3
TECHNICAL DATA
GENERAL
Front loading resistance sensing tumble dryer with gas
heating. Reverse action drum tumble. Electronic control.
2-temperature exhaust thermostat control. Induced air flow
enters dryer through front grille, some passes through the
gas burner into the rear ducting and some into the cooling
passages, this mixed air enters the drum through the rear
perforations, passes through the clothes, lint filter, and the
fan and is discharged through the vent at the rear.
CONNECTIONS
Gas pressure: Rp
1
/
2
(
1
/
2
” B.S.P. parallel internal thread).
Nominally 20mbar
Electric:
230V. 50 Hz, earthed supply, 13A fuse.
(wall socket must have efficient earth
connection and correct polarity)
DIMENSIONS
Height 85 cms. (33
1/
2
”)
Width 59.6 cms. (23
1/
4
”)
Depth 57 cms. (22
1/
2
”)
Depth when rear vent hose assembled 60cms. (23
5/
8
”)
WEIGHT
With packing
37 kg
Without packing 36 kg
SUPPORT
Machine rests on 2 rear positioned rollers and 2 non
adjustable feet.
AIR-FLOW
Approximately 120 cubic metres per hour with capacity
clothes load.
IDENTITY
Manufacture date, and serial number are displayed on a
plate revealed when machine door is open.
The first 4 numerals identify year and week of manufacture.
The last 6 numerals identify the machine. ALL
INFORMATION FROM THIS PLATE SHOULD BE
QUOTED IN ANY SERVICE COMMUNICATION.
COMPONENTS
DRIVE MOTOR
Permanent split capacitor (8µF) 4 pole—Approx.
1
/
8
HP
Overload protection approx. 130°C
BURNER
Pressed steel with slotted flame perforations.
Heat input: 3.0kW (10235 Btu/hr). Injector 1.32 mm dia.
GAS CONTROL
Type: Pactrol full sequence flame control, P16A GTD(CE)
414601. Ignition electrode gap to burner 3 to 4mm Flame
failure electrode (4213 078 52641). Height from heater
base to centre of electrode 27.0±0.5mm.
INLET THERMOSTAT
(Brown wires identify)
Bi-metal contacts normally closed.
Contacts open if airflow restricted.
Contacts open 130˚C ± 3˚C
Contacts reset 100˚C ± 5˚C
INLET TEMPERATURE LIMITER
(White wires identify)
Bi-metal contacts normally closed.
Contacts open if INLET THERMOSTAT fails.
Contacts open 143˚C ± 4˚C
Contacts reset 95˚C ± 10˚C
EXHAUST THERMOSTATS
Bi-metal contacts normally closed.
Normal Fabrics:
Contacts open 60˚C ± 3˚C
60˚C (green spot
Contacts reset 49˚C ± 4˚C
identification)
Delicate Fabrics:
Contacts open 50˚C ± 3˚C
50˚C (red spot
Contacts reset 39˚C ± 4˚C
identification)
DRUM
Volume
105 litres
Speed
approx. 50/59 r.p.m.
Capacity
7 kg dry cotton
Rotation
clockwise 6 mins., anticlockwise 10 secs
TRANSMISSION
Poly-vee belt driven by vee-grooved motor pulley to outer
circumference of drum.
ELECTRONIC CONTROL
8 selectable programmes giving choice of dryness level
and timed programmes. When drying is complete,
intermittent tumbling (anticrease) follows until the
machine is unloaded.
HEATER SWITCH
Single pole, ON/OFF, PUSH-PUSH
START SWITCH-momentary push switch.
R.F.I. FILTER
0.1µF + 2x 2x5mH + 2M2
ACCESSORIES
VENT HOSE ASSEMBLY
0312 001 01001
WALL/WINDOW VENT KIT
0312 005 01001
STACKING KIT
0312 003 01001
RESTRAINING KIT
0312 006 01001
Содержание ECO 83A
Страница 12: ...12 Chart 3 Motor runs Full Sequence Control produces ignition sparks but gas does not ignite ...
Страница 14: ...14 ...
Страница 15: ...15 WHITE KNIGHT ECO 83A_ CROSSLEE P L C EXPLODED VIEW 1 367 ...
Страница 17: ...17 WHITE KNIGHT ECO 83A_ CROSSLEE P L C EXPLODED VIEW 3 INTERNALS VIEWED FROM REAR ...
Страница 18: ...WHITE KNIGHT ECO 83A_ CROSSLEE P L C EXPLODED VIEW 4 INTERNALS VIEWED FROM REAR 18 ...
Страница 19: ...19 WHITE KNIGHT ECO 83A_ CROSSLEE P L C EXPLODED VIEW 5 HEATER ASSEMBLY ...
Страница 23: ...23 ...
Страница 24: ...Manufactured By Crosslee plc Halifax Road Hipperholme Halifax HX3 8DE 4213 094 79382 ...