background image

Register 

your

new device on

MyBosch now and

get free benefits:

bosch-home.com/

welcome

Ceiling-mounted ventilation

system

DRC96AQ50

[en]

User manual and assembly instruc-
tions

Содержание DRC96AQ50

Страница 1: ...Register your new device on MyBosch now and get free benefits bosch home com welcome Ceiling mounted ventilation system DRC96AQ50 en User manual and assembly instruc tions ...

Страница 2: ...e safety in structions The installer is responsible for en suring that the appliance works perfectly at its installation location Only use this appliance In accordance with these instructions for in stallation and use For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 2000 m above sea level Do not use the appliance With an ...

Страница 3: ...e Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a solid fuel heating appliance e g wood or coal burning unless the heating ap pliance has a sealed non removable cover There must be no flying sparks Hot oil or grease ignites very quickly Always supervise hot o...

Страница 4: ...the appliance should only be carried out by trained specialist staff Improper repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use genuine spare parts when re pairing the appliance If the power cord of this appliance is damaged it must be replaced by trained specialist staff An ingress of moisture can cause an elec tric shock Before cleanin...

Страница 5: ...ge amounts of steam select a higher fan speed in good time The odours are distributed around the room less Switch the appliance off when you are not using it The appliance does not consume any energy Switch off the lighting if you no longer require it The lighting does not consume any energy Clean or replace the filters at regular intervals The effectiveness of the appliance is increased Put the c...

Страница 6: ...ing air mode non regenerable fil ter press until LED 2 lights up in the LED display To set circulating air mode non regenerable fil ter press until LED 3 lights up in the LED display To convert the electronic control back to opera tion without the air recirculation filter press until LED 1 lights up on the LED display 2 To save the setting press and hold and for ap prox three seconds Or wait appro...

Страница 7: ...ing fumes De pending on the setting of the sensor sensitivity the op timum fan setting automatically switched on If the sensor control system reacts too weakly or too strongly the setting for the sensor sensitivity may change Default setting Fan setting 3 Lowest setting Fan setting 1 Highest setting Fan setting 5 Setting the sensor control Requirement The appliance is switched off 1 Press and hold...

Страница 8: ...Connecting appliances directly with each other Connecting appliances via the Wi Fi home network Note Please note the safety precautions in the instruc tion manual for your appliance and ensure that they are also observed when operating the appliance via the hob based hood control Tip Operating your appliance always takes priority It is not possible to use the hood controls on the hob dur ing this ...

Страница 9: ...onnection can be established the appliance automatically switches to the manual connection to the home network LED 2 and LED 7 flash in the LED display Log the appliance manually into the home network or press in order to restart the lo gin 5 On your mobile device follow the instructions for automatic network login a The login process is complete when LED 7 stops flashing and remains continuously ...

Страница 10: ...o use the Home Connect functions for the first time Note Please note that the Home Connect functions can only be utilised with the Home Connect app In formation on data protection can be retrieved in the Home Connect app Declaration of Conformity Robert Bosch Hausgeräte GmbH hereby declares that the appliance with Home Connect functionality meets the essential requirements and other relevant provi...

Страница 11: ...cleaner Cleaning glass 1 Observe the information regarding the cleaning agents Cleaning products Page 10 2 Clean with a soft cloth and glass cleaner Cleaning controls WARNING Risk of electric shock Penetrating moisture may cause an electric shock Do not use wet sponge cloths 1 Observe the information regarding the cleaning agents Cleaning products Page 10 2 Clean using a damp sponge cloth and hot ...

Страница 12: ...of grease removal WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly Requirement The grease filters have been removed 1 Observe the information regarding the cleaning agents Cleaning products Page 10 2 Soak the grease filter in hot soapy water Use special grease solvent for stubborn dirt You can obtain grease solvents from after sales servic...

Страница 13: ...Fault Cause troubleshooting The appliance is not working The mains plug of the power cord is not plugged in Connect the appliance to the power sup ply The circuit breaker is faulty Check the circuit breaker in the fuse box There has been a power cut Check whether the lighting in your kitchen or other appliances are working The lighting does not work Different causes are possible Call the after sal...

Страница 14: ...FD on the appliance s rating plate Depending on the model the rating plate can be found Inside the appliance remove grease filters for ac cess On top of the appliance Make a note of your appliance s details and the Cus tomer Service telephone number to find them again quickly Accessories Only use original accessories These have been made especially for your appliance Here you can find an overview ...

Страница 15: ...ctions when installing the ap pliance WARNING Risk of poisoning Risk of poisoning from flue gases being drawn back in Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and dis charge the exhaust gases into the open through an ex haust gas system e g a chimne...

Страница 16: ...ear protective gloves The appliance may fall down if it has not been prop erly fastened in place All fastening components must be fixed firmly and securely in place The appliance is heavy To move the appliance two people are required Use only suitable tools and equipment The appliance is heavy The appliance must not be fitted directly onto plasterboard or similar lightweight materials To ensure co...

Страница 17: ...f this is not possible an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of over voltage category III and according to the installa tion regulations The permanent electrical installation must only be wired by a professional electrician We recom mend installing a residual current circuit breaker RCCB in the appliance s power suppl...

Страница 18: ...The appliance is heavy To move the appliance two people are required Use only suitable tools and equipment 1 Insert the appliance into the cut out until you hear the mounting brackets engage 2 Carefully screw in diagonally opposite screws 5 Tighten the screws one at a time so that the appli ance is not wedged in the cut out 3 Note To ensure that the appliance is not damaged do not overtighten the ...

Страница 19: ...d remove the covers 5 Undo the opposite screws to loosen the fan box T 20 6 Push the fan box to the side and connect the appli ance to the power supply 7 Push the fan box to the other side and connect the pipework 8 Position the fan box in the centre and screw it firmly in place Installation variants of the fan box The fan box can be rotated according to the installation situation ...

Страница 20: ...h behind the metal hook and hook it in the cable guides 4 Store the remaining cable in the gap 5 Tighten the screw on the metal hook so that it is firmly in place Turning the air outlet clockwise 1 Ausgehend vom Auslieferungszustand den Lüfter kasten im Uhrzeigersinn drehen sodass der Luftauslass nach rechts zeigt 2 Undo the screw on the metal hook 20 3 Das Kabel durch den Metallhaken ziehen 4 Das...

Страница 21: ... the hinges Keep your hands away from the hinges 1 Open the hinges on the filter cover 25 2 Mount the filter cover on the designated screws and push it backwards forwards depending on the key hole opening into the narrow section 3 Tighten the fastening screws on the hinges 4 Check whether the appliance frame is lying flush Tighten the screws once again if necessary 5 Insert the grease filters To a...

Страница 22: ...supply 2 Remove the grease filters To avoid causing damage do not bend the grease filters 3 Open the cable duct on the filter cover and loosen the cable 4 Undo the screws on the hinges up to approx 7 mm Do not loosen the screws fully 5 Unhook and remove the filter cover 6 Undo the screws on the top frame assembly using a screwdriver and remove the top frame assembly 7 Loosen the screws on the side...

Страница 23: ...pe work 12 Push the fan box to the other side and pull out the mains plug 13 Rotate the fan box in such a way that the air outlet faces forwards 14 Remove the fan box 15 Loosen the mounting brackets on the appliance us ing a screwdriver 16 Slowly take the appliance out of the cutout ...

Страница 24: ...rvice Free and easy registration also on mobile phones www bosch home com welcome Looking for help You ll find it here Expert advice for your Bosch home appliances help with problems or a repair from Bosch experts Find out everything about the many ways Bosch can support you www bosch home com service Contact data of all countries are listed in the attached service directory Robert Bosch Hausgerät...

Отзывы: