Wheaton UniSpense ELITE Скачать руководство пользователя страница 4

WHEATON UniSpense

®

 PRO Peristaltic Pump 

 

 

 

 

 

WHEATON  | 800.225.1437 (U.S. & Canada Only) | 856.825.1100 | www.wheatonsci.com| P/N 50099073 Rev. 2/2/10 Lit. No.8734 

 

General Safety Rules 

 

WARNING. READ AND UNDERSTAND ALL INSTRUCTIONS. 

Failure to follow all 

instructions listed below may result in electrical shock, fire and / or serious personal injury. 

SAVE THESE INSTRUCTIONS 

1.  Know your instrument

 - Read the operating manual carefully. Learn the equipment's application and 

limitations. 

2.  Ground all equipment

 - If electrical, this instrument is equipped with a grounding type plug. The 

green/yellow conductor in the cord is the grounding wire and should never be connected to a live 
terminal. 

3.  Avoid dangerous environment

 - Electrical instruments designed to process liquids must be operated 

with extreme caution. If liquid comes in contact with internal electrical components or wires, fire or 
electrical shock may occur. Adequate surrounding work space should be provided during use. Do not 
operate electrical instrumentation in a combustible atmosphere. 

4.  Work surface

 - Keep well lighted. Be certain the work surface is clean, level and sturdy enough to 

support the weight of the unit, particularly if it is to be filled with liquid. 

5.  Wear proper apparel -

 Do not wear loose clothing, neckties or jewelry that might get caught in moving 

parts. Non-slip footwear is recommended. Wear protective hair covering to contain long hair. 

6.  Wear safety goggles 

- Wear safety goggles at all times. Everyday eyeglasses only have impact 

resistant lenses, they are NOT safety glasses. 

7.    Don’t Overreach 

- Keep proper footing and balance at all times.

 

8.    Maintain instrument with care 

- Keep screws tight and unit clean. Check periodically for worn or 

damaged parts. Inspect the plug and cord before each use. Do not operate this instrument if there are 
signs of damage. 

9.    Avoid accidental start up 

- If electrical, always make sure the switch is in the "OFF" position before 

plugging instrument into outlet. 

10. Disconnect Instrument 

- Always disconnect the instrument from the power source before servicing. 

11. Do not block cooling vents if provided. 

12. Do not operate this equipment in any manner not specified in this manual.  

13.  It is recommended that a fire extinguisher always be located in areas where electrical 

instruments are being used. 

Specific Safety Considerations 

 

 

WARNING !  IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.  IN THE 
EVENT  OF  A  SHORT  CIRCUIT,  GROUNDING  REDUCES  THE  RISK  OF  SHOCK.      THIS 
INSTRUMENT MUST BE GROUNDED.

 

 

This instrument is equipped with a cord having a grounding wire and an appropriate grounding plug.  The 
plug must be used with an outlet that has been installed and grounded in accordance with all local codes 
and ordinances. The outlet must have the same configuration as the plug.  

DO NOT USE AN ADAPTER.

 

Do  not  modify  the  line  cord  that  has  been  provided.    If  it  does  not  fit  the  available  outlet,  contact  your 
nearest WHEATON Industries distributor for the proper line cord for your geographic area. 
 

 

Содержание UniSpense ELITE

Страница 1: ...heatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 Catalog Numbers W375040 A and W375040 B 100 120V and W375040 C through W375040 J 220 240V WHEATON UniSpense PRO Peristaltic Pump Instruction Manual In...

Страница 2: ...tch Operation and Connector Functions 7 6 Flexible Tubing Holder 8 0 Unit Setup 8 1 Language Selection 8 2 Buzzer Function 8 3 Unit Reset 9 0 Preparing for Batch and Single Dose Dispensing 10 0 Making...

Страница 3: ...s of identifying such a problem by calling Customer Service at 800 225 1437 U S Puerto Rico and Canada or Internationally at 856 825 1100 and then providing the Model Serial and Catalog Number of the...

Страница 4: ...ain long hair 6 Wear safety goggles Wear safety goggles at all times Everyday eyeglasses only have impact resistant lenses they are NOT safety glasses 7 Don t Overreach Keep proper footing and balance...

Страница 5: ...te Ranges For Various Tubing Sizes 3 2 0mm ID 0 5 mL sec and 1 0 mL sec 3 0mm ID 1 0 mL sec and 2 0 mL sec 6 0mm ID 3 5 mL sec and 7 1 mL sec 8 0mm ID 5 6 mL sec and 11 2 mL sec Vertical Head Height A...

Страница 6: ...hed Retain packaging until all parts and unit functionality are confirmed Components Supplied UniSpense PRO peristaltic pump Pump Head Line Cord supplied to fit your local electrical outlet specificat...

Страница 7: ...e selected set ups can be stored in memory and quickly retrieved for later use Selections stored in memory are preserved even after powering the unit down Pump speed is selectable at 75 and 150 RPM A...

Страница 8: ...kinks CAUTION Improper adjustment of the tubing clamps may result in improper performance of tubing or premature wear and failure of tubing DOUBLE CHECK clamp settings before proceeding To Remove Pump...

Страница 9: ...pad Functions and Icons Icons on the right of each screen show the user which keys will be active during function and setup navigation A brief explanation of active keys is listed Help Pushing the hel...

Страница 10: ...or a Pump Running Pump Stopped indicator Pins 1 footswitch and 2 footswitch GND are 5V TTL compatible inputs with pull up resistors and can be driven by an isolated open collector device or dry contac...

Страница 11: ...ispense alert Turning the buzzer function OFF shown will disable the buzzer during the dispense cycle 8 3 Unit Reset Press the UP and DOWN and the LEFT and RIGHT keys to access the Unit Reset Function...

Страница 12: ...ate to the CALIBRATE screen 10 1 Setting Operating Speed Use the LEFT and RIGHT buttons to select the calibration speed Set the Calibration Speed so that the pump runs for at least 15 seconds during t...

Страница 13: ...e Use the UP and DOWN button to navigate the Calibration Dispense icon Prepare to measure a dispense by using a graduated cylinder electronic scale or other device that can accurately measure volume P...

Страница 14: ...nd DOWN and the LEFT and RIGHT keys to enter the batch count Press OK when done Entering 1 will provide a single dispense 11 2 Volume per Dispense Use the UP and DOWN keys to navigate to the Volume pe...

Страница 15: ...and RIGHT keys to enter the dispense volume Press OK when done Press the Start Stop button to resume batch dispensing 11 6 To Run Additional Batches with the Same Settings Press the Start Stop button...

Страница 16: ...storage of parameters If parameters are stored in a register already containing data the old data will be overwritten with the new parameters 12 2 To Recall a Parameter Press the UP and DOWN and the...

Страница 17: ...n of the tubing assembly for excessive wear and leaks Many service problems can often be cured by simply replacing a worn tubing assembly To insure high accuracy the pump rotor and tubing clamping mec...

Страница 18: ...pump motor speed as required Cause Motor control board defective Remedy Replace defective board Cause START Key not pressed Remedy See Unit Features and Component Identification for keypad and displa...

Страница 19: ...Thickness mismatch with pump head used Remedy Tubing wall weight should match pump head specifications Inaccurate Volume Delivery Cause Tubing assembly worn Remedy Replace tubing assembly Cause Pump...

Страница 20: ...IS DISCONNECTED FROM THE AC POWER SOURCE 1 Disconnect the cord set from the AC power source 2 Remove the fuse drawer by using a small flat screwdriver to lift the tab 3 Replace with new fuses 108 120...

Страница 21: ...p WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 21 FIGURE A Major Component Identification Display Screen Keypad Pump Head I O Interface Conn...

Страница 22: ...STAR 6 INT TOOTH 17 1 50099063 STF 6 32 X 1 4 ALUMINUM 18 2 WI056864 FUSE 5X20MM 2 0AT 250V 120V 18 2 WI056862 FUSE 5X20MM 1 0AT 250V FIGURES C THRU E Upper Housing Assembly Main Assembly and Wiring D...

Страница 23: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 23...

Страница 24: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 24...

Страница 25: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 25...

Страница 26: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 26...

Страница 27: ...WHEATON UniSpense PRO Peristaltic Pump WHEATON 800 225 1437 U S Canada Only 856 825 1100 www wheatonsci com P N 50099073 Rev 2 2 10 Lit No 8734 27...

Страница 28: ...arations of Conformity and WEEE Statement WEEE STATEMENT This UniSpense PRO peristaltic pump is not to be discarded in typical trash outlets This unit is to be discarded according to WEEE guidelines e...

Страница 29: ...quirements specified by the appropriate EU Directive with respect to the design and construction of the commercialized version This declaration is invalid if modifications are performed on the device...

Отзывы: