background image

GENERAL

Front  loading  tumble  dryer  with  gas  heating.  Reverse 
action  drum  tumble.Time  control.  2-temperature  exhaust 
thermostat  control.Induced  air  flow  enters  dryer  through 
front  grille,  some  passes  through  the  gas  burner  into  the 
rear  ducting  and  some  into  the  cooling  passages,  this 
mixed  air  enters  the  drum  through  the  rear  perforations, 
passes  through  the  clothes,  lint  filter,  and  the  fan  and  is 
discharged through the vent at the rear.

CONNECTIONS
Gas pressure:Rp 1/2 (1/2”B.S.P.parallel internal thread).
Nominally 20mbar
Electric: 230V.50 Hz, earthed supply, 13A fuse.
(wall  socket  must  have  efficient  earth  connection  and 
correct polarity)

DIMENSIONS
Height 85 cms.(33 1/2”)
Width  59.6 cms.(23 5/8”)
Depth 57 cms.(22 1/2”)
Depth when rear vent hose assembled 60cms.(23 5/8”)

WEIGHT
With packing 37 kg
Without packing 36 kg

SUPPORT
Machine rests on 2 rear positioned rollers and 2 non
adjustable feet.

AIR-FLOW
Approximately 120 cubic metres per hour with capacity
clothes load.

IDENTITY
Manufacture date, and serial number are displayed on a
plate revealed when machine door is open.
The  first  4  numerals  identify  year  and  week  of 
manufacture.
The  last  6  numerals  identify the  machine.ALL
INFORMATION FROM THIS PLATE SHOULD BE
QUOTED IN ANY SERVICE COMMUNICATION.

COMPONENTS

DRIVE MOTOR
Permanent split capacitor (8µF)4 pole—Approx. 1/8 HP
Overload protection approx.130°C

BURNER
Pressed steel with slotted flame perforations.
Heat input:3.0kW (10235 Btu/hr).Injector 1.32 mm dia.
 

3

CONTROL

Type:Pactrol full sequence flame control, P16AGTD(CE)
414601. Ignition electrode gap to burner 3 to 4mm Flame
failure electrode (4213 078 52641).Height from heater
base to centre of electrode 27.0±0.5mm.

INLET THERMOSTAT
(Brown wires identification)
Bi-metal contacts normally closed.
Contacts open if airflow restricted.
Contacts open 130°C ±3°C
Contacts reset 100°C ±5°C

INLET TEMPERATURE LIMITER
(White wires identification)
Bi-metal contacts normally closed.
Contacts open if INLETTHERMOSTATfails.
Contacts open 143°C ±3°C
Contacts reset 100°C ±5°C

EXHAUST THERMOSTATS
Bi-metal contacts normally closed.
Normal Fabrics:Contacts open 60°C ±3°C
60°C (green spot Contacts reset 49°C ±4°C
identification)
Delicate Fabrics:Contacts open 50°C ±3°C
50°C (red spot Contacts reset 35°C ±3°C
identification)

DRUM
Volume 105 litres
Speed approx.50/59 r.p.m.
Capacity 7 kg dry cotton
Rotation clockwise 5 mins., anticlockwise 10 secs

TRANSMISSION
Poly-vee belt driven by vee-grooved motor pulley to outer
circumference of drum.

TIMER
Electric 140 minutes combined forward and reverse 5
min cycle with 10 seconds reverse.

HEATER SWITCH
Single pole, ON/OFF, PUSH-PUSH

R.F.I.FILTER
0.1µF +2x2x5mH +2M2

ACCESSORIES
VENT HOSE ASSEMBLY0312 001 01001
WALL/WINDOW VENT KIT0312 005 01001
STACKING KIT0312 003 01001
RESTRAINING KIT0312 006 01001

TECHNICAL DATA  

Содержание ECO 43A

Страница 1: ...stallation and Use Regulations 1998 Guidance may be obtained from the relevant parts of B S 7624 B S 5440 parts 1 and 2 B S 6891 current editions I E E Wiring Regulations and relevant Building Regulations Failure to install the appliance correctly could invalidate the warranty liability claims and could lead to prosecution FOR USE IN THE UNITED KINGDOM AND IRELAND WITH NATURAL GAS ONLY I2H GAS SUP...

Страница 2: ...CTIVE LVD 2006 95 EC EN60 335 1 EN60 335 2 11 GAS APPLIANCE DIRECTIVE GAS 90 396 EEC BS 5258 PART 17 1992 EN 1458 1 2000 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2004 108 EC EN55014 EN 61000 3 2 EN 61000 3 3 EN 50366 2 WARNING THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH THE LOCAL REGULATIONS IN FORCE AND ONLY IN A WELL VENTILATED SPACE READ THE INSTRUCTIONS BEFORE USING OR INSTALLING THIS ...

Страница 3: ...r 8µF 4 pole Approx 1 8 HP Overload protection approx 130 C BURNER Pressed steel with slotted flame perforations Heat input 3 0kW 10235 Btu hr Injector 1 32 mm dia 3 CONTROL Type Pactrol full sequence flame control P16AGTD CE 414601 Ignition electrode gap to burner 3 to 4mm Flame failure electrode 4213 078 52641 Height from heater base to centre of electrode 27 0 0 5mm INLET THERMOSTAT Brown wires...

Страница 4: ...urniture and similar surfaces 4 VENTING The dryer must be fitted with an exhaust vent hose and the end either hung out of a window or fitted to a wall window vent connection Note Do not obstruct or add a mesh to the vent hose outlet during use and ensure that it cannot be blocked or bent sharply which obstruct the air flow It is recommended that the interior of the hose be periodically inspected a...

Страница 5: ...arried out it should be carried out by a competent person i e registered Engineer 9 STACKING Instructions for stacking if required are supplied with the stacking kit PROGRAMME Clockwise rotation of the control knob closes switch contacts within the timer to a energise the drive motor and b energise the full sequence flame controller The timer switch controlling the drive motor and the timer motor ...

Страница 6: ... be removed from the Motor Disconnect the Motor leads Withdraw the black headed pin 537 Exert an anti clockwise force to disconnect the bayonet fitting between the Fan Access Cover 447 and the back of the Banjo Assy 440 From underneath the dryer withdraw the 4 screws 396 securing the Motor Bracket 432 to the cabinet base Lift out the Motor and Fan Assy Special tool 7813 002 61111 is recommended wh...

Страница 7: ... Bearing Assy 270 to the Back Panel 24 Withdraw the 8 screws securing the Back Panel 24 to the Cabinet 196 Disengage the T piece Grommet from the slot in the Back Panel and lift off The Rear Seal 14 can be prised off the inside of the Back Panel 24 with a screw driver but care should be taken not to damage the inner sheet metal flange Remove excess adhesive before fitting the replacement Rear Sear...

Страница 8: ...e timer Does motor start Exchange timer Does motor start No No No Exchange door relay PCB Does motor start Check br w wiring from RFI filter to door switch Check connections clean and tight does motor start Yes Yes Yes Yes Refit capacitor change motor No Yes Yes Yes Yes No No No No No No Yes Yes No No No Yes Yes No No Yes Yes With motor running does gas attempt to light Does gas light Does gas sta...

Страница 9: ...at CAUTION IT IS LIVE Is voltage between heat selector switch and TB N 230v Exchange both exhaust thermostats 150 C and 60 C and inlet thermostat 130 C brown wires Does control spark Does control spark with high heat selected Ja No No No No No No No Yes Exchange timer Does control spark Does control spark with low heat selected Change 50 C exhaust thermostat Does control spark Exchange heat select...

Страница 10: ... control is sparking Remove plinth 199 Can gas be lit manually Start Check spark gap continuity of H T lead and electrode not cracked Does burner light Exchange control unit Does gas light No Yes Yes Does gas stay on Yes No Whilst control is sparking is voltage at gas control relay PCB terminal T1 230v Yes No Check gas control relay wiring Exchange if wired correctly Does gas light Yes Check wirin...

Страница 11: ...lbow and plinth attached correctly Exchange full sequence control and or gas control relay PCB and or thermostats as necessary until gas stays on Is weight of load suitable Is filter clean Is vent hose or terminal unobstructed Is vent terminal unaffected by wind conditions that may cause back pressure Start No No No No Check gas pressure with all other appliances in operation does gas stay ON Rect...

Страница 12: ...12 WHITE KNIGHT ECO 43A_ CROSSLEE P L C ...

Страница 13: ...403 394 369 196 386 248 370 376 199 11 10 WHITE KNIGHT ECO 43A_ EXPLODED VIEW 1 357 354 362 201 203 366 365 364 363 203a 359 367 13 CROSSLEE p l c 353 352 211 391 235 372 213 249a 249b 497 ...

Страница 14: ... 17 393 375 230 38 389 375 18 375 20 23 21 22 412 375 19 403 396 24 25 26 27 25 14 13 143 398 28 141 408 409 410 411 144 WHITE KNIGHT ECO 43A CROSSLEE P L C EXPLODED VIEW 2 REAR ASSEMBLY VIEWED FROM FRONT 14 ...

Страница 15: ...248 440 442 441 445 446 447 448 356 250 229 406 13 32 29 30 31 456 458 459 445 454 455 457 WHITE KNIGHT ECO 43A_ CROSSLEE P L C EXPLODED VIEW 3 INTERNALS VIEWED FROM REAR 15 ...

Страница 16: ...WHITE KNIGHT ECO 43A_ CROSSLEE P L C EXPLODED VIEW 4 INTERNALS VIEWED FROM REAR 142 112 101 101a 427 266 444 125 270 16 432 ...

Страница 17: ...375 39 41 33 482 411 45 31 13 32 White Knight ECO43A_ Crosslee plc Exploded View 5 17 ...

Страница 18: ...2 39 Ignition Electrode 4213 092 08491 5 41 M4 x 10 Pan Screw 2522 180 40002 5 45 Solenoid Coil SCEM 4213 092 08501 5 101 Motor and Capacitor Assembly 4213 092 25611 4 101a Motor Ceset Olmo see 101 4 112 Capacitor 8µf 4213 092 08091 4 125 Drive Belt 4213 092 18601 4 141 Mains Cable 4213 076 35123 2 142 Terminal Block 4213 078 44613 4 143 Interference Filter 4213 078 52551 2 144 Earth Tab 4213 092 ...

Страница 19: ...35651 1 2 408 Cable Clamp 2 4213 077 47303 2 409 Washer M5 Form A 2522 604 60002 2 409 M5 Form A Washer 2522 604 60002 3 410 Screw 6 x 1 2 2522 165 20004 2 411 M4 Hex Nut 2522 402 50001 2 5 412 Screw No 10 24 UNC x 3 8 8213 130 31051 2 427 Motor Retaining Clips 4213 078 4536_ 4 432 Motor Mounting Bracket 4213 080 0675A 4 434 Loom Strap 4213 078 46311 3 435 M8 Shakeproof Washer 8213 130 28961 3 436...

Страница 20: ...BG43A_ PARTS LIST Bearing Pads Brush Seal Kit 4213 092 21171 Manufactured by Crosslee plc Lightcliffe Factory Hipperholme Halifax West Yorkshire HX3 8DE ECO 43A_ Installation Service Book 4213 094 79351 ...