1 Turn off gas and disconnect the electrical supply 2 Remove the glass door assembly ...

Страница 17: ... support Note DV25IN models incorporate two small tabs in the rear log support that keep the back log positioned correctly DV33IN models have one small tab in the rear log support to ensure the back log is in the correct position The DV35IN models will have two tabs bent forward in the rear log support to ensure proper left to right positioning of the log plus one small tab near the center that ke...

Страница 18: ...N position This time period allows the millivolts electrical current to build up to a sufficient level allowing the gas control to operate properly 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in control compartment behind the door assembly CAUTION Duringtheinitialpurgingandsubsequentlightings never allow the gas valve control k...

Страница 19: ...ch to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell ne...

Страница 20: ...ptional Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8m or less length of 18 A W G minimum wire and connect it to the fireplace valve pigtails WARNING DO NOT CONNECT THE 110 120 VAC TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC TION WHEN SERVICING CONTROL WIRING ERRORS CAN CAUSE IMPROPER AND...

Страница 21: ...ctions from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading atTH TP TPterminals of the gas valve The meter shouldread350millivoltsminimum whileholdingthevalve knob depressed in the pilot position with the pilot lit and the REMOTE OFF ON switch in the OFF position Replace the...

Страница 22: ...sure that no debris is interfering with the flow of air Inspect entire vent system for proper function Cleaning Logs Use a soft brush attachment on a vacuum cleaner to gently remove dust or soot deposits from logs and burner Cleaning Glass Door Frequency After the first 3 to 4 hours of use As necessary after initial cleaning By Home owner Task Remove and clean glass after the first 3 to 4 hours of...

Страница 23: ...at your dealer can furnish contact Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewter Brushed Stainless Black Black Black Standard Gold Finish Hammered Pewter Brushed Stainless Black Used to finish off bottom of insert and surround p...

Страница 24: ...23015 9 1108 Page 24 INSERT PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 39 40 41 7 12 32 42 43 18 44 45 47 46 ...

Страница 25: ...T ASSEMBLY SIT LP 20 R9189 R9189 R9189 GASKET PILOT 21 R5676 R5676 R5676 AIR SHUTTER 22 P253 P253 P253 FITTING ORIFICE ANGLED 23a P286 P270 P244 ORIFICE MAIN BURNER NAT 23b P214 P250 P210 ORIFICE MAIN BURNER LP 24 23311 23017 23017 BURNER ASSEMBLY 25 22959 22959 22959 VALVE BRACKET 26 22739 22738 22738 TUBING ASSEMBLY 27 22973 22973 22973 SHIELD VALVE 28a R7577 R7577 R7577 VALVE SIT GAS NAT 28b R7...

Страница 26: ...ine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fireplace Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments c...

Страница 27: ...23015 9 1108 Page 27 SERVICE NOTES ...

Страница 28: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...