Vent system needed for installation is not
included. Backdraft damper supplied with
product must be used. If roof or wall cap
has a damper, do not use damper supplied
with hood. Use metal vent only. Rigid metal
vent is recommended.

Determine which outside venting method
you need to use. 

The length of the vent and number of
elbows should be kept to a minimum to
provide efficient performance. The size of
the vent should be uniform. Do Not install
two elbows together. Use duct tape to seal
all joints in the vent system. Vent can
terminate either through the roof or wall.
Use caulking to seal exterior wall or roof
opening around exhaust hood. For the
most efficient and quiet operation, it is
recommended that the range hood be
vented vertically through the roof using 7"
round vent.

Figures 1-4 show common venting methods
and what types of materials are needed.

Recommended vent length

Use 3-1/4" x 10" or 7" vent with a maximum
length of 26 feet for vent system. For best
performance, use no more than three 90°
elbows. To calculate the length of system
you need, add the equivalent feet for
each vent piece used in the system. See
the following examples.

Figure 1

Panel B

7" round
through roof

roof cap

66"

66"

3-1/4" x 10"
through the roof

roof cap

3-1/4" x 10"
damper

damper
located as far
from hood as
possible

Vertical roof venting

wall cap

66"

3-1/4" x 10"
through the wall

Vertical roof venting

Horizontal wall venting

roof cap

wall cap

elbows

3-1/4" x 10" to round
vent transition

7" min. diameter
round vent

Figure 4

Figure 3

4.

If your model does NOT have a

factory installed power cord, remove
terminal box cover from range hood. 

Figure 2

3-1/4" x 10" vent system

Recommended standard fittings

7" vent system

90° elbow

wall cap

3-1/4" x 10"
to 7"
transition

Maximum length 

= 26 feet

1 - transition 

=  4.5 ft.

2 - 90° elbows 

= 10  ft.

1 - wall cap 

=  0  ft.

8 feet straight 

=   8  ft.

Length of 7" system  = 22.5 ft.

Maximum length 

= 26 feet

1 - 90° elbow 

=   5  ft.

8 feet straight 

=   8  ft.

1 - wall cap 

=   0  ft.

Length of 3-1/4" x 
10" system 

=  13   ft.

Recommended standard fittings

6 ft.

2 ft.

3-1/4" x 10" 90°
elbow = 5 ft.

3-1/4" x 10" flat
elbow = 12 ft.

3-1/4" x 10" wall
cap = 0 ft.

3-1/4" x 10" to
7" = 4.5 ft.

90° elbow = 5 ft.

45° elbow = 2.5 ft.

3-1/4" x 10" to 7"
90° elbow = 5 ft.

7" wall cap = 0 ft.

To install a 
vented-only model
installation:

Now start...

With range hood in kitchen.

Slide cardboard or hardboard under range
before moving range across floor to
prevent damaging floor covering.

Cover countertop, cooktop or set-in range
with a thick, protective covering to prevent
damaging countertop.

wiring 
knockouts

rectangular vent
knockouts

1.

Disconnect and move freestanding

range from cabinet opening to provide
easier access to upper cabinet and rear
wall. Put a thick, protective covering over
cooktop, set-in range or countertop to
protect from damage or dirt.

2.

If your range hood is a vented-only

model, determine which venting method 
(roof or wall venting) you need to use. 

If your range hood is a non-vented-
(recirculating) only model, go to Step 3a,
Panel D.

3.

Remove knockout from the wiring

opening (top or rear) to be used.

For rectangular venting,

remove only the 

3-1/4" x 10" rectangular opening knockout
for the venting method (roof or wall) you
have selected.

terminal
box
cover

2 ft.

6 ft.

wall cap

3-1/4" x 10"
elbow

5.

Lift the range hood into final 

position and center. Mark on the underside
of cabinet the location of the four keyhole
mounting slots. Set range hood aside on a
protected surface.

Excessive Weight Hazard

Use two or more people to move and
install range hood.

Failure to follow this instruction can
result in back or other injury.

keyhole slot

front 
of hood

Venting requirements

Vented-only models 

Note: Non-vented (recirculating-only) models
cannot be converted to vent.

WARNING

Venting system must terminate to the
outside.

Do not terminate the vent in an attic or
other enclosed space.

Do not use four-inch laundry-type wall
caps.

Do not use plastic vent.

3-1/4" x 10"
to 7" fitting
required for
some models

Содержание RH2300 SERIES

Страница 1: ...a this warranty does not apply Contact your authorized Whirlpool dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use Care Guide After checking Troubleshooting additional help can be found by checking the Assistance or Service section or by calling Whirlpool In the U S A call 1 800 253 1301 In Canada call 1 800 807 6777 8 05 ...

Страница 2: ...ses through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not ...

Страница 3: ...em 22 5 ft Maximum length 26 feet 1 90 elbow 5 ft 8 feet straight 8 ft 1 wall cap 0 ft Length of 3 1 4 x 10 system 13 ft Recommended standard fittings 6 ft 2 ft 3 1 4 x 10 90 elbow 5 ft 3 1 4 x 10 flat elbow 12 ft 3 1 4 x 10 wall cap 0 ft 3 1 4 x 10 to 7 4 5 ft 90 elbow 5 ft 45 elbow 2 5 ft 3 1 4 x 10 to 7 90 elbow 5 ft 7 wall cap 0 ft To install a vented only model installation Now start With ran...

Страница 4: ... and keyhole saws to cut a rectangular opening for vent To make a 4 x 10 1 2 rectangle on the underside of cabinet top and bottom a Mark lines 1 1 2 and 5 1 2 from the back wall on the centerline of the underside of cabinet b Mark lines 5 1 4 to the right and left of the centerline on the underside of cabinet c Use saber and keyhole saws to cut a rectangular opening for vent d Repeat steps a c for...

Страница 5: ...tem according to method needed See Venting requirements Use caulking to seal exterior wall or roof opening 10 If roof or wall cap does not have a damper attach rectangular damper supplied with hood to selected rectangular vent opening If damper is attached to back of range hood be sure damper hinge is toward the top If roof or wall cap does not have a damper and round vent is used install damper s...

Страница 6: ... to the green ground screw inside the range hood terminal box Use caulking to seal wire opening Replace terminal box cover white green ground screw ground wire black OPERATION OF RANGE HOOD CARE OF RANGE HOOD If you need FSP replacement parts FSP is a registered trademark of Whirlpool Corporation for quality parts Look for this symbol of quality whenever you need a replacement part for your WHIRLP...

Страница 7: ...de the United States or Canada 7 Pickup and delivery This major appliance is designed to be repaired in the home 8 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 9 Expenses for travel and transportation for product service in remote locations 10 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not ins...

Отзывы: