Power Switch

The new series WhisperKOOL units come
equipped with an On/Off switch. The
On/Off switch is simply used when the
owner does not need to utilize the
equipment. 

NOTE

; (It will take five minutes before

the unit begins to operate once the
switch is placed in the “On” position. This
is due to the designed safety delay in the
PDT thermostat.)

Condensate Evaporator Switch

The Condensate Evaporator is a heating
element that automatically evaporates
excess condensate that accumulates in the
cooling system as a by-product of
refrigeration. Like most cooling systems,
WhisperKOOL uses heat from the
compressor to evaporate and eliminate the
majority of the water that accumulates
during normal use. However, during
certain weather conditions or in humid
areas (above 80%), more condensate will
accumulate than the cooling system can
evaporate with heat from the compressor
alone. Only the WhisperKOOL units are
equipped with sophisticated heating
elements that automatically sense the
presence of water and work continually
until the water is gone.

Setting the Condensate Evaporator to the
“On” setting causes the heating element to
operate whenever water is present in the
compressor pan.

If your wine cellar is located in a dry
climate, there is a good chance that the
unit will not accumulate excessive water.
Therefore, elect to save electricity by
setting the Condensate Evaporator to the
“AUTO” position.

Using the WhisperKOOL

System

-10-

USING THE WHISPERKOOL SYSTEM

¤

Location of control switches

Switches

Drain Line

All units come with a drain line for
additional removal of excessive
condensate. This is a back up system to
the Condensate Evaporator. If the unit is
installed in a high humidity area of the
country, it is mandatory to install the
drain line attachment. In high humidity,
the cooling unit will strip excess water
from the air in order to maintain the
proper level of humidity within the cellar.
The Condensate Evaporator will heat and
dissipate the excess moisture through the
rear of the unit. However in extreme
humidity, additional condensate will be
created. Conversely the high humidity air
has less capacity to absorb additional
moisture through the exhaust of the unit.
Thus the drain line will prevent overflow
and leaking by allowing for discharge of
the additional condensate.

Содержание WK 1600

Страница 1: ...XLT WhisperKOOL Owner s Manual Protecting Your Investment In Fine Wines...

Страница 2: ...art without the written consent of Vinoth que Wine Cellars Every effort has been made to ensure that the information in this manual is accurate Vinoth que Wine Cellars is not responsible for printing...

Страница 3: ...eshooting Guide 15 Solutions to Common Problems 15 Technical Assistance 20 How to Contact Customer Service 20 Warranty Clarification on WhisperKOOL Product 21 Limits and Exclusions 21 Vinoth que Custo...

Страница 4: ...to 70 F It is designed to cool 30 F cooler than the ambient temperature of the space it is exhausting to Humidity Control There are no separate controls for maintaining proper humidity Humidity is ma...

Страница 5: ...nal unit to be picked up In some instances an inspection must take place at the point of receipt in which case you will be contacted by the shipping company to schedule an appointment to inspect the d...

Страница 6: ...available We have put together some useful tips to assist in the installation process Our recommendations are meant to act as a guide in the process of building a proper enclosure Your intended locati...

Страница 7: ...ly cool environment by capturing the warm air and replacing it with cool air Mounting the unit low in the room will result in a temperature variation in the room due to the unit s inability to draw wa...

Страница 8: ...a fresh air inlet as well Do not attempt to install ducting on the unit The fans are not designed for ducting and will result in premature failure of the unit Unobstructed Airflow Unobstructed airflo...

Страница 9: ...e WhisperKOOL warranty Do not use a Ground Fault Interrupter GFI with this product The cooling unit will draw more amperage than the GFI will allow Upon plugging the unit in and turning it on there wi...

Страница 10: ...before running cool Once the operation has been tested turn the unit off unplug the unit from the electrical outlet and remove the by pass plug Note If the system does not seem to be running cool afte...

Страница 11: ...o the mounting bracket Wall Stud Two by Four Upper Support Wall Stud 2 x 4 Lower Support Electrical Outlets Drain line Installing Thermostat Attach the thermostat to the front of the unit using the mo...

Страница 12: ...etting the Condensate Evaporator to the On setting causes the heating element to operate whenever water is present in the compressor pan If your wine cellar is located in a dry climate there is a good...

Страница 13: ...ually communicates back and forth to the thermostat This results in a consistent temperature setting and accuracy 2 Built in Defrost Cycle The unit is designed to shut off for five minutes every ninet...

Страница 14: ...ash rapidly if there is no probe connected to the thermostat Buttons To change the set point temperature press either the or button The SET light will flash once for each 1 F the set point is changed...

Страница 15: ...nt the unit to maintain 7 UP Arrow Button Used with the SET button to set temperature higher In addition by pressing and holding the button it will allow you to see the 5 minute count down 8 DOWN Arro...

Страница 16: ...uipment Wine cellar cooling systems are highly specialized and designed for one purpose only long term storage of wine Maintenance The following maintenance should be performed on your WhisperKOOL uni...

Страница 17: ...rear intake grills This will restrict the airflow and may affect the unit s ability to function properly Periodically cleaning the unit s vents will help assure maximum cooling efficiency Airflow Prop...

Страница 18: ...fifteen minutes and measure the air temperature coming from the circulating fans in front of the unit If Precision digital Technology Therm ostat PDT 55 F WINE ON SET Temperature SET the air temperat...

Страница 19: ...meter to measure the temperature of air coming out of the WhisperKOOL unit s front fans If it is cooling the room then the problem may lie with the thermostat If the WhisperKOOL unit cools the room wi...

Страница 20: ...uidelines Your options to resolve this problem are either to send the unit back to the factory or disassemble the unit and clear the clogged drain line yourself However unauthorized repairs will void...

Страница 21: ...talled on the circuit breaker In addition the unit may not be used on an electrical line with a Ground Fault Interrupter GFI The WhisperKOOL will draw more amperage than the GFI will allow Consumer Ca...

Страница 22: ...you call The model and serial number of your WhisperKOOL unit Type of thermostat used with your WhisperKOOL Location and installation details such as ventilation construction and size of room How To C...

Страница 23: ...to address all of the variables associated with proper installation will cause the unit to operate incorrectly and limit its ability to cool and the longevity of the unit itself Follow Troubleshootin...

Страница 24: ...the shipping document Please contact Vinoth que Customer Service to assist in filing a damage claim Damage must be reported within 15 days 2 In the event that the consumer has received a unit that is...

Страница 25: ...t cover damage due to improper operation or maintenance connection to improper voltage supply or attempted repair by anyone other than Vinoth que to service the Product This warranty does not cover Pr...

Страница 26: ......

Страница 27: ......

Страница 28: ...1738 East Alpine Avenue Stockton California 95205 www vinotheque com...

Отзывы: