18
3.
Rotate the rear feed cap
(Fig. 3-10a)
¼ turn clockwise
(Fig. 3-10b)
Fig. 3-10a
Fig. 3-10b
4.
The entire inner water tube assembly and the lower spray arm assembly can now be removed
from the dishwasher tub.
Removing the Water Inlet
The water inlet is located on the left side of the dishwasher tub.
(Fig. 3-11)
1.
From the inside of the tub, use a small pair of Channel Locks™ and turn the inlet grille ¼
turn counterclockwise and remove the grille.
(Fig. 3-12)
2.
The water inlet can now be separated from the dishwasher tub.
Fig. 3-11
Rear Feed Cap
Water Inlet
Servicing the Heating Element
The heating element
(Fig. 3-13)
should not be re-
moved unless it has failed. All critical components
of the dishwasher can be removed without remov-
ing the heating element.
If the heating element must be removed, it must
be replaced with a new one.
When installing a new heating element, follow the
Installation Instructions provided with the new item.
Fig. 3-13
Fig. 3-12
Water Inlet Grille
Water Inlet
Heating Element