TROUBLE CHECK FOR THE COOLING CYCLE
SYMPTON
CAUSE
SUGGESTIONS
?
The Evap. Cools down & warms again
?
The condenser warms in proportion as
the Evaporator cools
?
The process continues to repeat
Moisture in the refrigerant
causes the malfunction
Flush/vacuum the system and
recharge the refrigerant and replace
the drier
?
The condenser is cold
?
The evaporator is not cold
?
Compressor Temp. is high
?
Compessor current is higher than rated
Foreign substances hamper
cooling
Flush the system and recharge
and replace the drier
?
No difference in temperature between
suction pipe and discharge pipe
?
The temperature of compressor is
maintained at room temperature
?
The Evap. Does not cool down
The compressor is defective
Replace the compressor,
recharge the refrigerant and
replace the drier
?
Frost on the suction pipe
?
The condenser is overheated
?
The refrigerant in the evaporator is not
efficient
?
Compressor current is higher than
rated
Too much refrigerant
Recharge the refrigerant and
replace drier
?
The compressor surface temperature is
high
?
The condenser is cold
?
The refrigerator is not easily getting
cooled
?
Compressor current is lower than rated
Refrigerant leak (slight
refrigerant leakage causes
partial cooling with frost on
Evap.)/Less charge
After repairing the leaked
spot (if any), recharge the
refrigerant and replace drier