background image

Whirlpool of India

260 L DC CFC FREE

This document is only intended for qualified technicians who are aware of the respective safety regulations.
First Released Date 17

TH

 July, 2002

Subject to modification

Document No. WOI/DC/2002/07

PAGE 12 of 21

                                                                            

View – D

260 L EXPLODED VIEWS

Содержание 5040

Страница 1: ...PARTS SERVICEManual Model Code 5040 260L ELite NICKEL GREY Model Code 5130 260L Delux NICKEL GREY Phillippines ...

Страница 2: ...rst Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 2 of 21 CONTENTS 1 KEY FEATURES 2 2 WIRING DIAGRAM 3 3 REFRIGERANT FLOW DIAGRAM 4 4 R134 SERVICE CONSIDERATIONS 5 5 PART LIST 6 6 EXPLODED VIEWS 10 7 PARTS SPECIFIC TO 260 L 17 8 TROUBLE DIAGNOSIS CHART 18 9 COMPONENT CHECK GUIDE 20 10 GENERAL INSTRUCTIONS 21 ...

Страница 3: ...ect to modification Document No WOI DC 2002 07 PAGE 3 of 21 KEY FEATURES Improved Freezer latch for effective closing of the door White painted Roll Bond evaporator Single entry evaporator to increase the heat transfer between suction line capillary CFC Free Accommodate 2 ltr bottles in door C Evaporator Roll bond Suction line in Al capillary inside Refrigerant R134a QB51 GNF wrapper ...

Страница 4: ...CFC FREE This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 4 of 21 WIRING DIAGRAM ...

Страница 5: ...REE This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 5 of 21 REFRIGERANT FLOW DIAGRAM ...

Страница 6: ...ing equipment Old equipment hoses coupler valve seals and 0 rings are not compatible with R134a Oil in R134a compressors is very sensitive and capable of absorbing large quantities of moisture Moisture cannot be removed from the compressor oil in a service workshop Check service replacement compressor to make sure the PLUGS seals are in place and not tampered with Do not open compressor PLUGS for ...

Страница 7: ...DA20414800E CRISPER COVER PRINTED 1 1 B7 DA20415000E Humidity control Opera 1 1 B8 DA20415100E CRISPER SEPARATOR Y 1 B9 A2075503000 DOOR ASSY 260L DLX NICKEL GREY 1 C A2042003000 DOOR ASSY 250L ELITE NICKEL GREY 1 C DA20411700I DAIRY BIN GPPS OPERA ELITE 1 1 C1 DA20513300A LOCK ASSY OPERA 1 1 C10 DA205129300 SHIM FOR LOCK NICKEL GREY 1 1 C11 D114108000D LOCK RETAINER 1 1 C12 DA20412000E RIGHT DAIR...

Страница 8: ...VAPORATOR FRAME 260L ELITE 1 1 E1 A204158000D EVAPORATOR FRAME LH 260L ELITE 1 1 E2 A204048000E STAGGERED CONDENSER ASSY 260L OPERA 1 1 F1 DA20407700C Condenser Bracket OPERA 4 4 F2 A2045160000 PROTECTION BOX FOR LIGHT SWITCH 1 G10 DA20432600H Light Socket OPERA 170L 1 G10 DA20412900D EGG TRAY GPPS 1 2 G12 DA20446700D ICE TRAY ice magic 2 2 G2 DA20416500F DRIPTRAY DOOR PRINTED 1 1 G3 D116118000A L...

Страница 9: ...E This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 9 of 21 View A 260 L EXPLODED VIEWS ...

Страница 10: ...E This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 10 of 21 View B 260 L EXPLODED VIEWS ...

Страница 11: ...E This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 11 of 21 View C 260 L EXPLODED VIEWS ...

Страница 12: ...E This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 12 of 21 View D 260 L EXPLODED VIEWS ...

Страница 13: ...E This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 13 of 21 View E 260 L EXPLODED VIEWS ...

Страница 14: ...E This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 14 of 21 View F 260 L EXPLODED VIEWS ...

Страница 15: ...E This document is only intended for qualified technicians who are aware of the respective safety regulations First Released Date 17TH July 2002 Subject to modification Document No WOI DC 2002 07 PAGE 15 of 21 View G 260 L EXPLODED VIEWS ...

Страница 16: ...SLY PRINTED 1 D111308000K S T SCREW 6X13 1 A204058000E EVAPORATOR SUCTION LINE ASSY 260L EL 1 DA20410500D Retainer Thermo Bulb OPERA 1 DA20407500C Indicator Plug OPERA 1 D116433000D ANTI NOISE BUSH 2 A204208000C TRAY EVAP QB51 260L ELITE 1 DA20536200A INTERNAL LIGHT SWITCH OPERA 1 D1141040000 Screw for lock retainer Opera 2 DA20417200D Reflector OPERA 1 D111155700K S T SCREW 8 13 2 A207532000B PHI...

Страница 17: ...bject to modification Document No WOI DC 2002 07 PAGE 17 of 21 Component no Description Quantity Location A207505000B BASE PACKAGING 260L ELITE 1 Packing A2076310000 SLEEVE 4 FLAP 260L EL EXPORT 1 Packing A207510000A POLYTHENE BAG 260L ELITE 1 Packing A2075080000 CORNER POST FRONT 260l EL 2 packing A207507000A PAD TOP 260L EL 1 packing A2075090000 CORNER POST REAR 260L EL 2 packing ...

Страница 18: ... substances hamper cooling Flush the system and recharge and replace the drier No difference in temperature between suction pipe and discharge pipe The temperature of compressor is maintained at room temperature The Evap Does not cool down The compressor is defective Replace the compressor recharge the refrigerant and replace the drier Frost on the suction pipe The condenser is overheated The refr...

Страница 19: ...the Thermostat Ok No Replace Thermostat Is the door closed properly Frequent Defrosting Reqd No Check that the Door Gasket is properly sealed Check for the damaged Gasket Is too much food stored in the Freezer Compartment Partial Defrosting Yes Tightly cover stored things in Freezer Distribute stored things evenly in the Compartment Yes Yes Is the Thermostat capillary secure in Themobulb retainer ...

Страница 20: ...F Between two supply terminals No Continuity Continuity Position Measuring point Normal Abnormal Door Switch Lever Open Between two supply terminals Continuity No Continuity Lever pressed Between two supply terminals No Continuity Continuity Signalization Physical Check Module Use the Multimeter to measure the winding Resistance Bring the Compressor to cool down completely before measuring Switch ...

Страница 21: ...other Noisy Compressor Door opening noise door hinge to be oiled D Check for Electrical problems Defective power cord cabinet wiring Loose wire connector Loose defective Thermostat terminals Loose defective Relay OLP Open short jam Compressor A Check for proper Installation Check for proper leveling Front legs should be slightly higher than the rear legs To check leveling release the door from an ...

Отзывы: