2
Ϯ
Electric connection
Unscrew and remove the cover of the electrical panel of the condensing unit.
Connect each cable to its corresponding terminal according to its number.
Ground connection: loosen the ground screw on the electrical panel, then screw the ground cable.
Connect each cable in place using a spade terminal.
Replace the electrical panel cover in place.
Note: Do not invert the polarity, it could cause the appliance to malfunction. Check that the connections are firm and not making false
contact. If there is a connector, connect directly.
Wiring diagram
Make sure that the color of the outdoor unit's wires (evaporator unit) and the terminal number match those of the indoor unit
(condenser unit).
Terminal
Cover
Twisted wire
terminals
Solid wire
CAREGUIDE WHEN CONNECTING
ELECTRIC TERMINALS TO THE UNIT
1. When connecting the electrical terminals with a twisted cable,
make sure to use a spade terminal to connect the twisted
terminals to the electrical connections terminal of the
appliance.
Install the spade terminals in the connection cables and secure
them in its place.
2. When connecting the solid wire cable, make sure to connect it
with a hook shape and secure with the screw.
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Power connecting cord
Power connecting cord
Blue
Blue
Blue
Blue
Blue
Yellow/Green
Yellow/Green
Yellow/Green
Yellow/Green
Brown
Blue
Power connecting cord I
Brown
Brown
Brown
Brown
Brown
N
N
2L
N
N
2L
1L
1L
1L
1L
3L
3L
Terminal
Terminal
Terminal
Terminal
For above models, the power supply are connected from indoor unit.
For these models, the ground wire may be connected to the electric box directly.