19
Servicing the Overfill Assembly
Removing the Float
The float
(Fig. 3-14)
can be removed from inside
the tub.
1.
Tip the float slightly and gently toward the
back of the tub and lift up to disengage it
from the overfill assembly body.
Removing the Overfill Control Switch
The overfill control switch can be removed from
the overfill assembly without removing the assem-
bly from the tub.
1.
Remove the toe and access panels from
the bottom of the dishwasher.
2.
Unsnap the cover over the overfill con-
trol switch.
3.
Lift the overfill control switch from the as-
sembly.
4.
Disconnect the wiring harness connectors
from the switch terminals.
Removing the Overfill Assembly
1.
Remove the toe and access panels from
the bottom of the dishwasher.
2.
Remove the float.
3.
Remove the standpipe nut.
4.
Push the overfill assembly through the
bottom of the tub.
5.
Open the cover and lift the overfill control
switch from the assembly.
6.
Disconnect the wiring harness connectors
from the switch terminals.
Float
Standpipe
Nut
Overfill
Control
Switch
Overfill
Assembly
Fig. 3-14
Overfill
Switch
Cover
Tip Float Slightly
Toward Back to
Disengage It from
the Overfill
Assembly Body
Содержание GU1200XT
Страница 12: ...8 High Low High Low 130 F 54 C º º High Low Rinse High Low Purge Rinse ...
Страница 16: ...12 NOTES ...
Страница 39: ...35 Diagnostic Cycle Time Chart ...
Страница 43: ...39 STRIP CIRCUITS FILL WASH RINSE DRAIN DISPENSER VENT HEAT DRY ...
Страница 46: ...42 CO RPO RATIO N ...