14
Removing the Water Valve
1.
Disconnect the wiring harness connector
from the water valve solenoid terminals.
2.
Disconnect the water supply lines from the
inlet and outlet of the water valve.
3.
Remove the two (2) Hex-head screws
securing the water valve to the side of the
cabinet liner.
(Fig. 3-18)
NOTE:
Water may be present in these lines.
Have a small pail available to bleed
lines.
Fig. 3-18
Removing the Hot Gas Solenoid
The hot gas valve can be serviced with the unit tilted back in the service position.
1.
Disconnect the wiring harness plug from
the solenoid terminals.
2.
Remove the hex-head screw securing the
solenoid to the mounting bracket.
(Fig. 3-19)
Fig. 2-19
Screw
Solenoid
The water valve can be serviced with the unit in the installed position by removing the component
compartment cover.