WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati
Failure
desc
ription
/ repair
Trou
bles
ho
o
tin
g
Component
Fault
Description
Service Action
UI
41
Touch malfunction.
1)
Unplug the machine and wait 60’’; connect again
2)
Change the User Interface
IPC
47
IPC WIDE communication error
/ Time Out UI /TSM
1)
Verify connection of the product to the main;
2)
Verify connection between User Interface and
IPC;
3)
Change the User Interface
4)
Change the IPC
UI WIDE communication error
IPC WIDE communication error
/ live tag
IPC WIDE communication error
/ CRC Error
COOKTOP
58
EEPROM Configuration Error
1)
Verify connection of the coil NTC to the IPC, plug
the cooktop, execute manual configuration ;
2)
Change the IPC, execute manual configuration;
IPC
61
60730 Micro Register Error
1)
Switch off and on the cooktop
2)
Replace the IPC
60730 Micro RAM Error
60730 Micro FLASH Error
CH1 / CH2 Io Port Error
60730 Micro Program Flow
Error
60730 Micro Watchdog Error
BURNER
76
Coil 1/2 NTC Stuck
1)
Change the coil tray;
2)
Change the IPC;
Induc
tion
I
200