Devices for Hot Water Supply Systems, ANSI Z21.22 - 
latest edition. This valve must be marked with the maximum 
set pressure not to exceed the marked maximum working 
pressure of the water heater. Install the valve into an 
opening provided and marked for this purpose in the water 
heater, and orient it or provide tubing so that any discharge 
from the valve exits only within 6 inches above, or at any 
distance below, the structural fl oor, and does not contact 
any live electrical part. The discharge opening must not be 
blocked or reduced in size under any circumstance. 

IMPORTANT:  Only a new temperature and pressure relief 
valve should be used with your water heater. Do not use an 
old or existing valve as it may be damaged or not adequate 
for the working pressure of the new water heater. Do not 
place any valve between the relief valve and the tank.

The Temperature & Pressure Relief Valve:   

• 

Shall not be in contact with any electrical part.

• 

Shall be connected to an adequate discharge line.

• 

Shall not be rated higher than  the working pressure  
shown on the data plate of the water heater.

The Discharge Line:

• 

Shall not be smaller than the pipe size of the relief  
valve or have any reducing coupling installed in the 
discharge line.

• 

Shall not be capped, blocked, plugged or contain    
any valve between the relief valve and the end of the 
discharge line.

• 

Shall terminate a maximum of 6 inches above a floor 
drain or external to the building.

• 

Shall be of material listed for hot water distribution.

• 

Shall be installed to allow complete drainage of both 
the valve and discharge line.

Solar Installation

If this water heater is used as a solar storage heater or 
as a backup for the solar system, the inlet water supply 
temperatures to the water heater tank may be in excess of 
120°F. A tempering valve or other temperature limiting valve 
must be installed in the inlet water supply line to limit the 
supply temperature to 120°F.

NOTE: Solar water heating systems can often supply water 
with temperatures exceeding 180°F and may result in water 
heater malfunction.

Water Heater Location

  Centrally located with the water piping system.

  Located indoors and in a vertical position. Protected  

from freezing temperatures.

  Provisions made to protect the area from water    

damage. Metal drain pan installed and piped to an 
adequate drain.

  Sufficient room to service the water heater.

Water System Piping

  Temperature and pressure relief valve properly    

installed with a discharge line run to an open drain  
and protected from freezing.

  All piping properly installed and free of leaks.

  Heater completely filled with water. (See Figure 2)

  Closed system pressure buildup precautions    

installed.

  Tempering valve (when applicable) installed per 

manufacturer’s instructions (see “Water Temperature 
Regulation” section).

Electrical Connections

  Wiring and connections comply with all applicable  

codes.

  Water heater and electrical supply are properly    

grounded.

  Proper overload fuse or circuit breaker protection  

installed.

INSTALLATION
CHECKLIST

Содержание 121802

Страница 1: ... 4 Date of installation 5 Place of Purchase Water Heater Safety 2 Installing Your Water Heater 3 8 Unpacking Instructions 3 Location Requirements 4 Electrical Requirements 5 Water System Piping 6 Installation Checklist 8 Operating Your Water Heater 9 11 Water Temperature Regulation 9 Adjusting the Thermostat High Limit Control 10 Operational Conditions 11 Maintenance of Your Water Heater 12 13 Tro...

Страница 2: ...s not been used for a long period of time 2 weeks or more Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system When hydrogen is present there will probably be an unusual sound such as air escaping thr...

Страница 3: ...is manual If you lack the necessary skills required to properly install this water heater or you have difficulty following the directions you should not proceed but have a qualified person perform the installation of this water heater Examples of a qualified person include licensed plumbers authorized gas company personnel and authorized service personnel Massachusetts code requires this water heate...

Страница 4: ...any external plumbing leak including those from improper installation may cause early failure of the tank due to corrosion if not repaired If the owner operator is uncomfortable with making the repair a qualified person should be contacted A suitable metal drain pan should be installed under the water heater as shown below to help protect the property from damage which may occur from condensate fo...

Страница 5: ...the electrical supply to the water heater A standard 1 2 inch opening has been made in the junction box for conduit connections 5 Connect ground wire to green ground screw in the junction box of the water heater Reinstall the junction box cover Figure 3 120 240V 2 Wire Models Junction Box Cover Ground Wire Conduit White Wire 120V Models Red Wire 240V Models Black Wire Green Ground Screw Black Whit...

Страница 6: ...nt of use temperature of the hot water by mixing cold and hot water and are readily available Contact a licensed plumber or the local plumbing authority for more information 4 If installing the water heater in a closed water system install an expansion tank in the cold water line as specified under Closed System Thermal Expansion 5 Install a shut off valve in the cold water inlet line It should be...

Страница 7: ... other methods to control this situation IMPORTANT Do not plug or remove the temperature and pressure relief valve Closed System Thermal Expansion For protection against excessive pressures and temperatures a temperature and pressure relief valve must be installed in the opening marked T P RELIEF VALVE See Figure 9 CAUTION To reduce the risk of excessive pressures and temperatures in this water he...

Страница 8: ...drain or external to the building Shall be of material listed for hot water distribution Shall be installed to allow complete drainage of both the valve and discharge line Solar Installation If this water heater is used as a solar storage heater or as a backup for the solar system the inlet water supply temperatures to the water heater tank may be in excess of 120 F A tempering valve or other temp...

Страница 9: ...ch continues to shut off the water heater contact a qualified person for service Water Temperature Regulation Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded Feel water before bathing or showering Temperature limiting valves are available WARNING The thermostat is adjusted to a temperature setting ...

Страница 10: ...ed person 1 Disconnect the electric power 2 Remove the access cover s and fold up the insulation from the thermostat s Do not remove the plastic cover 3 Using a screwdriver to adjust the thermostat pointer set the thermostat s to the desired water temperature Be sure the RED reset button High Limit Control is pushed in If needed push in firmly to reset 4 Fold the insulation down making sure the th...

Страница 11: ...d be replaced NOTE Whether reinstalling or replacing the anode rod check for any leaks and immediately correct if found In replacing the anode 1 Turn off power to the water heater 2 Shut off the water supply and open a nearby hot water faucet to depressurize the water tank 3 Drain approximately 5 gallons of water from tank Refer to the Draining and Flushing section for proper procedures Close drai...

Страница 12: ... Flush the tank with water as needed to remove sediment 6 Close the drain valve and completely refill the water heater tank 7 Reconnect electrical power to the water heater If the water heater is going to be shut down for an extended period the drain valve should be left open Heating Element Replacement WARNING Electric Shock Hazard Disconnect power before servicing Replace all parts and panels be...

Страница 13: ... for source of trouble and correct 3 Replace thermostat INSUFFICIENT HOT WATER 1 Non Functioning thermostats 2 Non Functioning lower element 3 Improper calibration 4 Thermostats set too low 5 Sediment or lime in tank 6 Heater too small for job 7 Wrong piping connections 8 Leaking faucets 9 Wasted hot water 10 Long runs of exposed pipe 11 Hot water piping on outside wall 1 Replace thermostats 2 Rep...

Страница 14: ...RAIN VALVE REPAIR PARTS Repair parts may be ordered through your plumber local distributor home improvement center or by calling 1 877 817 6750 When ordering repair parts always give the following information 1 Model serial and product number 2 Item number 3 Parts description REPAIR PARTS LIST LEGEND Special anode rod See Anode Rod Water Odor section Temperature and Pressure Relief Valve is requir...

Страница 15: ...GH LIMIT CONTROL WIRING NO 7 SINGLE ELEMENT HEATER D E R HEATING ELEMENT GROUND SCREW ELECTRICAL SERVICE GROUND 120 V 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 9000 12000 15 20 30 30 WATT LOAD BRANCH CIRCUIT SIZING GUIDE Based on N E C NFPA NO 70 1999 15 15 15 20 20 25 30 30 35 35 50 70 15 15 15 15 20 20 25 30 30 30 45 60 208 V 240 V Recommend Over Current Protection Rating 12 10 10 8 14 1...

Страница 16: ...16 ...

Отзывы: