background image

Electrical Shock Hazard

Disconnect power before making
electrical connections.

Connect ground wire to green ground
screw in terminal box.

Failure to do so can result in death or
electrical shock.

WARNING

Panel D

centerline

keyhole slot

5a.

Lift range hood into final

position and center. Mark on underside of
cabinet the location for the four keyhole
mounting slots. Set range hood aside on a
protected surface.

To install a non-vented
(recirculating-only)
model:

3a.

Remove knockout from the

wiring opening (rear or top) to be used.
The range hood cabinet may have venting
knockouts. 

Do not remove these venting

knockouts.

The model 

cannot

be vented.

4a.

If your model does NOT have a

factory installed power cord, remove
terminal box cover on range hood.

6a.

Determine and clearly mark a

vertical centerline in the cabinet opening.

7a.

To wire through top,

mark a line 

7-1/2" from the right of the centerline on
the underside of the cabinet. Mark the
point on this line that is 2" from the back
wall. Drill a 1-1/4" diameter hole through
cabinet at this point. Note: If a cord-
connection kit is used, drill a 1-5/8"
diameter hole.

To wire through rear,

mark a line 7-1/2" from

the right of the centerline on the wall. Mark
the point on this line that is 65-1/4" from the
floor (or 3/4" from underside of cabinet).
Drill a 1-1/4" diameter hole through wall at
this point.

terminal
box
cover

7-1/2"

centerline

2" from
wall, (not
cabinet
frame)

front of hood

centerline

Excessive Weight Hazard

Use two or more people to move and
install range hood.

Failure to follow this instruction can
result in back or other injury.

WARNING

14.

For models requiring direct wiring:

Connect the white and black wires of the
power supply cable to the white and black
leads in the range hood with twist-on
connectors.
Connect the power supply ground wire to
the green ground screw inside the range
hood terminal box.
Use caulking to seal wire opening.
Replace terminal box cover

white

green ground
screw

ground
wire

black

13.

Lift range hood into final

position, feeding electrical wire through
wiring opening. Tighten mounting screws to
cabinet, making sure mounting screws are
in narrow neck of slots. .

keyhole slot

front of hood

Check that screw is in
narrow neck of slot.

screw

9.

Install vent through the vent

opening in upper cabinet or wall.
Complete venting system according to
method needed. See “Venting
requirements.” Use caulking to seal exterior
wall or roof opening.

10.

If roof or wall cap does not

have a damper, attach rectangular
damper supplied with hood 

to selected

rectangular vent opening. If damper is
attached to back of range hood, be sure
damper hinge is toward the top.

If roof or wall cap does not have a damper
and round vent is used,

install damper

(supplied with hood) in vent to prevent air
from flowing back into vent.

If roof or wall cap has a damper,

Do not

use damper blade supplied with range
hood.

11.

Do not turn on power until

installation is complete. 

Run wiring through

wall or cabinets according to the National
Electrical Code and local codes and
ordinances. Use caulking to seal ceiling or
outside wall opening.

12.

Start screws in the center of

the narrow neck of each of the four
keyhole mounting screw slots marked on
the cabinet bottom.

10a.

Lift range hood into final

position, feeding electrical wire through
wiring opening. Tighten mounting screws to
cabinet, making sure mounting screws are in
narrow neck of slots. 

keyhole slot

front of hood

Check that screw is in
narrow neck of slot.

screw

8a.

Do not turn on power until

installation is complete. 

Use caulking to seal

ceiling or outside wall opening. Run wiring
through wall or cabinets according to the
National Electrical Code and local codes
and ordinances. 

9a.

Start screws in the center of the

narrow neck of each of the four keyhole
mounting screw slots marked on the
cabinet bottom.

dampers

7-1/2"

centerline

3/4"

65-1/4" 

(to floor)

Electrical Shock Hazard

Plug into a grounded 3-prong outlet.

Do not remove ground prong.

Do not use an adapter.

Failure to follow these instructions can
result in death, fire, or electrical shock.

WARNING

For your personal safety, this range hood
must be grounded. To minimize possible
shock hazard, the cord must be plugged
into a mating, 3-prong, ground-type outlet,
grounded in accordance with National
Electrical Code, ANSI/NFPA 70 – latest
edition* and all local codes and
ordinances.
If mating outlet is not available, it is the
responsibility and obligation of the
customer to have a properly grounded, 3-
prong outlet installed by a qualified
electrician.
Do not use an extension cord.

Using a U.L.-listed power supply
cord-connection kit:

Follow Power Cord Kit instructions for
connecting wiring.

Replace terminal box cover.

For models with a factory

installed power cord:

Plug power cord into grounded 3-prong
outlet.

15.

Turn power supply on.

For cord connected models:

Содержание RH2300 SERIES

Страница 1: ...a this warranty does not apply Contact your authorized Whirlpool dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use Care Guide After checking Troubleshooting additional help can be found by checking the Assistance or Service section or by calling Whirlpool In the U S A call 1 800 253 1301 In Canada call 1 800 807 6777 8 05 ...

Страница 2: ...ses through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not ...

Страница 3: ...em 22 5 ft Maximum length 26 feet 1 90 elbow 5 ft 8 feet straight 8 ft 1 wall cap 0 ft Length of 3 1 4 x 10 system 13 ft Recommended standard fittings 6 ft 2 ft 3 1 4 x 10 90 elbow 5 ft 3 1 4 x 10 flat elbow 12 ft 3 1 4 x 10 wall cap 0 ft 3 1 4 x 10 to 7 4 5 ft 90 elbow 5 ft 45 elbow 2 5 ft 3 1 4 x 10 to 7 90 elbow 5 ft 7 wall cap 0 ft To install a vented only model installation Now start With ran...

Страница 4: ... and keyhole saws to cut a rectangular opening for vent To make a 4 x 10 1 2 rectangle on the underside of cabinet top and bottom a Mark lines 1 1 2 and 5 1 2 from the back wall on the centerline of the underside of cabinet b Mark lines 5 1 4 to the right and left of the centerline on the underside of cabinet c Use saber and keyhole saws to cut a rectangular opening for vent d Repeat steps a c for...

Страница 5: ...tem according to method needed See Venting requirements Use caulking to seal exterior wall or roof opening 10 If roof or wall cap does not have a damper attach rectangular damper supplied with hood to selected rectangular vent opening If damper is attached to back of range hood be sure damper hinge is toward the top If roof or wall cap does not have a damper and round vent is used install damper s...

Страница 6: ... to the green ground screw inside the range hood terminal box Use caulking to seal wire opening Replace terminal box cover white green ground screw ground wire black OPERATION OF RANGE HOOD CARE OF RANGE HOOD If you need FSP replacement parts FSP is a registered trademark of Whirlpool Corporation for quality parts Look for this symbol of quality whenever you need a replacement part for your WHIRLP...

Страница 7: ...de the United States or Canada 7 Pickup and delivery This major appliance is designed to be repaired in the home 8 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 9 Expenses for travel and transportation for product service in remote locations 10 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not ins...

Отзывы: