Important: Observe all governing codes
and ordinances.

Exhaust your dryer to the outside.

Moisture and lint indoors may cause:
• Lint to gather around the dryer where

it can be fuel for a fire.

• Moisture damage to woodwork,

furniture, paint, wallpaper, carpet,
etc.

• Housecleaning problems and health

problems.

If the washer/dryer is installed in a
confined area such as a bedroom,
bathroom or closet, it must be
exhausted to the outside

and provision

must be made for enough air for
ventilation. Check governing codes and
ordinances. Also refer to the “Recessed
and closet installation instructions” on
Panel G.

Dura Safe

TM

vent products are

recommended and are available from
your dealer. See Panel G.
Four-inch diameter vent is required.
Use a heavy metal vent. 

Do not use plastic or

metal foil vent.
•  Do Not use non-metal flexible vent, or

exhaust hoods with magnetic latches.

•  Do Not exhaust dryer into a chimney,

furnace, cold air vent, attic or crawl space,
or any other vent used for venting.

•  Do Not install flexible vent in enclosed walls,

ceilings or floors.

Rigid metal vent is recommended

to prevent

crushing and kinking.

Flexible metal vent 

must be fully extended

and supported when the dryer is in its final
position.
Remove excess flexible vent to avoid
sagging and kinking that may result in
reduced air flow.

An exhaust hood 

should cap the exhaust

vent to prevent rodents and insects from
entering the home.

Exhaust outlet hood

must be at least 12

inches from the ground or any object that
maybe in the path of the exhaust (such as
flowers, rocks or bushes, etc.).

If using an existing exhaust system, clean lint
from entire length of system and make sure
exhaust hood is not plugged with lint.

Panel B

G.

If the washer/dryer is installed in a

confined area such as a bedroom,
bathroom or closet, it must be
exhausted to the outside and provision
made for enough combustion air and
ventilation air. (Check governing codes
and ordinances. Also refer to the
section in this instruction covering
Recessed and closet installations.)

gas
supply
line

H.

This washer/dryer is equipped

with its own permanent, flexible gas
connector, design-certified by CSA
International, for connecting the
appliance to the gas supply line.

I.

If rigid pipe is

used as a gas
supply line, a
combination of
pipe fittings must
be used to
obtain an in-line
connection to
the washer/dryer.

J.

Make sure the back and sides of

the cabinet are free of obstructions to
permit adequate clearance of air
openings for combustion air. (See
“Recessed and closet installation
instructions” for minimum spacing
requirements, Panel G.)

household rigid
gas supply pipe

K.

For ease of installation, operating

and servicing (if ever needed),
adequate space should be provided
around the washer/dryer.

L.

An 1/8-inch NPT plugged tapping,

accessible for test gauge connection,
must be installed immediately upstream
of the gas supply connector to the
dryer.
The dryer and its individual shutoff valve
must be disconnected from the gas
supply piping system during any
pressure testing of that system at test
pressures in excess of 1/2 psig (3.45 kPa).
The dryer must be isolated from the gas
supply piping system by closing its
individual manual shutoff valve during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psig (3.45 kPa).

Electrical requirements

A three-wire, single-phase, 120-volt, 
60-Hz, AC-only, 15- or 20-ampere, fused,
electrical supply is required. A time-
delay fuse or circuit breaker is
recommended. If your home has a
circuit wired and fused for 20 amperes,
this is preferred. If you are installing a
new circuit, one wired and fused for 
20 amperes is recommended. It is also
recommended that a separate circuit
serving only this appliance be provided.

Recommended

ground method

For your personal safety, this appliance
must be grounded. This washer/dryer is
equipped with a power supply cord
having a 3-prong ground plug. To
minimize possible shock hazard, the
cord must be plugged into a mating, 
3-prong, ground-type outlet, grounded
in accordance with the National
Electrical Code, ANSI/NFPA 
70 — latest edition,** and all local codes
and ordinances. (See Figure 1.) If a
mating outlet is not available, it is the
personal responsibility and obligation of
the customer to have a properly
grounded, 3-prong outlet installed by a
qualified electrician.

3-prong
ground
plug

power
supply
cord

Figure 1

ground
prong

3-prong
ground-type
outlet

Exhaust requirements

A.

This installation must conform with

American National Standard, National
Fuel Gas Code ANSI Z223.1 — latest
edition,* and all local codes and
ordinances.

B.

The design of this dryer has been

certified by CSA International for use at
altitudes up to 10,000 feet above sea
level at the B.T.U. rating indicated on
the model/serial plate. Burner input
adjustments are not required when the
dryer is operated up to this elevation.
When installed above 10,000 feet, a four

C.

Check that this

dryer is equipped with
the correct burner for
the particular type of
gas in the home.
Burner information will
be found on the rating plate in the door
well of the appliance. If this information
does not agree with the type of gas
available, see your dealer.

D.

This dryer is equipped for use with

NATURAL GAS. It is certified by CSA
International for manufactured, mixed
and L.P. (propane or butane) gases with
appropriate conversion. No attempt
shall be made to convert the appliance
from the gas specified on the
model/serial rating plate for use with a
different gas without consulting the
service gas supplier or a Whirlpool-
designated service company.

Conversion must be done by a qualified
service technician. Gas conversion kit
part numbers are listed on the burner
bracket behind the access panel. 
(See Panel E.)

E.

Provide a 

rigid gas supply

line to

the dryer location. When rigid pipe is
used, it should be 1/2-inch IPS. Pipe-joint
compounds resistant to the action of
L.P. gas must be used.

to
dryer

shutoff valve
“open” position

F.

The supply line shall be equipped

with a shutoff valve. This valve should be
located in the same room as the
washer/dryer and should be in a
location that allows ease of opening
and closing. Do Not block access to the
shutoff valve.

Important: Observe all governing codes
and ordinances.

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

WARNING

Electrical Shock Hazard

Plug into a grounded 3-prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can
result in death, fire, or electrical shock.

Fire Hazard

Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions 
can result in death or fire.

percent (4%) reduction of the burner
B.T.U. rating shown on the model/serial
plate is required for each 1,000 foot
increase in elevation. For assistance
when converting to other gas types
and/or installing above 10,000 feet
elevation, contact your local service
company.

WARNING

Copies of the standards listed may be obtained from:

*CSA International

8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

** National Fire Protection Association

Batterymarch Park
Quincy, Massachusetts 02269

Use pipe-joint
compound.

Adapter
supplied

Do Not use
pipe-joint
compound.

flexible gas
connector

Содержание 3395326

Страница 1: ... Large Capacity Thin Twin IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use IMPORTANT Read and save these instructions Home Appliances www whirlpool com ...

Страница 2: ...ched to a wall The cable bracket must be secured to a wall stud within a 27 inch wide area that is 28 inches minimum to 41 inches maximum from floor See Panel F 1 8 inch NPT plugged tapping is required See Panel B Step L Do Not store or operate washer dryer below 32 F some water may remain in washer Proper operation of dryer cycles requires temperatures above 45 F See Use Care Guide for Winterizin...

Страница 3: ...installing a new circuit one wired and fused for 20 amperes is recommended It is also recommended that a separate circuit serving only this appliance be provided Recommended ground method For your personal safety this appliance must be grounded This washer dryer is equipped with a power supply cord having a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a matin...

Страница 4: ... with your washer dryer Replace inlet hoses after 5 years of use to reduce the risk of hose failure Inspect and replace inlet hoses if bulges kinks cuts wear or leaks are found When replacing your inlet hoses mark the date of replacement on the label with a permanent marker Pull the shipping strap completely out of the washer Excessive Weight Hazard Use two or more people to move and install washe...

Страница 5: ...her dryer to its permanent location Remove cardboard from under washer dryer 14 Cut the plastic strap securing the cable wire bracket to the power supply cord and discard DO NOT CUT CABLE Remove the power supply cord from the bracket Attach the cable wire bracket to the wall Check that bracket is secure See Panel F 15 Tilt washer dryer forward raising back legs 1 inch off of floor to adjust rear s...

Страница 6: ...ns again 24 Connect exhaust vent to washer dryer and then to the exhaust hood Use the straightest path possible to avoid 90 turns Use clamp to seal all joints in the exhaust system Use caulking compound to seal exterior wall opening around exhaust hood 25 CHECK ELECTRICAL REQUIREMENTS BE SURE YOU HAVE CORRECT ELECTRICAL SUPPLY AND RECOMMENDED GROUND METHOD Check the Installation Instructions to se...

Страница 7: ...or standpipe 7 Gas shutoff valve is open in supply line If you need assistance The Whirlpool Customer Interaction Center will answer any questions about operating or maintaining your washer dryer not covered in the Installation Instructions The Whirlpool Customer Interaction Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the washer...

Страница 8: ...ion must be exhausted outdoors closet door 48 sq in 24 sq in 1 min 3 3 48 sq in front view side view closet door 24 sq in WARNING To reduce the risk of fire this appliance MUST BE EXHAUSTED OUTDOORS SURE CONNECTTM Vent Kit CRUSH RESISTANT Dura SafeTM Kits Make Installation Easy Provides 4 1 2 clearance between dryer and wall Snap Lock fittings Total kit length 8 feet Additional vent can be snapped...

Страница 9: ...9022 Part No 3395326 Rev F 2000 Whirlpool Corporation Registered Trademark of Whirlpool U S A Printed in U S A Twin with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use www whirlpool com ...

Отзывы: