OPERATING YOUR WATER HEATER

Before Using

1.  Make sure the water heater has been properly    

installed. See “Installing Your Water Heater”  section.

2.  Completely fill the tank with water. (See Figure 2) 

3.  After the water heater tank is completely filled with 

water, connect electrical power to the water heater.

4.  Read the “Water Temperature Regulation” section of 

this manual. 

If the instructions are not clear, contact a 

qualifi ed person.

 

5.  Adjust the thermostat to the desired temperature

setting as described under “Adjusting the Thermostat/  
High Limit Control” section.

IMPORTANT: Do not attempt to operate this water heater 
if the thermostat(s), or surrounding insulation has been 
exposed to water in any way. Immediately call a qualifi ed 
person to inspect the water heater and replace any 
thermostat or insulation that has been exposed to water. 
Do not attempt to repair these parts. Water heaters 
subjected to fl ood conditions or any time the thermostat(s) 
have been submerged in water require replacement of the 
entire water heater.

Safety Shut-off

This water heater is designed to automatically shut-off 
in the event that the water temperature exceeds 170°F 
or 77°C. A high limit control switch is used to shut off the 
power to the elements if the water temperature exceeds 
170°F or 77°C. The  high limit control switch can be 
reset by fi rmly pushing in the red reset button located on 
the thermostat. Follow the instructions under “Adjusting 
the Thermostat/High Limit Control”, section to properly 
reset the high limit control. If the high limit control switch 
continues to shut-off the water heater contact a qualifi ed 
person for service.

Water Temperature Regulation

Water temperature over 125°F can cause 
severe burns instantly or death from scalds.

Children, disabled and elderly are at highest 
risk of being scalded.

Feel water before bathing or showering.

Temperature limiting valves are available.

WARNING

The thermostat is adjusted to a temperature setting 
of 120°F or lower when it is shipped from the factory. 
Water temperature can be regulated by adjusting the 
thermostat to the preferred setting as shown in “Adjusting 
the Thermostat/High Limit Control.” The preferred starting 
point is 120°F. There is a hot water scald potential if the 
thermostat is set too high. 
IMPORTANT:

  

Adjusting the thermostat past 120°F on the 

thermostat will increase the risk of scald injury in the times 
shown below.  

Water 

Temperature °F

Time for 1st 

Degree Burn 

(Less Severe Burns)

Time for 

Permanent Burns 

2nd & 3rd Degree 
(Most Severe Burns)

110
116
116

122
131
140
149
154

(normal shower temp.)

(pain threshold)

35 minutes

1 minute

5 seconds
2 seconds

1 second

instantaneous

45 minutes

5 minutes

25 seconds

5 seconds
2 seconds
1 seconds

(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)

NOTE: During low demand periods when hot water is not 
being used, a lower thermostat setting will reduce energy 
losses and may satisfy your normal hot water needs. If hot 
water use is expected to be more than normal, a higher 
thermostat setting may be required to meet the increased 
demand. 
When leaving your home for extended periods (vacations, 
etc.) turn the thermostat to its lowest setting. This will 
maintain the water at low temperatures with minimum 
energy losses and prevent the tank from freezing during 
cold weather. 

Содержание 121802

Страница 1: ... 4 Date of installation 5 Place of Purchase Water Heater Safety 2 Installing Your Water Heater 3 8 Unpacking Instructions 3 Location Requirements 4 Electrical Requirements 5 Water System Piping 6 Installation Checklist 8 Operating Your Water Heater 9 11 Water Temperature Regulation 9 Adjusting the Thermostat High Limit Control 10 Operational Conditions 11 Maintenance of Your Water Heater 12 13 Tro...

Страница 2: ...s not been used for a long period of time 2 weeks or more Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system When hydrogen is present there will probably be an unusual sound such as air escaping thr...

Страница 3: ...is manual If you lack the necessary skills required to properly install this water heater or you have difficulty following the directions you should not proceed but have a qualified person perform the installation of this water heater Examples of a qualified person include licensed plumbers authorized gas company personnel and authorized service personnel Massachusetts code requires this water heate...

Страница 4: ...any external plumbing leak including those from improper installation may cause early failure of the tank due to corrosion if not repaired If the owner operator is uncomfortable with making the repair a qualified person should be contacted A suitable metal drain pan should be installed under the water heater as shown below to help protect the property from damage which may occur from condensate fo...

Страница 5: ...the electrical supply to the water heater A standard 1 2 inch opening has been made in the junction box for conduit connections 5 Connect ground wire to green ground screw in the junction box of the water heater Reinstall the junction box cover Figure 3 120 240V 2 Wire Models Junction Box Cover Ground Wire Conduit White Wire 120V Models Red Wire 240V Models Black Wire Green Ground Screw Black Whit...

Страница 6: ...nt of use temperature of the hot water by mixing cold and hot water and are readily available Contact a licensed plumber or the local plumbing authority for more information 4 If installing the water heater in a closed water system install an expansion tank in the cold water line as specified under Closed System Thermal Expansion 5 Install a shut off valve in the cold water inlet line It should be...

Страница 7: ... other methods to control this situation IMPORTANT Do not plug or remove the temperature and pressure relief valve Closed System Thermal Expansion For protection against excessive pressures and temperatures a temperature and pressure relief valve must be installed in the opening marked T P RELIEF VALVE See Figure 9 CAUTION To reduce the risk of excessive pressures and temperatures in this water he...

Страница 8: ...drain or external to the building Shall be of material listed for hot water distribution Shall be installed to allow complete drainage of both the valve and discharge line Solar Installation If this water heater is used as a solar storage heater or as a backup for the solar system the inlet water supply temperatures to the water heater tank may be in excess of 120 F A tempering valve or other temp...

Страница 9: ...ch continues to shut off the water heater contact a qualified person for service Water Temperature Regulation Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded Feel water before bathing or showering Temperature limiting valves are available WARNING The thermostat is adjusted to a temperature setting ...

Страница 10: ...ed person 1 Disconnect the electric power 2 Remove the access cover s and fold up the insulation from the thermostat s Do not remove the plastic cover 3 Using a screwdriver to adjust the thermostat pointer set the thermostat s to the desired water temperature Be sure the RED reset button High Limit Control is pushed in If needed push in firmly to reset 4 Fold the insulation down making sure the th...

Страница 11: ...d be replaced NOTE Whether reinstalling or replacing the anode rod check for any leaks and immediately correct if found In replacing the anode 1 Turn off power to the water heater 2 Shut off the water supply and open a nearby hot water faucet to depressurize the water tank 3 Drain approximately 5 gallons of water from tank Refer to the Draining and Flushing section for proper procedures Close drai...

Страница 12: ... Flush the tank with water as needed to remove sediment 6 Close the drain valve and completely refill the water heater tank 7 Reconnect electrical power to the water heater If the water heater is going to be shut down for an extended period the drain valve should be left open Heating Element Replacement WARNING Electric Shock Hazard Disconnect power before servicing Replace all parts and panels be...

Страница 13: ... for source of trouble and correct 3 Replace thermostat INSUFFICIENT HOT WATER 1 Non Functioning thermostats 2 Non Functioning lower element 3 Improper calibration 4 Thermostats set too low 5 Sediment or lime in tank 6 Heater too small for job 7 Wrong piping connections 8 Leaking faucets 9 Wasted hot water 10 Long runs of exposed pipe 11 Hot water piping on outside wall 1 Replace thermostats 2 Rep...

Страница 14: ...RAIN VALVE REPAIR PARTS Repair parts may be ordered through your plumber local distributor home improvement center or by calling 1 877 817 6750 When ordering repair parts always give the following information 1 Model serial and product number 2 Item number 3 Parts description REPAIR PARTS LIST LEGEND Special anode rod See Anode Rod Water Odor section Temperature and Pressure Relief Valve is requir...

Страница 15: ...GH LIMIT CONTROL WIRING NO 7 SINGLE ELEMENT HEATER D E R HEATING ELEMENT GROUND SCREW ELECTRICAL SERVICE GROUND 120 V 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 9000 12000 15 20 30 30 WATT LOAD BRANCH CIRCUIT SIZING GUIDE Based on N E C NFPA NO 70 1999 15 15 15 20 20 25 30 30 35 35 50 70 15 15 15 15 20 20 25 30 30 30 45 60 208 V 240 V Recommend Over Current Protection Rating 12 10 10 8 14 1...

Страница 16: ...16 ...

Отзывы: