12

Water System Piping

Piping Installation

Piping, fittings, and valves should be installed according to 
the installation drawing (Figure 13). If the indoor installation 
area is subject to freezing temperatures, the water piping 
must be protected by insulation.

Water supply pressure should not exceed 80% of the 
working pressure of the water heater. The working pressure 
is stated on the water heater’s data plate. If this occurs, 
a pressure limiting valve with a bypass may need to be 
installed in the cold water inlet line. This should be placed 
on the supply to the entire house in order to maintain equal 
hot and cold water pressures.

IMPORTANT: Heat cannot be applied to the water fittings 
on the heater as they may contain nonmetallic parts. If 
solder connections are used, solder the pipe to the adapter 
before attaching the adapter to the hot and cold water 
fittings.

IMPORTANT: Always use a good grade of joint compound 
and be certain that all fittings are drawn up tight.

1.  Install the water piping and fittings as shown in Figure 

13. Connect the cold water supply (3/4” NPT) to the 
fitting marked “C”. Connect the hot water supply (3/4” 
NPT) to the fitting marked “H”.

IMPORTANT:  Some models may contain energy saving 
heat traps to prevent the circulation of hot water within the 
pipes. Do not remove the inserts within the heat traps.

2.  The installation of unions in both the hot and cold water 

supply lines is recommended for ease of removing the 
water heater for service or replacement.

3.  The manufacturer of this water heater recommends 

installing a tempering valve or an anti-scald device 
in the domestic hot water line as shown in Figure 14. 
These valves reduce the point-of-use temperature of 
the water by mixing cold and hot water and are readily 
available for use. 

4.  If installing the water heater in a closed water system, 

install an expansion tank in the cold water line as 
specified under “Closed System/Thermal Expansion” 
(Page 13).

5.  Install a shut-off valve in the cold water inlet line. It 

should be located close to the water heater and be 
easily accessible. Know the location of this valve and 
how to shut off the water to the heater.

6.  A temperature and pressure relief valve must be 

installed in the opening marked “Temperature and 
Pressure (T & P) Relief Valve” on the water heater. 
A discharge line must be added to the opening of 
the T & P Relief Valve. Follow the instructions under 
“Temperature and Pressure Relief Valve,” page 13. 

7.  After piping has been properly connected to the water 

heater, remove the aerator at the nearest hot water 
faucet. Open the hot water faucet and allow the tank 
to completely fill with water. To purge the lines of 
any excess air, keep the hot water faucet open for 
3 minutes after a constant flow of water is obtained. 
Close the faucet and check all connections for leaks.

1” Minimum

Metal
Drain Pan
1 3/4” depth maximum

Drain

Drain line
3/4” ID
minimum

Discharge line
6” maximum
above drain

Temperature and
Pressure Relief Valve

In a closed system use a
thermal expansion tank

Cold Water

Supply to Fixtures

Cold Water

Inlet Valve

Pressure reducing

valve with bypass

Union

Hot Water
Outlet

Massachussetts:
Install a vacuum relief
in cold water line per
section 19 MGL 142.

Figure 13
Water Piping Installation

Main water supply

Figure 14
Typical Tempering
Valve Installation

Follow the tempering
valve manufacturer’s
instructions.

Cold

Water

Inlet

Hot

Water
Outlet

Tempered water
to fixtures

Tempering valve
(Set to 120°F)

Please note the following: 

• 

The system should be installed only with piping that is 
suitable for potable (drinkable) water such as copper, 
CPVC, or polybutylene. This water heater must not be 
installed using iron piping or PVC water piping.

• 

Use only pumps, valves, or fittings that are compatible 
with potable water.

• 

Use only full flow ball or gate valves. The use of valves 
that may cause excessive restriction to water flow is 
not recommended.  

• 

Use only 95/5 tin-antimony or other equivalent solder. 
Any lead based solder must not be used.

• 

Piping that has been treated with chromates, boiler 
seal, or other chemicals must not be used.

• 

Chemicals that may contaminate the potable water 
supply must not be added to the piping system.

Содержание energysmart Residential Electric Water Heater

Страница 1: ...amage personal injury or death INSTALLER AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO THE WATER HEATER OWNER RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE REFERENCE RETAIN THE ORIGINAL RECEIPT AS PROOF OF PURCHASE Table of Contents 2 6510374 W10100870 February 2006 Energy Smart Gas Water Heater with the Flame Lock Safety System To obtain technical warranty or service assistance during or after t...

Страница 2: ...if any part has been under water Immediately call a qualified service technician Water heaters subjected to flood conditions or any time the gas controls main burner or pilot have been submerged in water require replacement of the entire water heater Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen gas is extre...

Страница 3: ...the Flame Lock Safety System should only be performed by a qualified person Examples of a qualified person include licensed plumbers authorized gas company personnel and authorized service personnel IMPORTANT This water heater has a resettable thermal switch installed as part of the Flame Lock Safety System DO NOT attempt to disable or modify this feature in any way IMPORTANT The manufacturer and ...

Страница 4: ...y and call the fire department from a neighbor s home Do not attempt to clean the spill until all ignition sources have been extinguished Do not store combustible materials boxes magazines clothes etc on or in close proximity to the water heater Site Location Select a location near the center of the water piping system The water heater must be installed indoors and in a vertical position on a leve...

Страница 5: ...ble materials are stated on the data plate adjacent to the gas control valve thermostat of the water heater The water heater is certified for installation on a combustible floor IMPORTANT If installing over carpeting the carpeting must be protected by a metal or wood panel beneath the water heater The protective panel must extend beyond the full width and depth of the water heater by at least thre...

Страница 6: ... gas supply pressure must not exceed the maximum supply pressure as stated on the water heater s data plate The minimum supply pressure is for the purpose of input adjustment Gas Pressure Testing IMPORTANT This water heater and its gas connection must be leak tested before placing the appliance in operation If the code requires the gas lines to be tested at a pressure exceeding 14 W C the water he...

Страница 7: ...e is excluded from warranty coverage The following types of installation not limited to the following will require outdoor air for combustion due to chemical exposure and may reduce but not eliminate the presence of corrosive chemicals in the air beauty shops photo processing labs buildings with indoor pools water heaters installed in laundry hobby or craft rooms water heaters installed near chemi...

Страница 8: ...can be drawn from outside of the enclosure One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure as shown in Figure 4 The size of each opening free area is determined by the total BTUH input of all gas utilization equipment i e water heaters furnaces clothes dryers etc and the method by which the air is provided The BTUH input can be found on the ...

Страница 9: ...r supply openings consideration must be given to the blocking effect of protection louvers grilles and screens These devices can reduce airflow which in turn may require larger openings to achieve the required minimum free area Screens must not be smaller than 1 4 mesh If the free area through a particular design of louver or grille is known it should be used in calculating the specified free area...

Страница 10: ...ng water heater be sure to use the new drafthood supplied with the water heater Figure 9 Drafthood Installation Sheet Metal Screws four provided Drafthood Jacket top Install the drafthood with the four screws provided Legs Slots Slots Legs Vent Pipe Size It is important that you follow the guidelines in these instructions for sizing a vent pipe system If a transition to a larger vent size is requi...

Страница 11: ...erminate with a listed cap or other roof assembly and be installed according to their manufacturer s instructions Gas vents must be supported to prevent damage joint separation and maintain clearances to combustible materials Figures 11 and 12 IMPORTANT This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases An unused chimney flue or masonry enclosure m...

Страница 12: ...t line It should be located close to the water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater 6 A temperature and pressure relief valve must be installed in the opening marked Temperature and Pressure T P Relief Valve on the water heater A discharge line must be added to the opening of the T P Relief Valve Follow the instructions under T...

Страница 13: ... the requirements for Relief Valves and Automatic Shut off Devices for Hot Water Supply Systems ANSI Z21 22 The function of the temperature and pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater The valve s relief pressure must not exceed the working pressure of the water heater as stated on the data plat...

Страница 14: ... water outlet pipe Special Applications Combination Space Heating Potable Water System Some water heater models are equipped with inlet outlet tappings for use with space heating applications If this water heater is to be used to supply both space heating and domestic potable drinking water the instructions listed below must be followed The unit must be set to standard mode See Operating the Tempe...

Страница 15: ...s for possible gas leaks Correct any leak found Important Information About Your Water Heater This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident New technology used in meeting these standards makes this product less tolerant of installation errors or improper installation environments Please review the following info...

Страница 16: ...s completely filled with water before lighting the pilot Check the data plate near the gas control valve thermostat for the correct gas Do not use this water heater with any gas other than the one listed on the data plate If you have any questions or doubts consult your gas supplier or gas utility company Explosion Hazard Replace viewport if glass is missing or damaged Failure to do so can result ...

Страница 17: ...rson Figure 17 Match Relief Opening Drafthood Figure 18 Flame Characteristics Tips may have a yellow tint Yellow inner cones are satisfactory Correct flame soft blue Water Temperature Regulation The thermostat is adjusted to the pilot position when it is shipped from the factory Water temperature can be regulated by moving the temperature dial to the preferred setting The preferred starting point ...

Страница 18: ...Failure 6 Flashes Indicates Upper Sensor Failure 7 Flashes Indicates Electronic Control Failure 8 Flashes Indicates Valve Failure Continuous Solid Flash indicates system shutdown NOTE If the pilot lights but will only stay lit with the knob depressed in the pilot position look for the following status light codes 6 Second Solid Light followed by 4 Flashes The unit will not relight because it detec...

Страница 19: ...vice and Support Department for service information at 1 877 817 6750 3 Inspect your installation for any problems with venting or combustion air 4 Reset the thermal switch by depressing the small button in the center of the thermal switch A high temperature limit switch or ECO Energy Cut Off in the tank is used to shut off the unit if the water temperature exceeds 180 F 83 C The ECO is a single u...

Страница 20: ...supplies are not obstructed Build up of soot and carbon on the main burner and pilot burner Check for a soft blue flame Leaking or damaged water and gas piping Presence of flammable or corrosive materials in the installation area Presence of combustible materials near the water heater After servicing this water heater check to make sure it is working properly See Operating Your Water Heater sectio...

Страница 21: ...d manifold tube at the gas control valve thermostat Figures 22 23 6 Grasp the manifold tube and push down slightly to free the manifold tube pilot tube and thermopile 7 Carefully remove the manifold assembly from the combustion chamber NOTE Be sure not to damage internal parts Removing the Burner from the Manifold Assembly Natural Gas Burner Low Nox 1 Take off the burner by removing the two 2 scre...

Страница 22: ...Assembly Page 23 Figure 25 Two Piece Wire Connector Assembly Thermopile Connector Two Piece Wire Connector Pilot Tube Igniter Wire Retainer Clip Burner and other fittings not show for clarity Manifold Door Figure 26 Pilot Assembly Pilot Assembly Thermopile Connector Igniter Connector Thermal Switch Connectors Pilot Thermopile External Inspection Cleaning of the Flame trap Inspect the wrap around f...

Страница 23: ...re 28B 4 Inspect the door gasket and make sure there is no fiberglass insulation between the door gasket and the combustion chamber 5 Replace the two screws which secure the manifold assembly door to the combustion chamber Tighten securely There should be no space between the gasket part of the manifold door and combustion chamber IMPORTANT Do not operate the water heater if the door gasket does n...

Страница 24: ...ions Bubbles forming indicate a leak Correct any leak found If additional information is required contact the Service Department at 1 877 817 6750 TEFLON is a registered trademark of E I Du Pont De Nemours and Company 5 No leaks at pilot and manifold connection 6 Manifold door screws securely tightened 7 Depress the button on the thermal switch 1 Manifold door gasket properly sealed 2 Viewport not...

Страница 25: ...iping dip tube must be in cold inlet 8 Advise customer DRIP FROM RELIEF VALVE 1 Excessive water pressure 2 Heater stacking 3 Closed water system 1 Use a pressure reducing valve and relief valve 2 Lower the thermostat setting 3 See Closed System Thermal Expansion THERMOSTAT FAILS TO SHUT OFF 1 Thermostat not functioning properly 2 Improper calibration 1 Replace thermostat 2 Replace thermostat COMBU...

Страница 26: ...ng Refrigeration authorized service provider to correct the combustion air supply ventilation issue Correct size of openings to allow sufficient air NO YES YES YES NO Check the vent system for restrictions obstructions and check the vent termination height Refer to the Installation Instructions section of this manual for specific requirements NO Section C Pilot light will not remain lit Contact Cu...

Страница 27: ... PILOT ASSEMBLY KIT Natural Gas 13 BURNER Natural Gas Low Nox 14 MANIFOLD DOOR ASSEMBLY Natural Gas Low Nox 15 TWO PIECE WIRE CONNECTOR WITH RETAINER CLIP 16 MANIFOLD DOOR GASKET 17 VIEWPORT ASSEMBLY 18 THERMISTORS Pictured on next page When ordering repair parts always give the following information 1 Model serial and product number 2 Type of gas 3 Item number 4 Parts description Repair Parts Lis...

Страница 28: ...opile two piece wire connector with retainer clip thermal switch and pilot assembly Natural Gas Low Nox Item 15 Contains two piece wire connector and retainer clip Item 16 Contains manifold door gasket Item 17 Contains viewport Item 18 Contains replacement thermistors Item 18 WHIRLPOOL FLAME LOCK DESIGN and FLAME LOCK are trademarks of Whirlpool U S A 2006 Whirlpool Corporation All rights reserved...

Отзывы: