2  INSTALLATION  

 

2.1 

GENERAL 

To  ensure  reliability  and  durability  of  the  equipment,  it  is 
very  important  that  the  installation  is  carried  out  with  the 
utmost  care  and  attention.  To  avoid  problems,  such  as 
temperature  problems,  noise  levels,  vibration,  extreme 
wear out, etc. the instructions set out in this manual must 
be  followed  and  all  installation  work  must  be  carried  out 
professionally.  
 

2.2 

LOCATION  

When  looking  for  a  proper  place  for  the  generator  in  a 
vehicle all relevant aspects have to be taken into account: 
 

Generator  

 

Accessibility:  When  selecting  the  location  area  in 
which  to  mount  the  generator,  make  sure  there  is 
sufficient  room  to  carry  out  any  maintenance  work. 
The unit must be easily accessible on the distribution 
side to have access to the V-belt.  

 

Create a solid mounting position  

 

Find space to mount the generator 

 

In a boat: mount the generator high enough to avoid 
water damage from the bilge. In a vehicle: mount the 
generator  high  enough  to  avoid  damage  from 
splashing water and dirt from the road. 

  

Inverter 

 

Accessibility: Take care one has access to the control 
on the inverter box. When using a remote control this 
will be less important. 

 

Find  a  dry  and  clean  place  protected  from  strong 
vibrations.  Do  not  expose  the  Inverter  Box  to  rain, 
snow, spray, bilge water or dust. 

 

Mount the inverter box not too far from the generator 
to keep the cables short 

 

Provide fresh air for cooling. Do not cover or obstruct 
the  ventilation  openings.  Overheating  may  cause 
malfunction. Do not install the Inverter Box in a zero-
clearance  compartment.  This  may  result  in  over-
heating.  

 

The inverter contains components which can produce 
arcs  or  sparks.  To  prevent  fire  or  explosion  do  not 
install  in  compartments  containing  batteries  or 
flammable  materials  or  in  locations  which  require 
ignition protected equipment. This includes any space 
containing gasoline-powered machinery, fuel tanks or 
joints,  fittings  and  other  connections  between 
components of the fuel system. 

 
 
 
 

Remote control 

An optional remote control is available and can be mounted 
on the dashboard of the vehicle/boat, or in  another place 
from where one wants to operate the Belt-Power. 
 

2.3 

VENTILATION  

The inverter normally draws air from the compartment and 
circulates the air, that will be warm when coming out. The 
same is true for the generator. 
With  natural  ventilation  the  compartment  must  have 
ventilation openings of adequate size and location to enable 
the inverter and generator to operate without overheating.  
On cars the generator will be cooled by air in the relative 
open  engine  compartment.  In  boats  the  engine 
compartment could be almost closed. When this is the case 
the instructions below must be followed.  
A  "sealed"  compartment  must  have  a  good  extraction 
ventilator  to  maintain  reasonable  temperatures.  High 
temperature  ambient  air  reduces  inverter/generator 
performance.  To  minimise  these  effects  the  room 
temperature must not be more than 15ºC above the outside 
ambient air temperature.  
Apply a combination of ventilators, blowers and air intake 
ducting  to  meet  the  temperature  limit.  The  air  inlet  ducts 
should  run  to  the  bottom  of  the  compartment  to  circulate 
fresh air. Air outlets should be at the top of the compartment 
to remove the hottest air. A compartment blower should be 
used  as  an  extraction  ventilator  to  remove  air  from  the 
compartment.  
In cases where it is impossible to meet the above mentioned 
temperature  limit  by  using  compartment  ventilation, 
connections are to be made for an air inlet directly to the 
inverter/generator. 

With 

these 

connections 

the 

inverter/generator can be directly connected to an air duct. 
Air inlets should be louvered, where appropriate, to protect 
the room and to protect the generator from rain and water 
spray. 
 

2.4 

CONNECTIONS 

Shielded cable 

The belt driven generator comes with the special shielded 
cable between generator and inverter. The connections are 
marked 1 to 5 as shown in figure 2. The inner copper shield 
is used for grounding (yellow/green) Refer to 2.8 for details.  
 

 

Figure 2:  Shielded cable 

Содержание 41301000

Страница 1: ...er belt driven generator W BD 3 5 W BD 5 230V 50Hz WHISPER POWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel 31 512 571550 Fax 31 512 571599 www whisperpower eu V1 June 2010 Art nr 40200591 V3 1 November 2011 Art nr 40200591 ...

