6

Water System Piping

Piping, fi ttings, and valves should be installed according to 
the installation drawing (Figure 6). If the indoor installation 
area is subject to freezing temperatures, the water piping 
must be properly insulated. 
Water supply pressure should not exceed 80% of the 
working pressure of the water heater. The working 
pressure is stated on the water heater’s data plate. If this 
occurs a pressure limiting valve with a bypass may need 
to be installed in the cold water supply line. This should 
be placed on the supply to the entire house in order to 
maintain equal hot and cold water pressures.
IMPORTANT: 
• 

Heat must not be applied to the water fittings on the 
heater as they may contain nonmetallic parts. If solder 
connections are used, solder the pipe to the adapter 
before attaching the adapter to the hot and cold water 
fittings. 

• 

Always use a good grade of joint compound and be 
certain that all fittings are tight.

Piping Installation

1.  Install the water piping and fittings as shown in  Figure 

6. Connect the cold water supply (3/4” NPT)  to the 
fitting marked “C”. Connect the hot water supply (3/4” 
NPT)  to the fitting marked “H”.

 

IMPORTANT:  Some models may contain energy sav-
ing heat traps to prevent the circulation of hot water 
within the pipes. Do not remove these inserts.

2.  The installation of unions in both the hot and cold    

water supply lines are recommended for ease of    
removing the water heater for service or replacement.

3.  Some local codes may require, and the manufacturer 

of this water heater recommends, installing a tempering 
valve or an anti-scald device in the domestic hot water 
line as shown in Figures 7 and 8. These valves reduce  
the point-of-use temperature of the hot water by mixing 
cold and hot water and are readily available. Contact 
a licensed plumber or the local plumbing authority for 
more information.

4.  If installing the water heater in a closed water system,   

install an expansion tank in the cold water line as 
specified under “Closed System/Thermal Expansion.”

5.

 

Install a shut off valve in the cold water inlet line. It   
should be located close to the water heater and be    
easily accessible. Know the location of this valve and  
how to shut off the water to the heater.

6.

 

Install a temperature and pressure relief valve and  
discharge line in the opening marked “T & P RELIEF  
VALVE”. Install as specified under “Temperature and   
Pressure Relief Valve.” 

7.  After piping has been properly connected to the water  

heater, open the nearest hot water faucet and allow  
the tank to completely fill with water. To purge the    
lines of any excess air and sediment, keep the hot   
water faucet open for 3 minutes after a constant flow  
of water is obtained. Close the faucet and check all  
connections for leaks. 

Figure 7
Tempering Valve
Side Water Connections

Follow The Tempering
Valve’s Manufacturer’s
Installation Instructions

Tempered
Water

Hot
Water Out

Cold Water In

Tempering Valve

Set To 120° F Maximum

Figure 8
Tempering Valve
Top Water Connections

Follow the tempering 
valve manufacturer’s 
instructions

Cold
Water
Inlet

Hot
Water
Outlet

Tempered
Water To
Fixtures

Tempering Valve

(Set To 120°  F)

In a closed system use a 
thermal expansion tank.

Pressure
Reducing

Cold Water 

Inlet

Cold Water 
Inlet Valve

Hot 

Water
Outlet

Union

Temperature And
Pressure Relief Valve

Discharge Line
6 Inches Maximum
Above Drain

Drain Line
3/4 Inch ID
Minimum

Drain

Drain Pan
2-1/2 Inch Depth Maximum

1 Inch
Minimum

Massachusetts:  Install a 
vacuum relief in cold water
line per section 19 MGL 142.

Figure 6
Water Piping Installation

Содержание 121802

Страница 1: ... 4 Date of installation 5 Place of Purchase Water Heater Safety 2 Installing Your Water Heater 3 8 Unpacking Instructions 3 Location Requirements 4 Electrical Requirements 5 Water System Piping 6 Installation Checklist 8 Operating Your Water Heater 9 11 Water Temperature Regulation 9 Adjusting the Thermostat High Limit Control 10 Operational Conditions 11 Maintenance of Your Water Heater 12 13 Tro...

Страница 2: ...s not been used for a long period of time 2 weeks or more Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system When hydrogen is present there will probably be an unusual sound such as air escaping thr...

Страница 3: ...is manual If you lack the necessary skills required to properly install this water heater or you have difficulty following the directions you should not proceed but have a qualified person perform the installation of this water heater Examples of a qualified person include licensed plumbers authorized gas company personnel and authorized service personnel Massachusetts code requires this water heate...

Страница 4: ...any external plumbing leak including those from improper installation may cause early failure of the tank due to corrosion if not repaired If the owner operator is uncomfortable with making the repair a qualified person should be contacted A suitable metal drain pan should be installed under the water heater as shown below to help protect the property from damage which may occur from condensate fo...

Страница 5: ...the electrical supply to the water heater A standard 1 2 inch opening has been made in the junction box for conduit connections 5 Connect ground wire to green ground screw in the junction box of the water heater Reinstall the junction box cover Figure 3 120 240V 2 Wire Models Junction Box Cover Ground Wire Conduit White Wire 120V Models Red Wire 240V Models Black Wire Green Ground Screw Black Whit...

Страница 6: ...nt of use temperature of the hot water by mixing cold and hot water and are readily available Contact a licensed plumber or the local plumbing authority for more information 4 If installing the water heater in a closed water system install an expansion tank in the cold water line as specified under Closed System Thermal Expansion 5 Install a shut off valve in the cold water inlet line It should be...

Страница 7: ... other methods to control this situation IMPORTANT Do not plug or remove the temperature and pressure relief valve Closed System Thermal Expansion For protection against excessive pressures and temperatures a temperature and pressure relief valve must be installed in the opening marked T P RELIEF VALVE See Figure 9 CAUTION To reduce the risk of excessive pressures and temperatures in this water he...

Страница 8: ...drain or external to the building Shall be of material listed for hot water distribution Shall be installed to allow complete drainage of both the valve and discharge line Solar Installation If this water heater is used as a solar storage heater or as a backup for the solar system the inlet water supply temperatures to the water heater tank may be in excess of 120 F A tempering valve or other temp...

Страница 9: ...ch continues to shut off the water heater contact a qualified person for service Water Temperature Regulation Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded Feel water before bathing or showering Temperature limiting valves are available WARNING The thermostat is adjusted to a temperature setting ...

Страница 10: ...ed person 1 Disconnect the electric power 2 Remove the access cover s and fold up the insulation from the thermostat s Do not remove the plastic cover 3 Using a screwdriver to adjust the thermostat pointer set the thermostat s to the desired water temperature Be sure the RED reset button High Limit Control is pushed in If needed push in firmly to reset 4 Fold the insulation down making sure the th...

Страница 11: ...d be replaced NOTE Whether reinstalling or replacing the anode rod check for any leaks and immediately correct if found In replacing the anode 1 Turn off power to the water heater 2 Shut off the water supply and open a nearby hot water faucet to depressurize the water tank 3 Drain approximately 5 gallons of water from tank Refer to the Draining and Flushing section for proper procedures Close drai...

Страница 12: ... Flush the tank with water as needed to remove sediment 6 Close the drain valve and completely refill the water heater tank 7 Reconnect electrical power to the water heater If the water heater is going to be shut down for an extended period the drain valve should be left open Heating Element Replacement WARNING Electric Shock Hazard Disconnect power before servicing Replace all parts and panels be...

Страница 13: ... for source of trouble and correct 3 Replace thermostat INSUFFICIENT HOT WATER 1 Non Functioning thermostats 2 Non Functioning lower element 3 Improper calibration 4 Thermostats set too low 5 Sediment or lime in tank 6 Heater too small for job 7 Wrong piping connections 8 Leaking faucets 9 Wasted hot water 10 Long runs of exposed pipe 11 Hot water piping on outside wall 1 Replace thermostats 2 Rep...

Страница 14: ...RAIN VALVE REPAIR PARTS Repair parts may be ordered through your plumber local distributor home improvement center or by calling 1 877 817 6750 When ordering repair parts always give the following information 1 Model serial and product number 2 Item number 3 Parts description REPAIR PARTS LIST LEGEND Special anode rod See Anode Rod Water Odor section Temperature and Pressure Relief Valve is requir...

Страница 15: ...GH LIMIT CONTROL WIRING NO 7 SINGLE ELEMENT HEATER D E R HEATING ELEMENT GROUND SCREW ELECTRICAL SERVICE GROUND 120 V 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 9000 12000 15 20 30 30 WATT LOAD BRANCH CIRCUIT SIZING GUIDE Based on N E C NFPA NO 70 1999 15 15 15 20 20 25 30 30 35 35 50 70 15 15 15 15 20 20 25 30 30 30 45 60 208 V 240 V Recommend Over Current Protection Rating 12 10 10 8 14 1...

Страница 16: ...16 ...