3-13
f) Remove the three 1/2˝ hex nuts and
bracket washers.
d) Braze on an access valve and dis-
charge the sealed system refrigerant
into a refrigerant recovery bag.
e) Disconnect the high side line from the
compressor, and the suction line from
the accumulator.
High Side Line
To Compressor
g) Lift the compressor off the three rubber
shock mounts.
Rubber Shock
Mount
Suction Line
To Accumulator
1/2˝ Hex Nut
Bracket Washer
(1 of 3)