background image

1INSTALLATION

The dryer is designed for installation using a flexible gas
connection with tubing in accordance with B.S.669.
Ensure that the supply gas sizing is adequate.
When installing, position the appliance so that the plug is
accessible.
An electric supply cord with moulded-on 13 Amp.plug is
fitted at the back of the dryer.The length is 1.5 m.(5ft.).
If there are any other appliances that are relatively high
rated (eg a central heating boiler)fed from the same gas
supply branch.It is advisable to perform the verification of
inlet pressure with both appliances in operation.
Prior to installation, check that the local distribution
conditions, nature of gas and pressure and adjustment of
the dryer are compatible.

2 AIR SUPPLY

The tumble dryer shall be installed in a room or internal
space having an openable window, or equivalent.The
customer must be advised that this must be kept open
during use.

Purpose provided ventilation of 100cm shall also be 
provided where the room volume is less than 3.7m³/kw of 
appliance rated heat input.
Additional guidance on the provision of air supply may be
obtained from BS5440 parts 1 and 2 and BS 7624:2004
If the dryer is to be installed in a room or internal space 
that
already contains one or more fuel burning appliances, the
ventilation requirements above, together with any
additional requirements of BS5440-2:2000, 5,5 shall be
applied.

3 POSITION

The dryer must not be installed in a bedroom, bathroom 
or shower room.
Great care is required in the location of the dryer in
premises where concentrations of flammable vapours 
may accumulate, e.g.commercial garages and associated
workshops.
The dryer can be placed against a wall, other appliances,
kitchen furniture and similar surfaces.

4 VENTING 

The dryer must be fitted with an exhaust vent hose and 
the
end either hung out of a window or fitted to a wall/ 
window vent connection.

Note: 

Do not obstruct or add a mesh to the vent hose

outlet during use and ensure that it cannot be blocked or 
bent sharply which obstruct the air flow.
It is recommended that the interior of the hose be
periodically inspected and cleaned if necessary.

PERMANENT VENTING

Accessory wall/window vent kit CL005 is available:
See illustration for necessary hole through wall.Dim A=
200mm and Dim B= 100mm for direct alignment.
Note DimBmay be increased to 200mm to facilitate easier
drilling if required.

5 POSITION OF DRYER AND CONNECTIONS

The illustration shows the minimum space required by the
dryer and the position of the gas wall connector.It is not
acceptable to use a forward facing mounting plate because
of the space limitation.The sideways facing assembly must
be used and this should be fitted so that the flexible hose
hangs down from the bayonet connector.

A 13 Amp socket must be provided within a distance of 1.4
m (55 in.) of the cable entry into the dryer.The socket must
have an efficient earth connection.

If the dryer is to stand on a surface above the floor or on
top of a washing machine (using the Stacking Kit) then the
750 mm dimension is measured above the supporting
surface.

If the dryer is installed under a worktop there must be a
minimum gap of 15 mm between the top of the dryer and
the underside of the worktop to allow for ventilation.

If it is intended to move the dryer regularly for use then the
Restraining Kit must be fitted to prevent possible damage
to the gas connection.

We also recommend the fitting of a restraining kit to any
dryer which is stacked.

If using accessories:

Wall/Window Vent Kit 

Stacking Kit 

Restraining Kit 

See separate fitting instructions included with each Kit.

INSTALLATION  

4

Содержание ECO 43A

Страница 1: ...stallation and Use Regulations 1998 Guidance may be obtained from the relevant parts of B S 7624 B S 5440 parts 1 and 2 B S 6891 current editions I E E Wiring Regulations and relevant Building Regulations Failure to install the appliance correctly could invalidate the warranty liability claims and could lead to prosecution FOR USE IN THE UNITED KINGDOM AND IRELAND WITH NATURAL GAS ONLY I2H GAS SUP...

Страница 2: ...CTIVE LVD 2006 95 EC EN60 335 1 EN60 335 2 11 GAS APPLIANCE DIRECTIVE GAS 90 396 EEC BS 5258 PART 17 1992 EN 1458 1 2000 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2004 108 EC EN55014 EN 61000 3 2 EN 61000 3 3 EN 50366 2 WARNING THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH THE LOCAL REGULATIONS IN FORCE AND ONLY IN A WELL VENTILATED SPACE READ THE INSTRUCTIONS BEFORE USING OR INSTALLING THIS ...

Страница 3: ...r 8µF 4 pole Approx 1 8 HP Overload protection approx 130 C BURNER Pressed steel with slotted flame perforations Heat input 3 0kW 10235 Btu hr Injector 1 32 mm dia 3 CONTROL Type Pactrol full sequence flame control P16AGTD CE 414601 Ignition electrode gap to burner 3 to 4mm Flame failure electrode 4213 078 52641 Height from heater base to centre of electrode 27 0 0 5mm INLET THERMOSTAT Brown wires...

Страница 4: ...urniture and similar surfaces 4 VENTING The dryer must be fitted with an exhaust vent hose and the end either hung out of a window or fitted to a wall window vent connection Note Do not obstruct or add a mesh to the vent hose outlet during use and ensure that it cannot be blocked or bent sharply which obstruct the air flow It is recommended that the interior of the hose be periodically inspected a...

Страница 5: ...arried out it should be carried out by a competent person i e registered Engineer 9 STACKING Instructions for stacking if required are supplied with the stacking kit PROGRAMME Clockwise rotation of the control knob closes switch contacts within the timer to a energise the drive motor and b energise the full sequence flame controller The timer switch controlling the drive motor and the timer motor ...

Страница 6: ... be removed from the Motor Disconnect the Motor leads Withdraw the black headed pin 537 Exert an anti clockwise force to disconnect the bayonet fitting between the Fan Access Cover 447 and the back of the Banjo Assy 440 From underneath the dryer withdraw the 4 screws 396 securing the Motor Bracket 432 to the cabinet base Lift out the Motor and Fan Assy Special tool 7813 002 61111 is recommended wh...

Страница 7: ... Bearing Assy 270 to the Back Panel 24 Withdraw the 8 screws securing the Back Panel 24 to the Cabinet 196 Disengage the T piece Grommet from the slot in the Back Panel and lift off The Rear Seal 14 can be prised off the inside of the Back Panel 24 with a screw driver but care should be taken not to damage the inner sheet metal flange Remove excess adhesive before fitting the replacement Rear Sear...

Страница 8: ...e timer Does motor start Exchange timer Does motor start No No No Exchange door relay PCB Does motor start Check br w wiring from RFI filter to door switch Check connections clean and tight does motor start Yes Yes Yes Yes Refit capacitor change motor No Yes Yes Yes Yes No No No No No No Yes Yes No No No Yes Yes No No Yes Yes With motor running does gas attempt to light Does gas light Does gas sta...

Страница 9: ...at CAUTION IT IS LIVE Is voltage between heat selector switch and TB N 230v Exchange both exhaust thermostats 150 C and 60 C and inlet thermostat 130 C brown wires Does control spark Does control spark with high heat selected Ja No No No No No No No Yes Exchange timer Does control spark Does control spark with low heat selected Change 50 C exhaust thermostat Does control spark Exchange heat select...

Страница 10: ... control is sparking Remove plinth 199 Can gas be lit manually Start Check spark gap continuity of H T lead and electrode not cracked Does burner light Exchange control unit Does gas light No Yes Yes Does gas stay on Yes No Whilst control is sparking is voltage at gas control relay PCB terminal T1 230v Yes No Check gas control relay wiring Exchange if wired correctly Does gas light Yes Check wirin...

Страница 11: ...lbow and plinth attached correctly Exchange full sequence control and or gas control relay PCB and or thermostats as necessary until gas stays on Is weight of load suitable Is filter clean Is vent hose or terminal unobstructed Is vent terminal unaffected by wind conditions that may cause back pressure Start No No No No Check gas pressure with all other appliances in operation does gas stay ON Rect...

Страница 12: ...12 WHITE KNIGHT ECO 43A_ CROSSLEE P L C ...

Страница 13: ...403 394 369 196 386 248 370 376 199 11 10 WHITE KNIGHT ECO 43A_ EXPLODED VIEW 1 357 354 362 201 203 366 365 364 363 203a 359 367 13 CROSSLEE p l c 353 352 211 391 235 372 213 249a 249b 497 ...

Страница 14: ... 17 393 375 230 38 389 375 18 375 20 23 21 22 412 375 19 403 396 24 25 26 27 25 14 13 143 398 28 141 408 409 410 411 144 WHITE KNIGHT ECO 43A CROSSLEE P L C EXPLODED VIEW 2 REAR ASSEMBLY VIEWED FROM FRONT 14 ...

Страница 15: ...248 440 442 441 445 446 447 448 356 250 229 406 13 32 29 30 31 456 458 459 445 454 455 457 WHITE KNIGHT ECO 43A_ CROSSLEE P L C EXPLODED VIEW 3 INTERNALS VIEWED FROM REAR 15 ...

Страница 16: ...WHITE KNIGHT ECO 43A_ CROSSLEE P L C EXPLODED VIEW 4 INTERNALS VIEWED FROM REAR 142 112 101 101a 427 266 444 125 270 16 432 ...

Страница 17: ...375 39 41 33 482 411 45 31 13 32 White Knight ECO43A_ Crosslee plc Exploded View 5 17 ...

Страница 18: ...2 39 Ignition Electrode 4213 092 08491 5 41 M4 x 10 Pan Screw 2522 180 40002 5 45 Solenoid Coil SCEM 4213 092 08501 5 101 Motor and Capacitor Assembly 4213 092 25611 4 101a Motor Ceset Olmo see 101 4 112 Capacitor 8µf 4213 092 08091 4 125 Drive Belt 4213 092 18601 4 141 Mains Cable 4213 076 35123 2 142 Terminal Block 4213 078 44613 4 143 Interference Filter 4213 078 52551 2 144 Earth Tab 4213 092 ...

Страница 19: ...35651 1 2 408 Cable Clamp 2 4213 077 47303 2 409 Washer M5 Form A 2522 604 60002 2 409 M5 Form A Washer 2522 604 60002 3 410 Screw 6 x 1 2 2522 165 20004 2 411 M4 Hex Nut 2522 402 50001 2 5 412 Screw No 10 24 UNC x 3 8 8213 130 31051 2 427 Motor Retaining Clips 4213 078 4536_ 4 432 Motor Mounting Bracket 4213 080 0675A 4 434 Loom Strap 4213 078 46311 3 435 M8 Shakeproof Washer 8213 130 28961 3 436...

Страница 20: ...BG43A_ PARTS LIST Bearing Pads Brush Seal Kit 4213 092 21171 Manufactured by Crosslee plc Lightcliffe Factory Hipperholme Halifax West Yorkshire HX3 8DE ECO 43A_ Installation Service Book 4213 094 79351 ...

Отзывы: