Whirlpool of India
260 L DC CFC FREE
This document is only intended for qualified technicians who are aware of the respective safety regulations.
First Released Date 17
TH
July, 2002
Subject to modification
Document No. WOI/DC/2002/07
PAGE 20 of 21
COMPONENTS
DIAGNOSING METHODS AND CRITERIA
Measuring
point
Normal
Abnormal
Compressor
Main winding to
common
14-16
0
Starting winding to
common
44-50
&
Red wire
connected to OLP
1 to 1.3 Amp
> 1.3 Amp
Normal
Abnormal
Relay
Relay in Mounting
position
Continuity between
Input terminal & RHS Pin No continuity
Relay in reverse
position
Continuity between
Input terminal & LHS Pin No continuity
Over Load
Normal
Abnormal
Protector
Continuity between
Supply terminal &
terminal to Compressor
No continuity
Position
Measuring point
Normal
Abnormal
Thermostat
ON
Between two
supply terminals
Continuity
No Continuity
OFF
Between two
supply terminals
No Continuity
Continuity
Position
Measuring point
Normal
Abnormal
Door Switch
Lever
Open
Between two
supply terminals
Continuity
No Continuity
Lever
pressed
Between two
supply terminals
No Continuity
Continuity
Signalization
Physical Check
Module
* Use the Multimeter to measure the
winding Resistance
- Bring the Compressor to cool down
completely before measuring
* Switch On the Compressor
?
?
* Use the Multimeter to check the
continuity
* Use the Multimeter to check the
continuity
* Use the Multimeter to check the
continuity
* Take out the capillary from Freezer
* Use the Multimeter to check the
continuity
* All components & wires are properly "Earthed"
* Green LED is "ON" when Compressor is "ON" & it's "OFF" when
Compressor is "OFF"
* Red LED is "ON" when Power is "ON" & it's "OFF" when
Power is "OFF"
* Both LEDs are straight & not bend
* Any component on PCB is burnt
* Black wire is connected to Common, Red wire is connected to Power &
Blue wire is connected to Compressor, as written on PCB
Compressor
?
?
* Switch on the Compressor
DIAGNOSING THE ELECTRICAL COMPONENTS