centerline

Panel C

7.

To wire through top,

mark a line 

7-1/2" from the right of the centerline on
the underside of the cabinet. Mark the
point on this line that is 2" from back wall.
Drill a 1-1/4" diameter hole through the
cabinet at this point. Note: If a cord-
connection kit is used, drill a 1-5/8"
diameter hole.

Numbers
correspond
to steps.

6.

Determine and clearly mark a

vertical centerline on the wall and cabinet
in the area the vent opening will be made.

3.

10.

4. 14.

5. 12. 13.

5. 12. 13.

7-1/2"

centerline

2"

from wall

(not cabinet

frame)

7-1/2"

centerline

centerline

3/4"

65-1/4" 

(to floor)

To wire through rear,

mark a line 7-1/2" from

the right of the centerline on the wall. Mark
the point on this line that is 65-1/4" from the
floor (or 3/4" from underside of cabinet).
Drill a 1-1/4" diameter hole through wall at
this point. 

To transition from a 3-1/4" x 10" rectangular
vent to a 7" round vent and vent through
the roof —

Start by making a 4" x 10-1/2" rectangle on
the underside of cabinet bottom:

a.

Mark lines 1-1/2" and 5-1/2" from the

back wall on the centerline of the
underside of cabinet. 

b.

Mark lines 5-1/4" to the right and left of

the centerline on the underside of
cabinet.

c.

Use saber and keyhole saws to cut a

rectangular opening for vent.

To make a 4" x 10-1/2" rectangle on the
underside of cabinet top and bottom:

a.

Mark lines 1-1/2" and 5-1/2" from the

back wall on the centerline of the
underside of cabinet. 

b.

Mark lines 5-1/4" to the right and left of

the centerline on the underside of
cabinet.

c.

Use saber and keyhole saws to cut a

rectangular opening for vent.

d.

Repeat steps 

a-c

for the underside of

the top of the cabinet.

If venting through the wall with 3-1/4" x 10"
rectangular vent —

To make a 4" x 10-1/2" rectangle in the wall:

a.

Measure from floor 65-7/8" and 62-3/8"

(or 1/8" and 3-5/8" down from underside
of cabinet) and mark on the centerline
on the back wall.

b.

Mark lines 5-1/4" to the right and left of

the centerline on the underside of
cabinet.

c.

Use saber and keyhole saws to cut a

rectangular opening for vent.

Now make a 7-1/8" x 7-5/8" slot on the
underside of the cabinet tops.

d.

Mark lines 5" and 5-1/2" from the back

wall on the centerline on the underside
of the top of cabinet. 

e.

Draw two 7-1/8" circles using the marks

made in step 

d

as center points.

f. 

Use saber and keyhole saws to cut a
slotted (oval) opening to make installing
7" round vent easier.

*

1-1/2"

5-1/4"

cabinet cutouts

5-1/4"

7-5/8"

*

5-1/2"

*

5"

from wall, not
cabinet frame

*

1-1/2"

*

from

wall not
cabinet
frame 

7-1/8"

R

*

1-1/2"

*

5-1/2"

from wall, not
cabinet frame

*

5-1/2"

5-1/4"

5-1/4"

cabinet
cutouts

8.

Содержание RH2300 SERIES

Страница 1: ...a this warranty does not apply Contact your authorized Whirlpool dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use Care Guide After checking Troubleshooting additional help can be found by checking the Assistance or Service section or by calling Whirlpool In the U S A call 1 800 253 1301 In Canada call 1 800 807 6777 8 05 ...

Страница 2: ...ses through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not ...

Страница 3: ...em 22 5 ft Maximum length 26 feet 1 90 elbow 5 ft 8 feet straight 8 ft 1 wall cap 0 ft Length of 3 1 4 x 10 system 13 ft Recommended standard fittings 6 ft 2 ft 3 1 4 x 10 90 elbow 5 ft 3 1 4 x 10 flat elbow 12 ft 3 1 4 x 10 wall cap 0 ft 3 1 4 x 10 to 7 4 5 ft 90 elbow 5 ft 45 elbow 2 5 ft 3 1 4 x 10 to 7 90 elbow 5 ft 7 wall cap 0 ft To install a vented only model installation Now start With ran...

Страница 4: ... and keyhole saws to cut a rectangular opening for vent To make a 4 x 10 1 2 rectangle on the underside of cabinet top and bottom a Mark lines 1 1 2 and 5 1 2 from the back wall on the centerline of the underside of cabinet b Mark lines 5 1 4 to the right and left of the centerline on the underside of cabinet c Use saber and keyhole saws to cut a rectangular opening for vent d Repeat steps a c for...

Страница 5: ...tem according to method needed See Venting requirements Use caulking to seal exterior wall or roof opening 10 If roof or wall cap does not have a damper attach rectangular damper supplied with hood to selected rectangular vent opening If damper is attached to back of range hood be sure damper hinge is toward the top If roof or wall cap does not have a damper and round vent is used install damper s...

Страница 6: ... to the green ground screw inside the range hood terminal box Use caulking to seal wire opening Replace terminal box cover white green ground screw ground wire black OPERATION OF RANGE HOOD CARE OF RANGE HOOD If you need FSP replacement parts FSP is a registered trademark of Whirlpool Corporation for quality parts Look for this symbol of quality whenever you need a replacement part for your WHIRLP...

Страница 7: ...de the United States or Canada 7 Pickup and delivery This major appliance is designed to be repaired in the home 8 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 9 Expenses for travel and transportation for product service in remote locations 10 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not ins...

Отзывы: