background image

2

Before you start...

Proper installation is your
responsibility. Make sure you have
everything necessary for correct
installation. It is the responsibility of
the installer to comply with the
clearances specified.

Check the location where the range
hood will be installed. The location
should be away from strong draft
areas, such as windows, doors, and
strong heating vents.

Mobile home installation

The installation of this range hood
must conform to the Manufactured
Home Construction Safety
Standards, Title 24 CFR, Part 328
(formerly the Federal Standard for
Mobile Home Construction and
Safety, Title 24, HUD, Part 280) or
when such standard is not
applicable, the Standard for
Manufactured Home Installation
1982 (Manufactured Home Sites,
Communities and Setups) ANSI
A225.1/NFPA 501A*, or latest edition,
or with local codes.

Important: Observe all governing
codes and ordinances.

This is the safety alert symbol.
This symbol alerts you to
potential hazards that can kill

or hurt you and others. All safety
messages will follow the safety alert
symbol and either the word “DANGER”
or “WARNING”. These words mean:

You can be killed or seriously injured
if you don’t follow instructions.

DANGER

WARNING

Your safety and the safety of

others is very important.

We have provided many important
safety messages in this manual and
on your appliance. Always read and
obey all safety messages.

All safety messages will tell you what
the potential hazard is, tell you how to
reduce the chance of injury, and tell
you what can happen if the
instructions are not followed.

You can be killed or seriously injured
if you don’t immediately follow
instructions.

Tools and
materials needed
for installation:

WARNING — TO REDUCE THE
RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO
PERSONS, OBSERVE THE
FOLLOWING:

Installation work and electrical
wiring must be done by qualified
person(s) in accordance with all
applicable Codes and Standards,
including Fire Rated
Construction.  Sufficient air is
needed for proper combustion
and exhausting of gases through
the flue (chimney) of fuel burning
equipment to prevent back
drafting. Follow the heating
equipment manufacturer’s
guideline and safety standards
such as those published by the
National Fire Protection
Association (NFPA), and the
American Society of Heating
Refrigeration and Air
Conditioning Engineers
(ASHRAE), and the local code
authorities.

When cutting or drilling into wall or
ceiling, do not damage electrical
wiring and other hidden utilities.

Ducted fans must always be
vented to the outdoors.

WARNING — To reduce the risk 
of fire, use only metal ductwork.

This unit must be grounded.

• compass or 8" (20.3 cm) circle template

• flat blade screwdriver

• Phillips screwdriver

• pliers

• metal snips

• drill

• 1-1/4" (3.0 cm) drill bit

• pencil

• ruler

• keyhole saw

• saber saw

• duct tape

• 7" (17.8 cm) round damper if using 

7" (17.8 cm) round vent system

Electrical
requirements

Important: Observe all governing
codes and ordinances.

It is the customer’s responsibility:

• To contact a qualified electrical

installer.

• To assure that the electrical 

installation is adequate and in 
conformance with National 
Electrical Code, ANSI/NFPA 70 
— latest edition*, or CSA
Standards C22.1-94, Canadian 
Electrical Code, Part 1 and 
C22.2 No.0-M91 - latest 
edition** and all local codes 
and ordinances.

A separate ground wire must be
used. It is recommended that a
qualified electrician determine that
the ground path is adequate.

A 120-volt, 60-Hz, AC-only, fused
electrical system is required. A
separate 15-amp circuit is
recommended.

Do not ground to a gas pipe.

Check with a qualified electrician if
you are not sure range hood is
properly grounded.

Do not have a fuse in the neutral or
ground circuit.

IMPORTANT:
Save Installation Instructions for
electrical inspector’s use.

The range hood must be connected
with copper wire only.

The range hood should be 
connected directly to the fused
disconnect (or circuit breaker) box
through flexible armored or
nonmetallic sheathed copper cable.
A U.L.- or C.S.A.-listed strain relief
must be provided at each end of the
power supply cable. Wire sizes
(COPPER WIRE ONLY) and
connections must conform with the
rating of the appliance as specified
on the model/serial rating plate.

Wire sizes must conform to the
requirements of the National
Electrical Code ANSI/NFPA 70 —
latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code
Part 1 and C22.2 No. 0-M91 - latest
edition** and all local codes and
ordinances.

This hood is factory set for vented
installations

. For non-vented

installations, purchase 30" 
(76.2 cm) Filter Kit No. 4396291 
or 36" (91.4 cm) Filter Kit No.
4396292 from your dealer.

Содержание GZ5730 Series

Страница 1: ...pector s use Part No 626890B 8284957 Rev A Pièce N 626890B 8284957 Rev A GZ5730 Series GZ5736 Series www whirlpool com Quick Reference Table of Contents Pages Before you start Electrical requirements Product dimensions Venting requirements Installation steps Use and Care Information Warranty Requesting Assistance or Service 2 2 3 3 4 7 7 8 8 9 10 30 76 2 cm and 36 91 4 cm Convertible Range Hood Ma...

Страница 2: ...the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork This unit must be gro...

Страница 3: ...e length of the vent system and number of elbows should be kept to a minimum to provide efficient performance The size of the vent system should be uniform Do Not install two elbows together Use duct tape to seal all joints in the vent system Vent system can terminate either through the roof or wall Use caulking to seal exterior wall or roof opening around exhaust hood For the most efficient and q...

Страница 4: ... 2 5 ft 0 8 m 3 1 4 x 10 8 3 x 25 4 cm to 7 17 8 cm 90 elbow 5 ft 1 5 m 7 17 8 cm wall cap 0 ft 0 m Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering Cover countertop cooktop or set in range with a thick protective covering to prevent damaging them 1 Disconnect and move freestanding range from cabinet opening to provide easier access to up...

Страница 5: ...1 cm 2 5 1 cm 1 1 4 3 2 cm dia hole 8 20 3 cm dia hole 7 17 8 cm round duct plate 6 Remove tape holding standard filters in place Remove both filters Insert flat blade screwdriver into slots in filters Push each filter toward back of hood lift out and set aside For non vented installations With the special blue and yellow strips facing towards the cooking surface attach the charcoal filters to the...

Страница 6: ...air tight 14 Connect the white and black wires of the power supply cable to the white and black leads in the hood with twist on connectors Connect the power supply ground wire to the green screw under the wiring cover Securely tighten the strain relief Using a U L listed power supply cord connection kit U S only Follow Power Cord Kit instructions for connecting wiring top back edge pivot up to 1 2...

Страница 7: ...For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flaming foods Clean ventil...

Страница 8: ...in water or put in dishwasher Special blue and yellow strips will blend to green when it is time to change the filter these strips work best when facing toward the cooking surface 30 76 2 cm Filter Kit No 4396291 or 36 91 4 cm Filter Kit No 4396292 is available from your dealer To clean hood turn off power supply remove filters Use a damp cloth and a mild detergent to wipe all grease laden surface...

Страница 9: ... area call our Customer Interaction Center telephone number your nearest authorized service center or Whirlpool Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to ask any questions or tell us about your concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone numb...

Страница 10: ...EBEC Montreal except South Shore 1 800 361 3032 South Shore Montreal 1 800 361 0950 Quebec City 1 800 463 1523 Sherbrooke 1 800 567 6966 ATLANTIC PROVINCES 1 800 565 1598 For further assistance If you need further assistance you can write to Inglis Limited with any questions or concerns at Consumer Relations Department Inglis Limited 1901 Minnesota Court Mississauga Ontario L5N 3A7 Please include ...

Страница 11: ...r local des installations électriques Pièce N 626890B 8284957A Part No 626890B 8284957A Série GZ5730 Série GZ5736 www whirlpool com Consultation rapide Table des matières Pages Avant de commencer Spécifications pour l installation électrique Dimensions du produit Circuit de décharge de l air Les étapes de l installation Utilisation et entretien Garantie Demande d assistance ou de service 2 3 3 3 4...

Страница 12: ...lateur doit toujours décharger l air à l extérieur AVERTISSEMENT Pour réduire le risque d incendie utiliser uniquement des conduits métalliques Cet appareil doit être relié à la terre compas ou gabarit circulaire de 20 3 cm 8 po tournevis à lame plate tournevis Phillips pince cisaille de ferblantier perceuse foret de 3 cm 1 1 4 po crayon règle scie à guichet scie sauteuse ruban adhésif pour condui...

Страница 13: ...igueur Le système doit décharger l air à l extérieur Ne pas terminer le conduit d évacuation au dessus d un plafond ou dans autre espace fermé Ne pas utiliser une bouche de décharge murale de 10 2 cm 4 po normalement utilisée pour un équipement de buanderie Ne pas utiliser des conduits de plastique Le système d évacuation nécessaire pour l installation n est pas inclus Déterminer la méthode approp...

Страница 14: ...e cuisson ou le plan de travail pour la protection contre les dommages et souillures 3 Percer quatre avant trous de 3 0 mm 1 8 po pour les vis de montage de la hotte Si le fond du placard forme une cavité ajouter une cale d appui de chaque côté 2 Déterminer quelle méthode de décharge de l air sera utilisée à travers le toit à travers le mur ou sans évacuation Lors de l expédition cette hotte est c...

Страница 15: ...x de ruban adhésif fixant les filtres standard en place Ôter les deux filtres insérer la lame plate d un tournevis dans les encoches des filtres pousser chaque filtre vers l arrière de la hotte et soulever pour enlever chaque filtre Installations sans circuit de décharge Fixer les filtres à charbon sur les filtres d aluminium rayures bleues et oranges orientées vers la table de cuisson encoches de...

Страница 16: ...le de cuisson pour protéger la hotte et la table de cuisson 15 Réinstaller le couvercle de la boîte de connexion 14 Raccorder les conducteurs du câble d alimentation de la hotte aux conducteurs de même couleur du arête d intersection sommet arrière pivot possibilité d ajustement latéral jusqu à 2 5 cm 1 po matériau de protection ensemble clapet raccord position d installation pour conduit de décha...

Страница 17: ...NIMISER LE RISQUE D UN FEU DE GRAISSE SUR LATABLE DE CUISSON Ne pas laisser une cuisson en cours à feu vif sans surveillance Un débordement peut provoquer la génération de fumée ou un feu de graisse Utiliser une puissance de chauffage moyenne ou basse pour faire chauffer de l huile lentement Faire toujours fonctionner le ventilateur de la hotte lors d une cuisson à feu vif ou pour flamber un mets ...

Страница 18: ... le nettoyage du ventilateur il ne faut pas déformer les pales ou perturber l alignement VEILLER À PROTÉGER LE MOTEUR CONTRETOUTE PROJECTION D EAU Vérifier que toutes les surfaces sont parfaitement sèches avant de réinstaller les filtres et de remettre l appareil sous tension Le moteur a fait l objet d une lubrification vie entière Ne pas huiler ou démonter le moteur WHIRLPOOL ET INGLIS LIMITÉE DÉ...

Страница 19: ...ez à notre Centre d interaction avec la clientèle votre Centre de service autorisé le plus proche ou le service de l usine Whirlpool en composant le 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez écrire en soumettant toute question ou problème au Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Veuillez indi...

Страница 20: ...ARIO QUÉBEC Montréal à l exception de la rive sud 1 800 361 3032 Rive Sud Montréal 1 800 361 0950 Québec 1 800 463 1523 Sherbrooke 1 800 567 6966 PROVINCES DE L ATLANTIQUE 1 800 565 1598 Pour plus d assistance Si vous avez besoin d autre d assistance vous pouvez écrire à Inglis Ltée en soumettant toute question ou préoccupation au Service des relatins avec la clientè le Inglis Ltée 1901 Minnesota ...

Отзывы: