background image

FOR SERVICE TECHNICIAN’S USE ONLY

PART NO. W10054150

TECH SHEET - DO NOT DISCARD

PAGE 6

6.

Access the machine control electronics
without disconnecting any wiring to the
control board. See Accessing &
Removing the Electronic Assemblies,
page 11.

7.

With an ohmmeter, check for continuity
between the L1 terminal of the plug
(found in step 5) and P9-2 (black wire) on
the machine control board. See figure 15,
page 11.

If there is continuity, go to step 8.

If there is no continuity, check that
wires to the terminal block are
mechanically secure. If so, replace the
main wire harness and test the dryer.

8.

Check for continuity between the neutral
(N) terminal of the plug and P8-3 (white
wire) on the machine control board.

If there is continuity, go to step 9.

If there is no continuity and the
mechanical connections of the wire are
secure, replace the main wire harness.

9.

Visually check that the P5 connector is
inserted all the way into the machine
control electronics.

10.

Visually check that the user interface
assembly is properly inserted into the
front console.

11.

If both visual checks pass, replace the
user interface assembly.

12.

Plug in dryer or reconnect power.

13.

Perform the Console Buttons and
Indicators Diagnostic test, page 1, to
verify repair.

14.

If indicators still do not light, the
machine control electronics has failed:

Unplug dryer or disconnect power.

Replace the machine control
electronics.

Plug in dryer or reconnect power.

Perform the Console Buttons and
Indicators Diagnostic test, page 1 to
verify repair.

TEST #2

Machine Control

Power Check

This test is used to determine if power is
present at the machine control electronics.

NOTE:

The drum light is controlled by the

machine control on all models.

1.

Plug in dryer or reconnect power.

2.

Open the door.

If the drum light illuminates, then
power is present at the machine
control. Go to TEST #6, page 10.

If the drum light fails to illuminate,
do not assume the machine control
electronics needs replacement.
Several conditions may cause the
drum light not to illuminate, including
a bad bulb. If the drum light does not
illuminate, go to TEST #1.

11

Figure 2.

Component locations.

TROUBLESHOOTING TESTS

NOTE:

These checks are done with the dryer

unplugged or disconnected from power.

TEST #1

Supply Connections

This test should only be done after
confirming proper voltage at the outlet.

1.

Unplug dryer or disconnect power.

2.

Remove the cover plate from the back of
the dryer. See figure 3.

3.

Make sure the power cord is securely
fastened to the terminal block.

Remove Screw

Cover

Plate

Figure 3.

Remove the cover plate.

4.

With an ohmmeter, check for continuity
between the neutral (N) terminal of the
plug and the center contact on the
terminal block. See figure 4.

If there is no continuity, replace the
power cord and test the dryer.

If there is continuity, go to step 5.

5.

In a similar way, check which terminal of
the plug is connected to the left-most
contact on the terminal block and make a
note of it. This will be L1 (black wire) in
the wiring diagram. See figure 4 and the
appropriate wiring diagram, page 4.

When this is found, go to step 6.

If neither of the plug terminals have
continuity with the left-most contact of
the terminal block, replace the power
cord and test the dryer.

COM

N

L1

Power Cord

Plug

Terminal Block

Figure 4.

Plug-to-terminal connections.

Содержание WED6200SW1

Страница 1: ...ith all indicators off or with only the Clothes Dry indicator on 2 Select any one button except Pause Cancel and follow the steps below using the same button remember the button Press hold 2 5 seconds Release for 2 5 seconds Press hold 2 5 seconds Release for 2 5 seconds Press hold 2 5 seconds 3 If this test mode has been entered successfully all indicators on the console are illuminated for 5 sec...

Страница 2: ...lluminated to indicate the airflow range corresponding to the number displayed The More LED will be illuminated for airflow readings above 40 cfm The Normal LED will be illuminated for airflow readings between 29 and 40 cfm The Less LED will be illuminated for airflow readings less than 29 cfm If airflow value is low check to make sure the lint screen is clean the door seal is in place and the ven...

Страница 3: ...re the lint screen is clean the door seal is in place and the vent is not obstructed DISPLAY FAULT CODES The fault codes below would be indicated when attempting to start a drying cycle or after activating the diagnostic test mode PROBLEM POSSIBLE CAUSE TEST NOTE Possible Cause Tests MUST be performed in the sequence shown for each problem WON T POWER UP No response when buttons are pressed 1 Supp...

Страница 4: ...INE CONTROL ELECTRONICS P4 2 P4 1 R R INLET THERMISTOR 50k Ω INLET TEMP INLET TEMP RTN BU P8 1 LAMP LOAD P8 2 GND CENTRIFUGAL SWITCH 2M 1M 5M 6M 3M R LINE L2 W DOOR SWITCH W NEUTRAL N T BU BU W W P8 4 P8 3 NEUTRAL P9 1 P8 5 BK W THERMAL FUSE 196 F 91 C 4M DRIVE MOTOR 1 3 H P MAIN 1 4 2 6 Ω START 1 4 2 8 Ω SENSOR DOOR NEUTRAL MOTOR MTR CS MOIST MOIST RTN MODEL MODEL RTN OUTLET TEMP OUTLET TEMP RTN ...

Страница 5: ...W BK THERMAL CUT OFF 309 F 154 C HEATER 2700 W G Y R 240 VOLTS HEATER RELAY 1 HEATER RELAY 2 COM BK BK HEATER 2700 W R V INLET TEMP INLET TEMP RTN P4 3 P4 6 R R 10k Ω P4 2 P4 1 R R 50k Ω EXHAUST THERMISTOR INLET THERMISTOR NC HIGH LIMIT THERMOSTAT 180 F 82 C V R HEATER DUAL ELEMENT STRIP CIRCUIT CENTRIFUGAL SWITCH 2M 1M 5M 6M 3M W DOOR SWITCH T BU BU W P8 4 P9 1 THERMAL FUSE 196 F 91 C 4M DRIVE MO...

Страница 6: ...s test is used to determine if power is present at the machine control electronics NOTE The drum light is controlled by the machine control on all models 1 Plug in dryer or reconnect power 2 Open the door If the drum light illuminates then power is present at the machine control Go to TEST 6 page 10 If the drum light fails to illuminate do not assume the machine control electronics needs replaceme...

Страница 7: ...TS OF MEASUREMENT MAIN 1 4 2 6 Blue wire in back at pin 4 and bare copper wire on pin 5 of black drive motor switch START 1 4 2 8 Blue wire in back at pin 4 and bare copper wire on pin 3 of black drive motor switch If the resistance at the motor is correct there is an open circuit between the motor and machine control electronics Check for failed belt switch If the Start winding resistance is much...

Страница 8: ...ted go to step 7 If an open circuit is detected go to step 6 6 Visually check the wire connections to the heater If the connections look good replace the heater 7 Measure the resistance at the heater between the violet wire and the red wire terminals If an open circuit is not detected go to step 9 If an open circuit is detected go to step 8 8 Visually check the wire connections to the heater If th...

Страница 9: ...0 61 2 63 7 131 55 14 6 15 3 77 25 49 0 51 0 140 60 12 1 12 8 86 30 39 5 41 1 149 65 10 2 10 7 95 35 32 0 33 3 158 70 8 5 9 0 104 40 26 1 27 2 167 75 7 2 7 6 113 45 21 4 22 3 176 80 6 1 6 5 122 50 17 6 18 5 The table above shows the resistance values that should be observed for the various temperatures at the heater assembly If the thermistor resistance does not agree with the measurements in the ...

Страница 10: ...5 connector is inserted all the way into the machine control electronics If visual check passes replace the user interface assembly 2 Plug in dryer or reconnect power 3 Perform the Console Buttons and Indicators Diagnostic test page 1 to verify repair 4 If replacing the user interface assembly failed Unplug dryer or disconnect power Replace the machine control electronics Plug in dryer or reconnec...

Страница 11: ...the Machine Control Electronics 3 Remove the wire connections to the machine control assembly 4 Remove the one screw holding the machine control assembly to the metal bracket See figure 14 5 Push in on the tab located on the back of the machine control to slide it off the bracket Removing the User Interface Assembly 3 Remove the wire connections from the user interface assembly including the P5 ri...

Страница 12: ...n reconnecting wire connections be sure to route the user interface wires beneath the retainer clips on the user interface back cover REMOVING THE BACK PANEL 1 Unplug dryer or disconnect power 2 Remove the cover plate screw and cover plate See figure 17 3 Remove the nine rear screws from the back panel then remove panel Cover Plate Screw Cover Plate Figure 17 Remove screws Locking Tabs User Interf...

Отзывы: