5-5
Unsuccessful Ac�va�on
If entry into diagnos�c mode is unsuccessful,
refer to the following indica�ons and ac�ons:
Indica�on 1: None of the LED’s or display turn on.
Ac�on: Select any cycle.
�
If indicators come on, try to change the
func�on for the three bu�ons used to ac�vate
the diagnos�c test mode. If any bu�on is
unable to change the func�on, something
is faulty with the bu�on, and it will not be
possible to enter the diagnos�c mode using
that bu�on. Replace the user interface and
housing assembly.
�
If no indicators come on a�er selec�ng the
cycle, go to TEST #1.
Indica�on 2: Console indicators begin flashing
immediately.
Ac�on: If console indicators begin flashing on
and off immediately, replace the user interface.
Ac�va�on with Saved Fault Codes
If there is a saved fault code, it will be flashing
in the display. Review the Fault/Error Codes
table on pages 8–10 for the recommended
procedure. If there is no saved fault code,
“888” will be displayed.
USER INTERFACE TEST (Figure 1)
NOTE: The Service Diagnos�c mode must be
ac�vated before entering the User Interface
Test.
Ac�ve Fault Code Display
in User Interface Test
If the display begins flashing while in User
Interface Test, it is displaying an ac�ve fault
code. Ac�ve fault codes are codes that are
currently detected. Only one ac�ve fault code
can be displayed at a �me.
Entry Procedure
Press and release the 1st bu�on used
to ac�vate Service Diagnos�c mode.
User Interface Test
Pressing bu�ons and rota�ng the cycle
selector knob will turn on/off the corresponding
indicator and sound a beep as shown in figure
1, User Interface Test, pages 2–3. If indicators
do not come on and beep a�er pressing
bu�ons and rota�ng the cycle selector knob,
go to TEST #2: User Interface.
NOTE: A second press of the POWER bu�on
while in User Interface Test mode exits the
Service Diagnos�c mode and returns the
washer to standby mode.
Exit Procedure
To exit User Interface Test, press and hold the
1st bu�on used to ac�vate Service Diagnos�c
mode for 5 seconds.
QUICK DIAGNOSTICS
NOTE: The Service Diagnos�c mode must be
ac�vated before entering Quick Diagnos�cs;
see procedure. If, at any point, the user presses the
power bu�on, the washer exits to standby mode.
Ac�ve Fault Code Display
in Quick Diagnos�cs
If the display begins flashing while in Quick
Diagnos�cs, it is displaying an ac�ve fault
code. Ac�ve fault codes are codes that are
currently detected. Only one ac�ve fault code
can be displayed at a �me.
Entry Procedure
To enter Quick Diagnos�cs, press and release
the 2nd bu�on used to ac�vate the Service
Diagnos�c mode. All LEDs turn off and the
START bu�on begins to flash. Press the START
bu�on to perform the Quick Diagnos�cs tests
listed on page 6. Each test phase is indicated
on the display.
Exit Procedure
When test is complete, press the POWER
bu�on to exit Quick Diagnos�cs and return
to standby mode.
FOR SERVICE TECHNICIAN’S USE ONLY
COMPONENT TESTING (continued)
QUICK DIAGNOSTIC TEST
TEST
PHASE
WASHER FUNCTION
COMPONENT
STEP ENDS…
C00
Door lock motor is actuated. Door
unlocks, and then locks again.
Pump is activated for 15 seconds.
*Door lock system
*Drain Pump
on completion only.
C01
Heater is turned on.
Steam valve is actuated.
* Heater
* Steam Valve
* Temperature Sensor
on completion or at key press.
C02
Cold water valve will actuate.
* Flow Meter
* Cold Water Valve
on completion or at key press.
C03
Dispensing system is set to the
Prewash position.
*Dispenser Motor
*Dispenser Contact
on completion only.
C04
Hot water valve will actuate.
* Hot Water Valve
on completion or at key press.
C05
Drum rotates clockwise at wash
speed.
* Motor
* Motor Control Unit (MCU)
on completion or at key press.
C06
Heater is turned on.
Drum rotates clockwise at wash speed.
The water valve is activated to fill
drum to minimum water volume
required to wash. (If there is enough
water in the drum, the water valve
will not turn on.)
*Heater
*Water Temperature
Sensor
*Pressure Sensor
on completion or at key press.
C07
Drain Pump is actuated until there is
no water in the system—plus an
additional 15 seconds.
* Drain Pump
* Pressure Sensor
on completion only.
C08
Drum rotates counterclockwise
from 35 rpm > 100 rpm > 150 rpm >
100 rpm in 4 minutes.
* Motor
* Motor Control Unit
on completion only.
Drum rotates counterclockwise
at maximum speed.
* Motor
* Motor Control Unit
on completion or at key press.
SOFTWARE VERSION DISPLAY
NOTE: The Soware Version Display mode will
me out aer 5 minutes of user inacvity and
return to standby mode.
Entry Procedure
To enter Soware Version Display, press
and hold the 2nd buon used to acvate the
Service Diagnosc mode for 5 seconds.
Press the START buon to cycle through the
following informaon:
•
CCU (Soware Version, EEPROM Version)
•
UI (Soware Version, EEPROM Version)
•
MCU (Soware Version)
Exit Procedure
Press the POWER buon to exit Soware
Version Display and return to standby mode.
FAULT/ERROR CODES
(Refer to fault/error code charts on pages 8–10.)
Fault/Error Code Display Method
Fault codes are displayed by alternately
showing F# and E#. All fault codes have an
F# and an E#. The F# indicates the suspect
System/Category. The E# indicates the
suspect Component system.
Содержание WFW94HEX Series
Страница 61: ...5 2 FOR SERVICE TECHNICIAN S USE ONLY COMPONENT TESTING continued ...
Страница 76: ...5 17 NOTES ...
Страница 83: ...7 1 WIRING DIAGRAMS WASHER NON STEAM ...
Страница 86: ......