38
Water Filtration System
Model P9WB2L/P9RFWB2L Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53, 401, and CSA B483.1 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as speci
fi
ed in NSF/ANSI Standa rds 42, 53, 401, and CSA B483.1.
Substance Reduction Aesthetic
Effects
*OnVFOU$IBMMFOHF$PODFOUSBUJPO
Maximum Permissable Product
Water Concentration
Average % Reduction
Chlorine Taste/Odor
2.0 mg/L ± 10%
50% reduction
9 7.0%
Particulate Class I*
At least 10,000 particles/mL
85% reduction
>99.9%
Contaminant Reduction
*OnVFOU$IBMMFOHF$PODFOUSBUJPO
Maximum Permissable Product
Water Concentration
Average % Reduction
Lead: @ pH 6.5 / @ pH 8.5
0.15 mg/L± 10%
0.010 mg/L
>99.3%/98.6%
Benzene
0.015 mg/L ± 10%
0.005 mg/L
93.8%
p-Dichlorobenzene
0.225 mg/L ± 10%
0.075 mg/L
99.8%
Carbofuran
0.08 mg/L ± 10%
0.040 mg/L
81.9%
Toxaphene
0.015 ± 10%
0.003 mg/L
>95%
Atrazine
0.009 mg/L ± 10%
0.003 mg/L
87.0%
Asbestos
10
7
to 10
8
fi
bers/L††
99%
>99%
Live Cysts†
50,000/L min.
99.95%
>99.99%
Turbidity
11 NTU ± 10%
0.5 NTU
96.9%
Lindane
0.002 ± 10%
0.0002 mg/L
>99.2%
Tetrachloroethylene
0.015 mg/L ± 10%
0.005 mg/L
96.6%
O-Dichlorobenzene
1.8 mg/L ± 10%
0.60 mg/L
92.3%
Ethylbenzene
2.1 mg/L ± 10%
0.70 mg/L
86.9%
1,2,4-Trichlorobenzene
0.210 mg/L ± 10%
0.07 mg/L
>99.8%
2,4 - D
0.210 mg/L ± 10%
0.07 mg/L
88.5%
Styrene
2.0 mg/L ± 10%
0.1 mg/L
99.6%
Toluene
3.0 mg/L ± 10%
1.0 mg/L
93.5%
Endrin
0.006 mg/L ± 10%
0.002 mg/L
81.7%
Atenolol
200 ± 20%
30 ng/L
95.7%
Trimethoprim
140 ± 20%
20 ng/L
96.1%
Linuron
140 ± 20%
20 ng/L
96.3%
Estrone
140 ± 20%
20 ng/L
95.3%
Nonylphenol
1400 ± 20%
200 ng/L
95.5%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to
22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certi
fi
ed under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
■
It is important that operational, maintenance, and
fi
lter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
■
The disposable cartridge must be changed at least every 6 months.
■
Use replacement
fi
lter P9RFWB2L, part #EDR2RXD1/EDR2RXD1B.
2015 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices
are subject to change without notice.
■
The
fi
lter monitor system measures the amount of water that passes
through the
fi
lter and alerts you when it is time to replace the
fi
lter.
Refer to the “Using the Controls” or “Water Filtration System” section
(in the User Instructions or User Guide) to learn how to check the
water
fi
lter status.
■
After changing the water
fi
lter,
fl
ush the water system. See “Water
and Ice Dispensers” or “Water Dispenser” in the User Instructions or
User Guide.
■
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
■
The product is for cold water use only.
*Class I particle size: >0.5 to <1 um
†
Based on the use of Cryptosporidium parvum oocysts
††
Fibers greater than 10 um in length
®
NSF is a registered trademark of NSF International.
■
The water system must be installed in compliance with state and
local laws and regulations.
■
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certi
fi
ed for cyst reduction may be used on disinfected
waters that may contain
fi
lterable cysts.
EPA Est. No. 082047-TWN-001
■
Refer to the “Warranty” section (in the User Instructions or User
Guide) for the Manufacturer’s limited warranty, name, and telephone
number.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Potable City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.75 gpm (2.84 L/min.) @ 60 psi
System tested and certi
fi
ed by NSF International against NSF/ANSI
Standard 42, Standard 53, Standard 401, and CSA B483.1 for
the reduction of contaminants speci
fi
ed on the Performance
Data Sheet.
PERFORMANCE DATA SHEETS
Содержание WRX735SDHV
Страница 124: ...124 NOTES ...