To confirm that the factory defaults have 
been restored,

 

LED 3 on the Arrow indicator 

will light up for 

two seconds

.

After the 2 seconds pass, all of the indicator lights will turn off and the 
factory defaults will be stored. This will put the unit back into lighting 
operating mode, and the lighting defaults can be tested.

NOTE: The siren defaults cannot be tested until the unit is out of 
programming mode (i.e. all dip switches ON)

(4) Activating the Siren:

Any of the 11 lighting control switches can be configured to activate the 
siren into the HF mode.

Factory Default: 

Slide Switch Position 3

To activate the siren from a lighting switch:

(DIP SWITCH SETTING:

 SWITCH 1, 2 & 3 ON  /  SWITCH 4 OFF)

1. Put the unit into “Siren Activation” mode:

• Place the SLIDE SWITCH in the OFF position (all the way to the left) 

and turn all Momentary switches off.

• Press and hold the RADIO switch.
• Press and release momentary switch 7.
• Release the RADIO switch.

To confirm entry into this configuration 
mode, LED 4 on the Arrow indicator will light 
up.

AND…

All switch indicator lights whose corresponding switch is already 
programmed to activate the Siren will turn on steady.

2. Add or Delete switches:

To select a momentary switch:

• Press and release one of the 8 momentary switches to add or delete it 

from activating the siren. The switches indicator light will turn on steady 
when its corresponding switch is selected.

OR...

To select a slide switch position:

• Move the slide switch to the position that you wish to activate the siren.
• Press and release the MANUAL switch, the slide switches indicator light 

will turn on steady when its switch position has been selected.

3. Store and activate the selected switch's:

• Place the SLIDE SWITCH in the OFF position.
• Press and release the RADIO switch.

All of the indicator lights will turn off and the data will be stored. This will 
put the unit back into lighting operating mode.

NOTE: This change cannot be tested until the unit is out of 
programming mode (i.e. all dip switches ON)

(5) Deactivating the Siren:

Any of the 11 lighting control

 

switches can be configured to deactivate the 

siren out of HF mode.

Factory Default: 

Slide Switch Positions 1, 2

To deactivate the siren from a lighting switch:

(

DIP SWITCH SETTING:

 SWITCH 1, 2 & 3 ON  /  SWITCH 4 OFF)

1. Put the unit into “Siren Deactivation” mode:

• Place the SLIDE SWITCH in the OFF position (all the way to the left) 

and turn all Momentary switches off.

• Press and hold the RADIO switch.
• Press and release momentary switch 11.
• Release the RADIO switch.

To confirm entry into this configuration 
mode, LEDS 2 and 3 on the Arrow indicator 
will light up.

AND…

All switch indicator lights whose corresponding switch is already 
programmed to deactivate the Siren will turn on steady.

2. Add or Delete switches:

To select a momentary switch:

• Press and release one of the 8 momentary switches to add or delete it 

from deactivating the siren. The switches indicator light will turn on 
steady when its corresponding switch is selected.

OR...

To select a slide switch position:

• Move the slide switch to the position that you wish to deactivate the 

siren.

• Press and release the MANUAL switch, the slide switches indicator light 

will turn on steady when its switch position has been selected.

3. Store and activate the selected switch's:

• Place the SLIDE SWITCH in the OFF position.
• Press and release the RADIO switch.

All of the indicator lights will turn off and the data will be stored. This will 
put the unit back into lighting operating mode.

NOTE “A”: This change cannot be tested until the unit is out of 
programming mode (i.e. all dip switches ON)

NOTE “B”: When slide switch positions are used to deactivate the 
siren from HF mode, deactivation will only take place when the slide 
switch is moved out of a position that was programmed to activate 
the siren.

(6) Remote Activation of the 8 Momentary 
switches:

Any of the 11 lighting control switches can be configured to remotely 
activate any of the 8 momentary lighting control switches.

Factory Default

: No momentary switches are remotely activated.

(

DIP SWITCH SETTING:

 SWITCH 1, 2 & 3 ON  /  SWITCH 4 OFF)

To activate Momentary Switches:

1. Put the unit into Momentary Switch Activation Mode:

• Place the SLIDE SWITCH in the OFF position and turn all momentary 

switches off.

• Press and hold the RADIO switch.
• Press and release momentary switch 8.
• Release the RADIO switch.

To confirm entry into this configuration 
mode, 

LED 5 on the Arrow indicator will

light up.

2. Select a switch to be configured:

To select a momentary switch:

• Press and release the momentary switch that you wish to configure.

OR...

To select a slide switch position:

• Move the slide switch to the position that you wish to activate the siren.
• Press and release the MANUAL switch.

All switch indicator lights whose corresponding switch is already 
programmed to be activated by the selected Switch will turn on 
steady.

Содержание 295SDA1

Страница 1: ...mounting location based on providing ultimate safety to all passengers inside the vehicle For this product to operate at optimum efficiency a good electrical connection to chassis ground must be made...

Страница 2: ...e unit IMPORTANT The 295SDA1 case must be either mounted on or grounded to the vehicle chassis Control Head There are two basic mounting brackets for the 295SDA1 control head One allows the control he...

Страница 3: ...ttery Splice the 2 BLACK Ground wires together and extend this single BLACK wire toward the vehicle battery To pass the RED and BLACK wires through you may have to drill a hole in the firewall Insert...

Страница 4: ...until released Activating the RADIO WAIL TONE3 or STANDBY button will deactivate the YELP button and produce their corresponding function Activating the HORN RING input or MAN button will change the s...

Страница 5: ...rammed as a Traffic Advisor Pattern Control switch If more than one switch is programmed unpredictable results will occur When a switch s Switch Type has been programmed as Traffic Advisor Flash Contr...

Страница 6: ...ches off Press and hold the RADIO switch Press and release momentary switch 4 Release the RADIO switch To confirm entry into this configuration mode LED 1 on the Arrow indicator will light up 2 Select...

Страница 7: ...WITCH in the OFF position all the way to the left and turn all Momentary switches off Press and hold the RADIO switch Press and release momentary switch 11 Release the RADIO switch To confirm entry in...

Страница 8: ...E If the right slide switch indicator light on the secondary unit turns on an error has occurred press the RADIO on both units to start back at step 1 5 Store and activate the configuration Press and...

Страница 9: ...IL switch Press and release momentary switch 8 Release the WAIL switch To confirm entry into Shutdown Delay adjustment mode the Arrow indicator will display this pattern arrow leds 2 4 2 To adjust the...

Страница 10: ...he tone for the MANUAL and AIRHORN switch Press and hold the MANUAL or AIRHORN switch Press and release the lighting momentary switch 4 to change the tone produced by speaker 1 OR Press and release th...

Отзывы: