PAGE 12
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
TROUBLESHOOTING TESTS
IMPORTANT:
The following procedures
may require the use of needle probes
to measure voltage. Failure to use needle
probes will damage the connectors.
TEST #1: ACU Power Check
This test is used to determine if power is
present at the machine control electronics.
This test assumes that proper voltage is
present at the outlet.
1.
Unplug dryer or disconnect power.
2.
Check for appropriate line voltages at the
outlet: 240VAC (electric 2-phase), 208VAC
(electric 3-phase), or 120VAC (gas).
If line voltage is present, go to step 3.
If line voltage is not present, check for
tripped circuit breaker or blown household
fuse. If CB (circuit breaker) is not tripped,
have customer check with qualified
electrician.
3.
Remove console to access the machine
electronics.
4.
ACU VAC
– With voltmeter set to
AC
,
connect black probe to ACU P8-3 (N) and
red probe to P9-2 (L1). (See Figure 2.)
Plug in dryer or reconnect power.
If 120VAC is present, unplug dryer or
disconnect power and go to step 5.
If 120VAC is not present, unplug dryer or
disconnect power and perform TEST #2:
Supply Connections, page 13.
5.
ACU +5VDC
– With voltmeter set to
DC
,
unplug connector
P2
from the ACU and
connect black probe to ACU P2-3 (ground)
and red probe to P2-1 (+5V DC). Plug in
dryer or reconnect power.
If +5VDC is present, unplug dryer or
disconnect power and go to step 8.
If +5VDC is not present, go to step 6.
6.
Unplug dryer or disconnect power. Unplug
P14
from the ACU. Plug in dryer or reconnect
power and repeat step 5.
If +5VDC returns, one of the thermistors
has shorted. To diagnose thermistors,
see TEST #4a, page 18.
If +5VDC is not present, go to step 7.
7.
Unplug dryer or disconnect power.
Reconnect
P14
to the ACU and unplug
P2
from
the ACU. Plug in dryer or reconnect power and
repeat step 5. Perform voltage check inside
header P2 on ACU, between pins 1 & 3—DO
NOT SHORT PINS TOGETHER.
Figure 2 - ACU Connectors & Pinouts
8
3
P2 – WIDE TO UI (+5 VDC)
P2-1 BLK +5VDC
P2-2 BLU DATA
P2-3 YEL 5V GND
P8 – WATER VALVE/DOOR SWITCH
P8-5
OPEN
P8-4 TAN DOOR SWITCH
P8-3 WHT NEUTRAL
P8-2 G/Y CHASSIS GND
P8-1 RED WATER VALVE
(ON SOME MODELS)
P5 – +12VDC
P5-1
P5-2
P5-3 12V GND
P5-4
P5-5
P5-6
P5-7
P5-8 +12VDC
P9 – MOTOR/L1
P9-2 BLK L1
P9-1 LT BLU MOTOR
P13 – MOISTURE SENSOR
P13-2 RED MOISTURE SENSOR
P13-1 BLK MOISTURE SENSOR
P14 – THERMISTORS
P14-6 R/W OUTLET THERMISTOR
P14-5 BLK MODEL RTN (GAS MODEL)
P14-4 BLK MODEL (GAS MODEL)
P14-3 R/W OUTLET THERMISTOR
P14-2 RED INLET THERMISTOR
P14-1 RED INLET THERMISTOR
P13
P5-1
P2
P9
P14
P8
K3
K2
K1
Heater Relay #1
(Gas & Elect.)
L1 – BLK
Heater (E) – VLT
Heater (G) – RED
Heater Relay #2
(Elect. Only)
L1 – BLK
Heater – VLT
Motor Relay
•
= pin-1
P5-3
P5-8
Содержание Bravos XL
Страница 28: ...PAGE 28 FOR SERVICE TECHNICIAN S USE ONLY DO NOT REMOVE OR DESTROY Notes ...
Страница 58: ...POUR LE TECHNICIEN SEULEMENT PAGE 58 NE PAS ENLEVER NI DÉTRUIRE NOTES ...
Страница 59: ...PAGE 59 POUR LE TECHNICIEN SEULEMENT NE PAS ENLEVER NI DÉTRUIRE NOTES ...
Страница 60: ...POUR LE TECHNICIEN SEULEMENT PAGE 60 NE PAS ENLEVER NI DÉTRUIRE 04 15 NOTES ...