Страница 2: ...en generator 3 1 2 1 Belt driven generators 3 1 2 2 How does it work 3 2 INSTALLATION 4 2 1 General 4 2 2 Location 4 2 3 Ventilation 4 2 4 Connections 4 2 5 Low voltage DC control system 6 2 6 Control 6 2 7 AC power system 230 volt 6 2 8 Connecting the cables 7 2 9 Installation of the generator 9 2 10 Dimensional drawings 13 ...

Страница 3: ...y loss of at least 20 a transformer loss of 10 Especially when high power is needed from 2 kW up to 5kW the belt driven generator system is superior For some applications where power is needed while the vehicle cannot run or when the engine runs at a too low speed RPM a combination with a battery based inverter charger COMBI system is recommended While the engine is not running or running at too l...

Страница 4: ...ther connections between components of the fuel system Remote control An optional remote control is available and can be mounted on the dashboard of the vehicle boat or in another place from where one wants to operate the Belt Power 2 3 VENTILATION The inverter normally draws air from the compartment and circulates the air that will be warm when coming out The same is true for the generator With n...

Страница 5: ...INSTALLATION EN W BD3 5 W BD5 BeltPower October 2011 5 Fuse W BD 3 5 10 Amp W BD 5 12 15 Amp Figure 1 general lay out of the system ...

Страница 6: ...inverter box A remote control is optional A 5 m intermediate 8 pole communication cable comes with the remote control refer to figure 3 The control both on the case and the remote has an on off switch a scroll button 4 LEDs that will signals an alarm if something is wrong only on the inverter box and a display showing specific information on the status of the system warnings and alarms Refer to th...

Страница 7: ...that control the output On the generator the wires has to be fastened with screws M3x1 5 Do not fasten too tight apply a torque wrench and apply a maximum torque 0 3 0 5 Nm The cable has to be connected to the inverter with the connecter in the delivery accordingly to picture 8 below 3 POWER SUPPLY The inverter needs 12V from the battery to control the electronic system A two wire 2 5mm2 cable not...

Страница 8: ...verter to be made by the yellow green wires that is connected to in inner copper sheet of the shielded cable inverter Also the 230 v output cable should have a yellow green wire for grounding The L1 and 0 of the 230V AC output wiring are NOT grounded To make a connection between neutral and ground of the AC 230V output could be necessary as part of a specific insulation failure protection system T...

Страница 9: ... at full speed will be 13 500 RPM 3x4500 rpm This is below 15000 rpm and is OK Example 2 When one need 3 kW at idle speed the generator must have 3500 RPM The Pulley ratio must be 4 4 At full speed the generator rpm will be 19 800 RPM 4 4x4500 this is too much and is NOT OK Max power at idle will be 15000 4500 3 33x800 RPM 2 8 kW Further more the engine must be capable to bring 2 8 kW at 800 RPM I...

Страница 10: ...BD3 5 W BD5 BeltPower EN SPEED POWER DIAGRAMS SPEED AND ELECTRIC OUTOUT POWER MEASURED FOR THE 3 5Kw MODEL AT 230V SPEED AND ELECTRIC OUTOUT POWER MEASURED FOR THE 5Kw MODEL AT 230V Figure 12 speed power diagrams W BD 5 5 kW Watt Watt ...

Страница 11: ...3 Pulley 4 Position ring 5 Fixing plate 6 Bearing The washers for alignment should be placed on the large support washer 1 to transfer the force to the shaft The pulley must press on the position ring and the indirectly on the bearing Without this transmission of the force to the shaft the lifetime of the generator will be decreased extremely 5 Brackets There are many vehicles on the market and ev...

Страница 12: ...loose will reduce the life of the belt and generator and will impair the performance of the generator 6 Pulleys A poly V belt pulley with 6 groves and a diameter of 60 mm and an overhang of 5 mm refer to the figure 14 is recommended A 6 grove pulley 50 mm is the minimum diameter that can be applied Other pulleys are available on request When applying a double grove classic V belt a diameter of 75 ...

Страница 13: ...2 10 DIMENSIONAL DRAWINGS Figure 17 ...

Страница 14: ...DIMENSIONAL DRAWINGS 14 November 2011 W BD3 5 W BD5 BeltPower EN Figure 18 dimensions inverter box W BD3 5 and W BD 5 ...

Страница 15: ...DIMENSIONAL DRAWINGS EN W BD3 5 W BD5 BeltPower October 2011 15 Figure 19 dimensions remote control ...

Страница 16: ...Kelvinlaan 82 9207 JB Drachten The Netherlands www whisperpower com sales whisperpower nl ...