- 20 -
Test Mode D7-D15
D7 Filling valve
This function activates solenoid valve MV2.
You activate or deactivate the function by pressing the step key.
To pulse, press the alarm key. 0= OFF, 1= ON.
D8 Drain pump
This function activates motor M2.
You activate or deactivate the function by pressing the step key.
To pulse, press the alarm key. 0= OFF, 1= ON.
D9 Drain cooling
This function activates solenoid valve MV3.
You activate or deactivate the function by pressing the step key.
To pulse, press the alarm key. 0= OFF, 1= ON.
D10 Damper motor
This function activates motor M3.
In the display next to ”Time”, it is possible to read the status of the damper motor switch.
OFF= damper open, ON= damper closed.
You activate or deactivate the function by pressing the step key.
To pulse, press the alarm key. 0= OFF, 1= ON.
D11 Exhaust
This function activates the outlet for controlling the external ventilation, terminals 4 and 5.
In the display next to ”Time”, it is possible to read which outlet is active.
OFOF= both outlets are off, ONOF= outlet 4 is active and outlet 5 is off.
OFON= outlet 4 is off and outlet 5 is active. ONON= both outlets are active.
You activate or deactivate the function by pressing the step key.
0= OFOF, 1= OFON, 2= ONOF, 3= ONON.
D12 Cooling fan
This function activates motors M7 and M7A.
You activate or deactivate the function by pressing the step key.
To pulse, press the alarm key.
0= OFF, 1= ON.
D13 Buzzer
This function activates buzzer H2.
You activate and deactivate this function at high volume by pressing the step key.
It is possible to pulse at low volume by pressing the alarm key.
0= OFF, 1= ON.
D14 Interior light
This function activates interior light H1.
You activate or deactivate the function by pressing the step key.
To pulse, press the alarm key.
0= OFF, 1= ON.
D15 Oven temperature
Here it is possible to read the current oven temperature, P1.
In the field next to ”Temperature”, the current temperature is shown. If ERR appears, the
sensor circuit is defective.
In the field next to ”Time”, an adjustment value between 80 and 120 (default 100) is shown.
To adjust the temperature, press the time key until the digit in the display flashes. Then adjust
upwards or downwards until the correct temperature is shown. Finally, press the time key
again to save the setting.
The temperature can be adjusted by +- 10