TECH SHEET - DO NOT DISCARD
PAGE 4
FOR SERVICE TECHNICIAN’S USE ONLY
PART NO. 9762973 REV. A
DIAGNOSTICS SCREENS
1.
To enter into Diagnostics mode press the Cancel/OFF and START keys in the following order when the oven is not in cooking,
broiling, or cleaning mode.
Cancel/OFF > Cancel/OFF >START
The control will then indicate tESt in the display.
Press the TEMP arrow UP key to read the following:
1=Oven sensor temperature; 2=User cooking offset; 3=Software version; 4=Memory checksum; 5A=Last fault code;
5B=Cleared error code; 6=Accumulated operational time; 7=Switch state.
Screen 0: Diagnostics Mode
Screen 1: Oven Sensor Temperature
Screen 2: User Offset
Display depends on
software version.
Screen 3: Software Version
Display depends on
software version.
Screen 4: Memory Checksum
Screen 5B: Cleared Error Code
Screen 6: Accumulated Operational Time
Screen 5A: Last Fault Code
LOCK SWITCH
DOOR SWITCH
Screen 7: Switch State
0 = OPEN (UNLOCKED)
1 = CLOSED (LOCKED)