3.
Slowly turn the filter counterclockwise until water flows
out. Let the water flow out, without removing the filter.
When the container is full, close the drain pump filter
by turning it clockwise. Empty the container. Repeat
this procedure until all the water has drained.
4.
Lay a cotton cloth beneath the drain pump filter to absorb
any water still in it. Then remove the drain pump filter by
turning it counterclockwise.
5.
Remove residue from the filter by rinsing with water.
6.
Reinsert the drain pump filter by turning it clockwise.
Make sure to turn it in as far as it will go, with the filter
handle left in a vertical position. To test water tightness of
the drain pump filter, pour about 1 liter of water into the
detergent dispenser. Then reinstall the base panel.