background image

Panel G

Recessed and closet

installation instructions

This washer/dryer may be installed in a
recessed area or closet.

The installation spacing is in inches and
is minimum allowable. Additional
spacing should be considered for ease
of installation, servicing and compliance
with local codes and ordinances.
If closet door is installed, the minimum
unobstructed air openings in top and
bottom are required. Louvered doors
with equivalent air openings are
acceptable.

Note: No other fuel-burning appliance
may be installed in the same closet.

Other installations must use the minimum
dimensions indicated.

Product dimensions

Dryer

Washer

0" 

*

0" 

*

Front View

6"

Recessed area minimum installation spacing

28"

48"

72-3/4"

5"

33-

1/4"

26-1/4"

32-1/4"

0" ***

Side View

27-3/8" 

1-1/2"
hot
water
inlet

13-1/2"
recess
width

5"
recess
depth

28-1/2"
Drain

Exhaust
outlet
36-3/4"

27"
cold
water
inlet

34-3/4"

22-3/4"

Most installations will require at least 5 inch
clearance behind the dryer for the dryer
vent.

Location must be large enough to fully
open dryer door.

* Additional clearances for wall, door and floor moldings may be required or if external exhaust

elbow is used.

** Opening is minimum for closet door. Louvered door with equivalent air openings is acceptable.

*** Additional space may be needed for exhaust elbow.

6" 

0" ***

Closet installation must be exhausted outdoors.

closet door

48 sq. in. **

24 sq. in. **

1" min.

3"

3"

48 sq. in. **

front view

side view

closet door

24 sq. in. **

WARNING - To reduce the risk of fire, this appliance MUST BE EXHAUSTED OUTDOORS.

SURE CONNECT

TM

Vent Kit

CRUSH

RESIST

ANT

Dura Safe

TM 

Kits Make Installation Easy

Provides 4 1/2” 
clearance between 
dryer and wall

Snap-Lock fittings

Total kit length 
8 feet

Additional vent can 
be snapped between
sections for 
longer runs

Kit Contains:

2- 4' vent sections with attached close elbows
1- Wall plate for close clearance installations
2- 4" clamps

Part #4396028

Sections separate, 
fittings can face
same or opposite

Extra long
band-clamp 
for dryer 
connection

Swivel collar

Beveled edges
allow corner
installations

Telescoping 
sections

Swivel collar 
wall connection

Provides 2 1/2” clearance 
between dryer and wall

Great for closet

installations

0"-18", 18”-29” or 
29”- 50” periscopes 
include one male 
snap-lock fitting, 
one extra long 
draw-band collar 
and one clamp

2

 1/2"

1

/

2

"

Periscopes For Offset

Outlets, Tight Installations

Use when vent outlets
overlap or are offset

Excess length can 
be trimmed to fit

18"-29" and 29"-50" Periscope

0"-18" Periscope

0"-18" : Part #4396037

18"-29" : Part #4396011
29"-50" : Part #4396014

Part #4396037

18"-29" : Part #4396011             29"-50" : Part #4396014

Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.

For more information, 

or to easily place your

order, call 

1-800-442-9991

To have your venting 

professionally installed,

call 

1-800-253-1301

for the nearest 

authorized service

provider.

.

Содержание 3395326

Страница 1: ... Large Capacity Thin Twin IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use IMPORTANT Read and save these instructions Home Appliances www whirlpool com ...

Страница 2: ...ched to a wall The cable bracket must be secured to a wall stud within a 27 inch wide area that is 28 inches minimum to 41 inches maximum from floor See Panel F 1 8 inch NPT plugged tapping is required See Panel B Step L Do Not store or operate washer dryer below 32 F some water may remain in washer Proper operation of dryer cycles requires temperatures above 45 F See Use Care Guide for Winterizin...

Страница 3: ...installing a new circuit one wired and fused for 20 amperes is recommended It is also recommended that a separate circuit serving only this appliance be provided Recommended ground method For your personal safety this appliance must be grounded This washer dryer is equipped with a power supply cord having a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a matin...

Страница 4: ... with your washer dryer Replace inlet hoses after 5 years of use to reduce the risk of hose failure Inspect and replace inlet hoses if bulges kinks cuts wear or leaks are found When replacing your inlet hoses mark the date of replacement on the label with a permanent marker Pull the shipping strap completely out of the washer Excessive Weight Hazard Use two or more people to move and install washe...

Страница 5: ...her dryer to its permanent location Remove cardboard from under washer dryer 14 Cut the plastic strap securing the cable wire bracket to the power supply cord and discard DO NOT CUT CABLE Remove the power supply cord from the bracket Attach the cable wire bracket to the wall Check that bracket is secure See Panel F 15 Tilt washer dryer forward raising back legs 1 inch off of floor to adjust rear s...

Страница 6: ...ns again 24 Connect exhaust vent to washer dryer and then to the exhaust hood Use the straightest path possible to avoid 90 turns Use clamp to seal all joints in the exhaust system Use caulking compound to seal exterior wall opening around exhaust hood 25 CHECK ELECTRICAL REQUIREMENTS BE SURE YOU HAVE CORRECT ELECTRICAL SUPPLY AND RECOMMENDED GROUND METHOD Check the Installation Instructions to se...

Страница 7: ...or standpipe 7 Gas shutoff valve is open in supply line If you need assistance The Whirlpool Customer Interaction Center will answer any questions about operating or maintaining your washer dryer not covered in the Installation Instructions The Whirlpool Customer Interaction Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the washer...

Страница 8: ...ion must be exhausted outdoors closet door 48 sq in 24 sq in 1 min 3 3 48 sq in front view side view closet door 24 sq in WARNING To reduce the risk of fire this appliance MUST BE EXHAUSTED OUTDOORS SURE CONNECTTM Vent Kit CRUSH RESISTANT Dura SafeTM Kits Make Installation Easy Provides 4 1 2 clearance between dryer and wall Snap Lock fittings Total kit length 8 feet Additional vent can be snapped...

Страница 9: ...9022 Part No 3395326 Rev F 2000 Whirlpool Corporation Registered Trademark of Whirlpool U S A Printed in U S A Twin with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use www whirlpool com ...

Отзывы: